ترغب بنشر مسار تعليمي؟ اضغط هنا

A high precision calibration of the nonlinear energy response at Daya Bay

81   0   0.0 ( 0 )
 نشر من قبل Zeyuan Yu
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

A high precision calibration of the nonlinearity in the energy response of the Daya Bay Reactor Neutrino Experiments antineutrino detectors is presented in detail. The energy nonlinearity originates from the particle-dependent light yield of the scintillator and charge-dependent electronics response. The nonlinearity model is constrained by $gamma$ calibration points from deployed and naturally occurring radioactive sources, the $beta$ spectrum from $^{12}$B decays, and a direct measurement of the electronics nonlinearity with a new flash analog-to-digital converter readout system. Less than 0.5% uncertainty in the energy nonlinearity calibration is achieved for positrons of kinetic energies greater than 1 MeV.

قيم البحث

اقرأ أيضاً

80 - J. Liu , B. Cai , R. Carr 2013
We describe the automated calibration system for the antineutrino detectors in the Daya Bay Neutrino Experiment. This system consists of 24 identical units instrumented on 8 identical 20-ton liquid scintillator detectors. Each unit is a fully automat ed robotic system capable of deploying an LED and various radioactive sources into the detector along given vertical axes. Selected results from performance studies of the calibration system are reported.
This paper describes in detail the acrylic target vessels used to encapsulate the target and gamma catcher regions in the Daya Bay experiments first pair of antineutrino detectors. We give an overview of the design, fabrication, shipping, and install ation of the acrylic target vessels and their liquid overflow tanks. The acrylic quality assurance program and vessel characterization, which measures all geometric, optical, and material properties relevant to { u}e detection at Daya Bay are summarized. This paper is the technical reference for the Daya Bay acrylic vessels and can provide guidance in the design and use of acrylic components in future neutrino or dark matter experiments.
The Daya Bay Reactor Neutrino Experiment has measured the last unknown neutrino mixing angle, {theta}13, to be non-zero at the 7.7{sigma} level. This is the most precise measurement to {theta}13 to date. To further enhance the understanding of the re sponse of the antineutrino detectors (ADs), a detailed calibration of an AD with the Manual Calibration System (MCS) was undertaken during the summer 2012 shutdown. The MCS is capable of placing a radioactive source with a positional accuracy of 25 mm in R direction, 20 mm in Z axis and 0.5{deg} in {Phi} direction. A detailed description of the MCS is presented followed by a summary of its performance in the AD calibration run.
The Daya Bay Experiment consists of eight identically designed detectors located in three underground experimental halls named as EH1, EH2, EH3, with 250, 265 and 860 meters of water equivalent vertical overburden, respectively. Cosmic muon events ha ve been recorded over a two-year period. The underground muon rate is observed to be positively correlated with the effective atmospheric temperature and to follow a seasonal modulation pattern. The correlation coefficient $alpha$, describing how a variation in the muon rate relates to a variation in the effective atmospheric temperature, is found to be $alpha_{text{EH1}} = 0.362pm0.031$, $alpha_{text{EH2}} = 0.433pm0.038$ and $alpha_{text{EH3}} = 0.641pm0.057$ for each experimental hall.
92 - Wenqi Yan , Tao Hu , Li Zhou 2020
The Jiangmen Underground Neutrino Observatory (JUNO), a multi-purpose neutrino experiment, will use 20 kt liquid scintillator (LS). To achieve the physics goal of determining the neutrino mass ordering, 3$%$ energy resolution at 1 MeV is required. Th is puts strict requirements on the LS light yield and the transparency. Four LS purification steps have been designed and mid-scale plants have been built at Daya Bay. To examine the performance of the purified LS and find the optimized LS composition, the purified LS was injected to the antineutrino detector 1 in the experimental hall 1 (EH1-AD1) of the Daya Bay neutrino experiment. To pump out the original gadolinium loaded LS and fill the new LS, a LS replacement system has been built in EH1 in 2017. By replacing the Gd-LS with purified water, then replacing the water with purified LS, the replacement system successfully achieved the designed goal. Subsequently, the fluorescence and the wavelength shifter were added to higher concentrations via the replacement system. The data taken at various LS compositions helped JUNO determine the final LS cocktail. Details of the design, the construction, and the operation of the replacement system are reported in this paper.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا