ترغب بنشر مسار تعليمي؟ اضغط هنا

First Imaging Results of a Bubble-assisted Liquid Hole Multiplier with SiPM readout in Liquid Xenon

89   0   0.0 ( 0 )
 نشر من قبل Eran Erdal
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

First imaging results in liquid xenon of a Liquid Hole Multiplier (LHM) coupled to a Quad-Silicon Photomultiplier (SiPM) array are presented. Ionization electrons deposited in the noble liquid by 5.5 MeV alpha particles, are collected into the holes of a Thick Gas Electron Multiplier (THGEM) electrode having a xenon gas bubble trapped underneath. They drift through the liquid-gas interface, inducing electroluminescence within the bubble. The resulting photons are detected with a Hamamatsu VUV4 quad-SiPM array - providing the deposited energy with a charge-only RMS resolution of 6.6%. The image reconstruction resolution was estimated to be ~200 um (RMS).



قيم البحث

اقرأ أيضاً

82 - E. Erdal , L. Arazi , A. Tesi 2017
We report on recent advances in the operation of bubble-assisted Liquid Hole Multipliers (LHM). By confining a vapor bubble under or adjacent to a perforated electrode immersed in liquid xenon, we could record both radiation-induced ionization electr ons and primary scintillation photons in the noble liquid. Four types of LHM electrodes were investigated: a THGEM, standard double-conical GEM, 50 $mu$m-thick single-conical GEM (SC-GEM) and 125 $mu$m-thick SC-GEM - all coated with CsI photocathodes. The 125 $mu$m-thick SC-GEM provided the highest electroluminescence (EL) yields, up to ~400 photons per electron over 4$pi$ with an RMS pulse-height resolution reaching 5.5% for events comprising ~7000 primary electrons. Applying a high transfer field across the bubble, the EL yield was further increased by a factor of ~5. The feasibility of a vertical-mode LHM, with the bubble confined between two vertical electrodes, and the operation of a two-stage LHM configuration were demonstrated for the first time. We combine electrostatic simulations with observed signals to draw conclusions regarding the location of the liquid-gas interface and suggest an explanation for the observed differences in EL yield between the investigated electrodes.
69 - E. Erdal , L. Arazi , V. Chepel 2015
Bubble formation in liquid xenon underneath a Thick Gaseous Electron Multiplier (THGEM) electrode immersed in liquid xenon was observed with a CCD camera. With voltage across the THGEM, the appearance of bubbles was correlated with that of electrolum inescence signals induced by ionization electrons from alpha-particle tracks. This confirms recent indirect evidence that the observed photons are due to electroluminescence within a xenon vapor layer trapped under the electrode. The bubbles seem to emerge spontaneously due to heat flow from 300K into the liquid, or in a controlled manner, by locally boiling the liquid with resistive wires. Controlled bubble formation resulted in energy resolution of {sigma}/E~7.5% for ~6,000 ionization electrons. The phenomenon could pave ways towards the conception of large-volume local dual-phase noble-liquid TPCs.
170 - Duval Samuel 2009
The interaction of radiation with liquid xenon, inducing both scintillation and ionization signals, is of particular interest for Compton-sequences reconstruction. We report on the development and recent results of a liquid-xenon time-projection cham ber, dedicated to a novel nuclear imaging technique named 3 gamma imaging. In a first prototype, the scintillation is detected by a vacuum photomultiplier tube and the charges are collected with a MICROMEGAS structure; both are fully immersed in liquid xenon. In view of the final large-area detector, and with the aim of minimizing dead-zones, we are investigating a gaseous photomultiplier for recording the UV scintillation photons. The prototype concept is presented as well as preliminary results in liquid xenon. We also present soft x-rays test results of a gaseous photomultiplier prototype made of a double Thick Gaseous Electron Multiplier (THGEM) at normal temperature and pressure conditions.
90 - A. Tesi , E. Segre , S. Leardini 2021
In bubble-assisted Liquid HoleMultipliers(LHM), developed for noble-liquid radiation detectors, the stability of the bubble and the electro-mechanical properties of the liquid-to-gas interface play a dominant role in the detector performance. A model is proposed to evaluate the static equilibrium configurations of a bubble sustained underneath a perforated electrode immersed in a liquid. For the first time bubbles were optically observed in LAr; their properties were studied in contact with different material surfaces. This permitted investigating the bubble-electrodynamics via numerical simulations; it was shown that the electric field acts as an additional pressure term on the bubble meniscus. The predictions for the liquid-to-gas interface were successfully validated using X-ray micro-CT in water and in silicone oil at STP. The proposed model and the results of this study are an important milestone towards understanding and optimizing the parameters of LHM-based noble-liquid detectors.
A SensL MicroFC-SMT-60035 6x6 mm$^2$ silicon photo-multiplier coated with a NOL-1 wavelength shifter have been tested in the liquid xenon to detect the 175-nm scintillation light. For comparison, a Hamamatsu vacuum ultraviolet sensitive MPPC VUV3 3x3 mm$^2$ was tested under the same conditions. The photodetection efficiency of $13.1 pm 2.5$% and $6.0 pm 1.0$%, correspondingly, is obtained.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا