ترغب بنشر مسار تعليمي؟ اضغط هنا

A virtual coronagraphic test bench for SHARK-NIR, the second-generation high contrast imager for the Large Binocular Telescope

209   0   0.0 ( 0 )
 نشر من قبل Daniele Vassallo
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English
 تأليف D. Vassallo




اسأل ChatGPT حول البحث

In this article, we present a simulator conceived for the conceptual study of an AO-fed high-contrast coronagraphic imager. The simulator implements physical optics: a complex disturbance (the electric field) is Fresnel-propagated through any user-defined optical train, in an end-to-end fashion. The effect of atmospheric residual aberrations and their evolution with time can be reproduced by introducing in input a temporal sequence of phase screens: synthetic images are then generated by co-adding instantaneous PSFs. This allows studying with high accuracy the impact of AO correction on image quality for different integration times and observing conditions. In addition, by conveniently detailing the optical model, the user can easily implement any coronagraphic set-up and introduce optical aberrations at any position. Furthermore, generating multiple images can allow exploring detection limits after a differential post-processing algorithm is applied (e.g. Angular Differential Imaging). The simulator has been developed in the framework of the design of SHARK-NIR, the second-generation high contrast imager selected for the Large Binocular Telescope.



قيم البحث

اقرأ أيضاً

In this paper, we present the infrared coronagraphic test bench of the University of Li`ege named VODCA (Vortex Optical Demonstrator for Coronagraphic Applications). The goal of the bench is to assess the performances of the Annular Groove Phase Mask s (AGPMs) at near- to mid-infrared wavelengths. The AGPM is a subwavelength grating vortex coronagraph of charge two (SGVC2) made out of diamond. The bench is designed to be completely achromatic and will be composed of a super continuum laser source emitting in the near to mid-infrared, several parabolas, diaphragms and an infrared camera. This way, we will be able to test the different AGPMs in the M, L, K and H bands. Eventually, the bench will also allow the computation of the incident wavefront aberrations on the coronagraph. A reflective Lyot stop will send most of the stellar light to a second camera to perform low-order wavefront sensing. This second system coupled with a deformable mirror will allow the correction of the wavefront aberrations. We also aim to test other pre- and/or post-coronagraphic concepts such as optimal apodization.
SHARK-NIR is one of the two coronagraphic instruments proposed for the Large Binocular Telescope. Together with SHARK-VIS (performing coronagraphic imaging in the visible domain), it will offer the possibility to do binocular observations combining d irect imaging, coronagraphic imaging and coronagraphic low resolution spectroscopy in a wide wavelength domain, going from 0.5{mu}m to 1.7{mu}m. Additionally, the contemporary usage of LMIRCam, the coronagraphic LBTI NIR camera, working from K to L band, will extend even more the covered wavelength range. In January 2017 SHARK-NIR underwent a successful final design review, which endorsed the instrument for construction and future implementation at LBT. We report here the final design of the instrument, which foresees two intermediate pupil planes and three focal planes to accomodate a certain number of coronagraphic techniques, selected to maximize the instrument contrast at various distances from the star. Exo-Planets search and characterization has been the science case driving the instrument design, but the SOUL upgrade of the LBT AO will increase the instrument performance in the faint end regime, allowing to do galactic (jets and disks) and extra-galactic (AGN and QSO) science on a relatively wide sample of targets, normally not reachable in other similar facilities.
The mission EXCEDE (EXoplanetary Circumstellar Environments and Disk Explorer), selected by NASA for technology development, is designed to study the formation, evolution and architectures of exoplanetary systems and characterize circumstellar enviro nments into stellar habitable zones. It is composed of a 0.7 m telescope equipped with a Phase-Induced Amplitude Apodization Coronagraph (PIAA-C) and a 2000-element MEMS deformable mirror, capable of raw contrasts of 1e-6 at 1.2 lambda/D and 1e-7 above 2 lambda/D. One of the key challenges to achieve those contrasts is to remove low-order aberrations, using a Low-Order WaveFront Sensor (LOWFS). An experiment simulating the starlight suppression system is currently developed at NASA Ames Research Center, and includes a LOWFS controlling tip/tilt modes in real time at 500 Hz. The LOWFS allowed us to reduce the tip/tilt disturbances to 1e-3 lambda/D rms, enhancing the previous contrast by a decade, to 8e-7 between 1.2 and 2 lambda/D. A Linear Quadratic Gaussian (LQG) controller is currently implemented to improve even more that result by reducing residual vibrations. This testbed shows that a good knowledge of the low-order disturbances is a key asset for high contrast imaging, whether for real-time control or for post processing.
In February 2014, the SHARK-VIS (System for High contrast And coronography from R to K at VISual bands) Forerunner, a high contrast experimental imager operating at visible wavelengths, was installed at LBT (Large Binocular Telescope). Here we report on the first results obtained by recent on-sky tests. These results show the extremely good performance of the LBT ExAO (Extreme Adaptive Optics) system at visible wavelengths, both in terms of spatial resolution and contrast achieved. Similarly to what was done by (Amara et al. 2012), we used the SHARK-VIS Forerunner data to quantitatively assess the contrast enhancement. This is done by injecting several different synthetic faint objects in the acquired data and applying the ADI (angular differential imaging) technique. A contrast of the order of $5 times 10^{-5}$ is obtained at 630 nm for angular separations from the star larger than 100 mas. These results are discussed in light of the future development of SHARK-VIS and compared to those obtained by other high contrast imagers operating at similar wavelengths.
PEPSI is the bench-mounted, two-arm, fibre-fed and stabilized Potsdam Echelle Polarimetric and Spectroscopic Instrument for the 2x8.4 m Large Binocular Telescope (LBT). Three spectral resolutions of either 43 000, 120 000 or 270 000 can cover the ent ire optical/red wavelength range from 383 to 907 nm in three exposures. Two 10.3kx10.3k CCDs with 9-{mu}m pixels and peak quantum efficiencies of 96 % record a total of 92 echelle orders. We introduce a new variant of a wave-guide image slicer with 3, 5, and 7 slices and peak efficiencies between 96 %. A total of six cross dispersers cover the six wavelength settings of the spectrograph, two of them always simultaneously. These are made of a VPH-grating sandwiched by two prisms. The peak efficiency of the system, including the telescope, is 15% at 650 nm, and still 11% and 10% at 390 nm and 900 nm, respectively. In combination with the 110 m2 light-collecting capability of the LBT, we expect a limiting magnitude of 20th mag in V in the low-resolution mode. The R=120 000 mode can also be used with two, dual-beam Stokes IQUV polarimeters. The 270 000-mode is made possible with the 7-slice image slicer and a 100- {mu}m fibre through a projected sky aperture of 0.74, comparable to the median seeing of the LBT site. The 43000-mode with 12-pixel sampling per resolution element is our bad seeing or faint-object mode. Any of the three resolution modes can either be used with sky fibers for simultaneous sky exposures or with light from a stabilized Fabry-Perot etalon for ultra-precise radial velocities. CCD-image processing is performed with the dedicated data-reduction and analysis package PEPSI-S4S. A solar feed makes use of PEPSI during day time and a 500-m feed from the 1.8 m VATT can be used when the LBT is busy otherwise. In this paper, we present the basic instrument design, its realization, and its characteristics.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا