ترغب بنشر مسار تعليمي؟ اضغط هنا

Towards a standard procedure for the measurement of the multi-photon component in a CW telecom heralded single-photon source

167   0   0.0 ( 0 )
 نشر من قبل Fabrizio Piacentini
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Single-photon sources are set to be a fundamental tool for metrological applications as well as for quantum information related technologies. Because of their upcoming widespread dissemination, the need for their characterization and standardization is becoming of the utmost relevance. Here, we illustrate a strategy to provide a quantitative estimate of the multi-photon component of a single-photon source, showing the results achieved in a pilot study for the measurement of the second order autocorrelation function $g^{(2)}$ of a low-noise CW heralded single-photon source prototype (operating at telecom wavelength $lambda=1550$ nm) realized in INRiM. The results of this pilot study, involving PTB, NPL and INRiM, will help to build up a robust and unambiguous procedure for the characterization of the emission of a single-photon source.

قيم البحث

اقرأ أيضاً

Heralded single photon source (HSPS) is an important way in generating genuine single photon, having advantages of experimental simplicity and versatility. However, HSPS intrinsically suffers from the trade-off between the heralded single photon rate and the single photon purity. To overcome this, one can apply multiplexing technology in different degrees of freedom to enhance the performance of HSPS. Here, by employing spectral multiplexing and active feed-forward spectral manipulating, we demonstrate a HSPS at 1.5 {mu}m telecom-band. Our experimental results show that the spectral multiplexing effectively erases the frequency correlation of pair source and significantly improves the heralded single photon rate while keeping the g{^(^2^)}(0) as low as 0.0006{pm}0.0001. The Hong-Ou-Mandel interference between the heralded single photons and photons from an independent weak coherent source indicates a high indistinguishability. Our results pave a way for scalable HSPS by spectral multiplexing towards deterministic single photon emission.
The realization of an ultra-fast source of heralded single photons emitted at the wavelength of 1540 nm is reported. The presented strategy is based on state-of-the-art telecom technology, combined with off-the-shelf fiber components and waveguide no n-linear stages pumped by a 10 GHz repetition rate laser. The single photons are heralded at a rate as high as 2.1 MHz with a heralding efficiency of 42%. Single photon character of the source is inferred by measuring the second-order autocorrelation function. For the highest heralding rate, a value as low as 0.023 is found. This not only proves negligible multi-photon contributions but also represents the best measured value reported to date for heralding rates in the MHz regime. These prime performances, associated with a device-like configuration, are key ingredients for both fast and secure quantum communication protocols.
Blind quantum computation is a scheme that adds unconditional security to cloud quantum computation. In the protocol proposed by Broadbent, Fitzsimons, and Kashefi, the ability to prepare and transmit a single qubit is required for a user (client) wh o uses a quantum computer remotely. In case a weak coherent pulse is used as a pseudo single photon source, however, we must introduce decoy states, owing to the inherent risk of transmitting multiple photon. In this study, we demonstrate that by using a heralded single photon source and a probabilistic photon number resolving detector, we can gain a higher blind state generation efficiency and longer access distance, owing to noise reduction on account of the heralding signal.
We present a heralded single-photon source with a much lower level of unwanted background photons in the output channel by using the herald photon to control a shutter in the heralded channel. The shutter is implemented using a simple field programable gate array controlled optical switch.
We studied intensity fluctuations of a single photon source relying on the pulsed excitation of the fluorescence of a single molecule at room temperature. We directly measured the Mandel parameter Q(T) over 4 orders of magnitude of observation timesc ale T, by recording every photocount. On timescale of a few excitation periods, subpoissonian statistics is clearly observed and the probablility of two-photons events is 10 times smaller than Poissonian pulses. On longer times, blinking in the fluorescence, due to the molecular triplet state, produces an excess of noise.