Anode current saturation of ALD-coated Planacon MCP-PMTs

73   0   0.0 ( 0 )
 نشر من قبل Yury Melikyan Mr
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We have measured and compared the characteristics of ALD-coated Planacon MCP-PMTs (XP85112/A1-Q-L) with their non-ALD counterparts (XP85012/A1-Q). While the later show excellent performance, the ALD-coated sensors have surprisingly low current saturation levels (~two orders of magnitude lower than expected) and extremely high gain recovery time (more than 7 orders of magnitude higher than expected). We suspect that these problems might be caused by the unexpected side-effects of the ALD process. To make a definite conclusion, more samples need to be tested, preferably from different production runs. If our observation were confirmed, it would mean a serious technological setback for ALD-coated MCP-PMTs.



قيم البحث

اقرأ أيضاً

The motivation of this paper is to explore the parameters that affect the performance of Microchannel Plate Photomultiplier Tubes (MCP-PMTs) in magnetic fields with the goal to guide their design to achieve a high magnetic field tolerance. MCP-PMTs b ased on two different designs were tested.The magnetic field tolerance of MCP-PMT based on a design providing independently biased voltages showed a significant improvement (up to 0.7 T) compared to the one utilizing an internal resistor chain design (up to 0.1 T), indicating the importance of individually adjustable voltages. The effects of the rotation angle of the MCP-PMT relative to the magnetic field direction and of the bias voltage between the photocathode and the top MCP were extensively investigated using the MCP-PMT based on the independently biased voltage design. It was found that the signal amplitude of the MCP-PMT exhibits an enhanced performance at a tilt angle of $pm$8$^{circ}$, due to the 8$^{circ}$ bias angle of the MCP pores. The maximum signal amplitude was observed at different bias voltages depending on the magnetic field strength.
177 - K.Inami , T.Mori , T.Matsumura 2008
We have developed a 4-channel multi-anode MCP-PMT, SL10, which exhibits a performance of sigma_TTS ~ 30 ps for single photons with G ~ 10^6 and QE=20% under a magnetic field of B <= 1.5 T. The cross-talk among anodes has been extensively studied. We have taken two measures to suppress it: one is to configure the SL10 to an effectively independent 4 small pieces of MCP-PMTs by segmenting an electrode of the second MCP-layer; the other is to use a constant fractional discriminator. Remarkable improvement has been achieved.
JUNO is a 20-kton liquid scintillator detector aiming to determine the neutrino mass ordering, precisely measure the oscillation parameters, detect the astrophysical neutrinos and search for exotic physics. It is designed to reach an energy resolutio n of 3% at 1 MeV with the highest ever PMT coverage, using two types of 20 inch phototubes: MCP-PMT from NNVT and dynode-PMT from Hamamatsu. In this article, the gain and charge response of the MCP and dynode PMTs are investigated with the study of JUNO Central Detector prototype. The linearity of the MCP-PMT charge output is measured too to check the effect of a long tail on its charge spectrum.
59 - T. Matsumoto 2003
A proximity focusing ring imaging Cherenkov detector using aerogel as the radiator has been studied for an upgrade of the Belle detector at the KEK-B-factory. We constructed a prototype Cherenkov counter using a 4 x 4 array of 64-channel flat-panel m ulti-anode PMTs (Hamamatsu H8500) with a large effective area. The aerogel samples were made with a new technique to obtain a higher transmission length at a high refractive index (n=1.05). Multi-channel PMTs are read-out with analog memory chips. The detector was tested at the KEK-PS pi2 beam line in November, 2002. To evaluate systematically the performance of the detector, tests were carried out with various aerogel samples using pion beams with momenta between 0.5 GeV/c and 4 GeV/c. The typical angular resolution was around 14 mrad, and the average number of detected photoelectrons was around 6. We expect that pions and kaons can be separated at a 4 sigma level at 4 GeV/c.
251 - T.Jinno , T.Mori , T.Ohshima 2010
In order to develop a long-lifetime MCP-PMT under high rates of circumstance, we investigated the degradation of the quantum efficiency (QE) of PMTs with a multialkali photocathode. We found that not only positive ions, but also neutral residual gase s would damage the photocathode resulting in an enhancement of the work function; their countermeasures were established in newly manufactured square-shaped MCP-PMTs with 4 or 4x4 multi-anodes. The performances of the PMTs were measured: QE was stable up to an integrated amount of anode output charge of 2-3 C/cm^2, while keeping other basic performances steady, such as the time resolution for single photons of ~40 ps, a photoelectron collection efficiency (CE) of 60%, a multiplication gain (G) of a few x 10^6, and dark counts of 20-300 Hz. The causes of QE degradation are discussed.