ترغب بنشر مسار تعليمي؟ اضغط هنا

Design of a CubeSat Payload to Test a Magnetic Measurement System for Space-borne Gravitational Wave Detectors

115   0   0.0 ( 0 )
 نشر من قبل Ignacio Mateos
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Space observatories for gravitational radiation such as LISA are equipped with dedicated on-board instrumentation capable of measuring magnetic fields with low-noise conditions at millihertz frequencies. The reason is that the core scientific payload can only operate successfully if the magnetic environment meets certain strict low-frequency requirements. With this purpose, a simplified version of the proposed magnetic measurement system for LISA has been developed for a six-unit CubeSat, which will make it possible to improve the technology readiness level (TRL) of the instrument. The special feature of the experiment is that the magnetic sensors integrated in the payload are magnetically shielded to low-frequency fluctuations by using a small cylindrical permalloy enclosure. This will allow the in-flight noise characterization of the system under the CubeSat orbit environment. Therefore, a CubeSat platform will offer the opportunity to measure the capability of the instrument and will guide the progress towards the improved magnetic measurement system for LISA. This article describes the principal characteristics and implementation of the CubeSat payload.


قيم البحث

اقرأ أيضاً

Future space borne gravitational wave detectors will require a precise definition of calibration signals to ensure the achievement of their design sensitivity. The careful design of the test signals plays a key role in the correct understanding and c haracterisation of these instruments. In that sense, methods achieving optimal experiment designs must be considered as complementary to the parameter estimation methods being used to determine the parameters describing the system. The relevance of experiment design is particularly significant for the LISA Pathfinder mission, which will spend most of its operation time performing experiments to characterise key technologies for future space borne gravitational wave observatories. Here we propose a framework to derive the optimal signals ---in terms of minimum parameter uncertainty--- to be injected to these instruments during its calibration phase. We compare our results with an alternative numerical algorithm which achieves an optimal input signal by iteratively improving an initial guess. We show agreement of both approaches when applied to the LISA Pathfinder case.
A Drag-Free CubeSat mission has been proposed to demonstrate the feasibility of a Gravitational Reference Sensor (GRS) with an optical readout for a 3 units (3U) spacecraft. A purely drag-free object is defined by the absence of all external forces o ther than gravity, which are shielded by the spacecraft. In a real case, the TM will still be affected by disturbances. Several of them are passively reduced by the design of the TM housing. This system is a thick-walled aluminium box that holds the shadow sensors and shields the TM. The housing has an effect on the mechanical, thermal and magnetic environment around the TM. All of them have been analysed. The mechanical vibrations have to fit the launch environment and the modes have to be outside of the measurement range (0.0001 - 1 Hz). The magnetic field has to be reduced by a 0.01 factor. The temperature difference between internal opposing surfaces, determining pressure on the TM, has to be below 10^-3(1 mHz/f)1/3 K Hz^-1/2. The housing, together with the TM, the sensors and the UV LEDs for charging control, constitutes the GRS, which would then fit into a 1U. The other 2Us are occupied by the caging mechanism that constraints the TM during launch, the thrusters, the Attitude Determination And Control System (ADACS) and the electronics. The Drag-Free CubeSat will be the result of the combined efforts of Stanford, University of Florida, KACST and NASA and will be the first drag-free mission with an optical readout and the first GRS designed within the limits of a 3U small satellite. In the first section, this paper briefly updates on the main characteristics and systems of the project. Particular emphasis is then given to the recently designed housing, its expected performance and the open issues.
IDeF-X HD is a 32-channel analog front-end with self-triggering capability optimized for the readout of 16 x 16 pixels CdTe or CdZnTe pixelated detectors to build low power micro gamma camera. IDeF-X HD has been designed in the standard AMS CMOS 0.35 microns process technology. Its power consumption is 800 micro watt per channel. The dynamic range of the ASIC can be extended to 1.1 MeV thanks to the in-channel adjustable gain stage. When no detector is connected to the chip and without input current, a 33 electrons rms ENC level is achieved after shaping with 10.7 micro seconds peak time. Spectroscopy measurements have been performed with CdTe Schottky detectors. We measured an energy resolution of 4.2 keV FWHM at 667 keV (137-Cs) on a mono-pixel configuration. Meanwhile, we also measured 562 eV and 666 eV FWHM at 14 keV and 60 keV respectively (241-Am) with a 256 small pixel array and a low detection threshold of 1.2 keV. Since IDeF-X HD is intended for space-borne applications in astrophysics, we evaluated its radiation tolerance and its sensitivity to single event effects. We demonstrated that the ASIC remained fully functional without significant degradation of its performances after 200 krad and that no single event latch-up was detected putting the Linear Energy Transfer threshold above 110 MeV/(mg/cm2). Good noise performance and radiation tolerance make the chip well suited for X-rays energy discrimination and high-energy resolution. The chip is space qualified and flies on board the Solar Orbiter ESA mission launched in 2020.
This paper reviews some of the key enabling technologies for advanced and future laser interferometer gravitational wave detectors, which must combine test masses with the lowest possible optical and acoustic losses, with high stability lasers and va rious techniques for suppressing noise. Sect. 1 of this paper presents a review of the acoustic properties of test masses. Sect. 2 reviews the technology of the amorphous dielectric coatings which are currently universally used for the mirrors in advanced laser interferometers, but for which lower acoustic loss would be very advantageous. In sect. 3 a new generation of crystalline optical coatings that offer a substantial reduction in thermal noise is reviewed. The optical properties of test masses are reviewed in sect. 4, with special focus on the properties of silicon, an important candidate material for future detectors. Sect. 5 of this paper presents the very low noise, high stability laser technology that underpins all advanced and next generation laser interferometers.
135 - Xiao-Yu Lu , Yu-Jie Tan , 2020
Time-delay interferometry is put forward to improve the signal-to-noise ratio of space-borne gravitational wave detectors by canceling the large laser phase noise with different combinations of measured data. Based on the Michelson data combination, the sensitivity function of the detector can be obtained by averaging the all-sky wave source positions. At present, there are two main methods to encode gravitational wave signal into detector. One is to adapt gravitational wave polarization angle depending on the arm orientation in the gravitational wave frame, and the other is to divide the gravitational wave signal into plus and cross polarizations in the detector frame. Although there are some attempts using the first method to provide the analytical expression of sensitivity function, only a semianalytical one could be obtained. Here, starting with the second method, we demonstrate the equivalence of both methods. First time to obtain the full analytical expression of sensitivity function, which provides a fast and accurate mean to evaluate and compare the performance of different space-borne detectors, such as LISA and TianQin.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا