ترغب بنشر مسار تعليمي؟ اضغط هنا

Measurement of the time-integrated $CP$ asymmetry in $D^0 rightarrow K^0_S K^0_S$ decays

88   0   0.0 ( 0 )
 نشر من قبل Giulia Tuci
 تاريخ النشر 2018
  مجال البحث
والبحث باللغة English




اسأل ChatGPT حول البحث

A measurement of the time-integrated $CP$ asymmetry in $D^0rightarrow K^0_S K^0_S$ decays is reported. The data correspond to an integrated luminosity of about $2$ fb$^{-1}$ collected in 2015-2016 by the LHCb collaboration in $pp$ collisions at a centre-of-mass energy of $13$ TeV. The $D^0$ candidate is required to originate from a $D^{ast +} rightarrow D^0 pi^+$ decay, allowing the determination of the flavour of the $D^0$ meson using the pion charge. The $D^0 rightarrow K^{+}K^{-}$ decay, which has a well measured $CP$ asymmetry, is used as a calibration channel. The $CP$ asymmetry for $D^0rightarrow K^0_S K^0_S$ is measured to be begin{equation*} mathcal{A}^{CP}(D^0rightarrow K^0_S K^0_S) = (4.3pm 3.4pm 1.0)%, end{equation*} where the first uncertainty is statistical and the second is systematic. This result is combined with the previous LHCb measurement at lower centre-of-mass energies to obtain begin{equation*} mathcal{A}^{CP}(D^0rightarrow K^0_S K^0_S) = (2.3pm 2.8pm 0.9)%. end{equation*}

قيم البحث

اقرأ أيضاً

The time-integrated $CP$ asymmetry in the decay $D^0 to K^0_S K^0_S$ is measured using $3 fb^{-1}$ of proton-proton collision data collected by the LHCb experiment at centre-of-mass energies of 7 and 8 TeV. The flavour of the $D^0$ meson is determine d by use of the decay $D^{*+} to D^0 pi^+$ and its charge conjugate mode. The result is [ {cal A}_{CP} = -0.029 pm 0.052 pm 0.022, ] where the first uncertainty is statistical and the second systematic. The result is consistent with Standard Model expectations and improves the uncertainty with respect to the only previous measurement of this quantity by more than a factor of three.
We report a measurement of the time-integrated $CP$ asymmetry in the neutral charm meson decay $D^0 to K^0_S K^0_S$ using 921~fb$^{-1}$ data collected at the $Upsilon(4S)$ and $Upsilon(5S)$ resonances with the Belle detector at the KEKB asymmetric-en ergy $e^+e^-$ collider. The observed asymmetry is $$ A_{CP}(D^0 to K^0_S K^0_S) = (-0.02 pm 1.53 pm 0.17) %, $$ where the first uncertainty is statistical and the second systematic. This latter uncertainty is dominated by the error of the normalisation channel. The result is consistent with Standard Model expectations and improves the uncertainty with respect to previous measurement of this quantity by more than a factor of three.
We report on measurements of the time-dependent CP violating observables in $B^0_srightarrow D^{mp}_s K^{pm}$ decays using a dataset corresponding to 1.0 fb$^{-1}$ of pp collisions recorded with the LHCb detector. We find the CP violating observables $C_f=0.53pm0.25pm0.04$, $A^{DeltaGamma}_f=0.37pm0.42pm0.20$, $A^{DeltaGamma}_{bar{f}}=0.20pm0.41pm0.20$, $S_f=-1.09pm0.33pm0.08$, $S_{bar{f}}=-0.36pm0.34pm0.08$, where the uncertainties are statistical and systematic, respectively. Using these observables together with a recent measurement of the $B^0_s$ mixing phase $-2beta_s$ leads to the first extraction of the CKM angle $gamma$ from $B^0_s rightarrow D^{mp}_s K^{pm}$ decays, finding $gamma$ = (115$_{-43}^{+28}$)$^circ$ modulo 180$^circ$ at 68% CL, where the error contains both statistical and systematic uncertainties.
Measurements are presented of the $CP$ violation observables $S$ and $C$ in the decays of $B^0$ and $overline{B}{}^0$ mesons to the $J/psi K^0_S$ final state. The data sample corresponds to an integrated luminosity of $3.0,text{fb}^{-1}$ collected wi th the LHCb experiment in proton-proton collisions at center-of-mass energies of $7$ and $8,text{TeV}$. The analysis of the time evolution of $41500$ $B^0$ and $overline{B}{}^0$ decays yields $S = 0.731 pm 0.035 , text{(stat)} pm 0.020 ,text{(syst)}$ and $C = -0.038 pm 0.032 , text{(stat)} pm 0.005,text{(syst)}$. In the Standard Model, $S$ equals $sin(2beta)$ to a good level of precision. The values are consistent with the current world averages and with the Standard Model expectations.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا