ترغب بنشر مسار تعليمي؟ اضغط هنا

Characterization of Hamamatsu 64-channel TSV SiPMs

45   0   0.0 ( 0 )
 نشر من قبل Max Renschler
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The Hamamatsu UV-light enhanced 64-channel SiPM array of the newest generation (S13361-3050AS-08) has been examined for the purpose of being used for the Silicon Elementary Cell Add-on (SiECA) of the EUSO-SPB balloon experiment. Characterization measurements have been performed with the newly installed Single Photon Calibration Stand at KIT (SPOCK). The results of the characterization measurements including the breakdown voltage, the gain, the PDE, the dark-count rate and the crosstalk probability of all 64 SiPM channels are presented. Additional measurements of the SiPM sensitivity to photons with wavelengths lower than 400nm show an improved PDE for small wavelengths compared to the SiPM array S12642-0808PA-50, which was also investigated for comparison. The response dynamics have been investigated for low numbers of incoming photons. Temperature dependent measurements of the gain, the PDE, the dark-count rate and the crosstalk probability have been performed for one channel of the SiPM array.


قيم البحث

اقرأ أيضاً

In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation li ght for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 text{ } text{K} leq text{T}leq 233 text{ } text{K}$. At an over voltage of $3.1pm0.2$ V and at $text{T}=163 text{ }text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 upmutext{s}$ interval following the trigger pulse of $0.161pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137pm0.002 text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $text{T}=233 text{ }text{K}$ for a mean wavelength of $189pm7text{ nm}$. At $3.6pm0.2$ V and $3.5pm0.2$ V of over voltage we report a PDE of $13.4pm2.6text{ }%$ and $11pm2%$, corresponding to a saturation PDE of $14.8pm2.8text{ }%$ and $12.2pm2.3%$, respectively. Both values are well below the $24text{ }%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
36 - F. Rehbein , T. Bretz , R. Alfaro 2020
The optical coupling of light guides to Silicon Photomultipliers (SiPMs) influences the probability for optical crosstalk. Measurements of the crosstalk probability and the relative gain of 122 SiPMs of type SensL MicroFJ-60035-TSV are presented. Sem i-conductor photo sensors have replaced photo multiplier tubes in numerous applications featuring single-photon resolution, insensitivity to magnetic fields, higher robustness and enhanced photo detection efficiency at lower operation voltage and lower costs. Light guides are used to increase the comparably small photo sensitive area of SiPMs. Their optical coupling changes the surface conditions of the sensor and influences the probability for crosstalk photons to leave the sensor without inducing secondary breakdowns. This study compares properties of sensors that are optically coupled to light guides with bare sensors, operated at nominal bias voltage. It demonstrates, that the optical coupling to a light guide significantly reduces the crosstalk probability of the measured sensors.
The Hamamatsu R11410 photomultiplier, a tube of 3 diameter and with a very low intrinsic radioactivity, is an interesting light sensor candidate for future experiments using liquid xenon (LXe) as target for direct dark matter searches. We have perfor med several experiments with the R11410 with the goal of testing its performance in environments similar to a dark matter detector setup. In particular, we examined its long-term behavior and stability in LXe and its response in various electric field configurations.
The third-generation South Pole Telescope camera is designed to measure the cosmic microwave background across three frequency bands (95, 150 and 220 GHz) with ~16,000 transition-edge sensor (TES) bolometers. Each multichroic pixel on a detector wafe r has a broadband sinuous antenna that couples power to six TESs, one for each of the three observing bands and both polarization directions, via lumped element filters. Ten detector wafers populate the focal plane, which is coupled to the sky via a large-aperture optical system. Here we present the frequency band characterization with Fourier transform spectroscopy, measurements of optical time constants, beam properties, and optical and polarization efficiencies of the focal plane. The detectors have frequency bands consistent with our simulations, and have high average optical efficiency which is 86%, 77% and 66% for the 95, 150 and 220 GHz detectors. The time constants of the detectors are mostly between 0.5 ms and 5 ms. The beam is round with the correct size, and the polarization efficiency is more than 90% for most of the bolometers
In this work we present an active Compton scattering polarimeter as a focal plane instrument able to extend the X-ray polarimetry towards hard X-rays. Other authors have already studied various instrument design by means of Monte Carlo simulations, i n this work we will show for the first time the experimental measurements of tagging efficiency aimed to evaluate the polarimeter sensitivity as a function of energy. We performed a characterization of different scattering materials by measuring the tagging efficiency that was used as an input to the Monte Carlo simulation. Then we calculated the sensitivity to polarization of a design based on the laboratory set-up. Despite the geometry tested is not optimized for a realistic focal plane instrument, we demonstrated the feasibility of polarimetry with a low energy threshold of 20 keV. Moreover we evaluated a Minimum Detectable Polarization of 10% for a 10 mCrab source in 100 ks between 20 and 80 keV in the focal plane of one multilayer optics module of NuSTAR. The configuration used consisted of a doped p-terphenyl scatterer 3 cm long and 0.7 cm of diameter coupled with a 0.2 cm thick LaBr3 absorber.
التعليقات