ترغب بنشر مسار تعليمي؟ اضغط هنا

Characterization of Pulsar Sources for X-ray Navigation

63   0   0.0 ( 0 )
 نشر من قبل Paul S. Ray
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The Station Explorer for X-ray Timing and Navigation Technology (SEXTANT) is a technology demonstration enhancement to the Neutron Star Interior Composition Explorer (NICER) mission, which is scheduled to launch in 2017 and will be hosted as an externally attached payload on the International Space Station (ISS). During NICERs 18-month baseline science mission to understand ultra-dense matter through observations of neutron stars in the soft X-ray band, SEXTANT will, for the first-time, demonstrate real-time, on-board X-ray pulsar navigation. Using NICER/SEXTANT as an example, we describe the factors that determine the measurement errors on pulse times of arrival, including source and background count rates, and pulse profile shapes. We then describe properties of the SEXTANT navigation pulsar catalog and prospects for growing it once NICER launches. Finally, we describe the factors affecting the prediction of pulse arrival times in advance, including variable interstellar propagation effect and red timing noise. Together, all of these factors determine how well a particular realization of an X-ray pulsar-based navigation system will perform.

قيم البحث

اقرأ أيضاً

In this work, we report the in-orbit demonstration of X-ray pulsar navigation with Insight-Hard X-ray Modulation Telescope (Insight-HXMT), which was launched on Jun. 15th, 2017. The new pulsar navigation method Significance Enhancement of Pulse-profi le with Orbit-dynamics (SEPO) is adopted to determine the orbit with observations of only one pulsar. In this test, the Crab pulsar is chosen and observed by Insight-HXMT from Aug. 31th to Sept. 5th in 2017. Using the 5-day-long observation data, the orbit of Insight-HXMT is determined successfully with the three telescopes onboard - High Energy X-ray Telescope (HE), Medium Energy X-ray Telescope (ME) and Low Energy X-ray Telescope (LE) - respectively. Combining all the data, the position and velocity of the Insight-HXMT are pinpointed to within 10 km (3 sigma) and 10 m/s (3 sigma), respectively.
X-ray Charge Coupled Devices (CCDs) have been the workhorse for soft X-ray astronomical instruments for the past quarter century. They provide broad energy response, extremely low electronic read noise, and good energy resolution in soft X-rays. Thes e properties, along with the large arrays and small pixel sizes available with modern-day CCDs, make them a potential candidate for next generation astronomical X-ray missions equipped with large collecting areas, high angular resolutions and wide fields of view, enabling observation of the faint, diffuse and high redshift X-ray universe. However, such high collecting area (about 30 times Chandra) requires these detectors to have an order of magnitude faster readout than current CCDs to avoid saturation and pile up effects. In this context, Stanford University and MIT have initiated the development of fast readout X-ray cameras. As a tool for this development, we have designed a fast readout, low noise electronics board (intended to work at a 5 Megapixel per second data rate) coupled with an STA Archon controller to readout a 512 x 512 CCD (from MIT Lincoln Laboratory). This versatile setup allows us to study a number of parameters and operation conditions including the option for digital shaping. In this paper, we describe the characterization test stand, the concept and development of the readout electronics, and simulation results. We also report the first measurements of read noise, energy resolution and other parameters from this set up. While this is very much a prototype, we plan to use larger, multi-node CCD devices in the future with dedicated ASIC readout systems to enable faster, parallel readout of the CCDs.
147 - E.Chiosi , M.Orio , F. Bernardini 2014
We searched optical/UV/IR counterparts of seven supersoft X-ray sources (SSS) in M31 in the Hubble Space Telescope (HST) Panchromatic Hubble Andromeda Treasury (PHAT) archival images and photometric catalog. Three of the SSS were transient, the other four are persistent sources. The PHAT offers the opportunity to identify SSS hosting very massive white dwarfs that may explode as type Ia supernovae in single degenerate binaries, with magnitudes and color indexes typical of symbiotic stars, high mass close binaries, or systems with optically luminous accretion disks. We find evidence that the transient SSS were classical or recurrent novae; two likely counterparts we identified are probably symbiotic binaries undergoing mass transfer at a very high rate. There is a candidate accreting white dwarf binary in the error circle of one of the persistent sources, r3-8. In the spatial error circle of the best studied SSS in M31, r2-12, no red giants or AGB stars are sufficiently luminous in the optical and UV bands to be symbiotic systems hosting an accreting and hydrogen burning white dwarf. This SSS has a known modulation of the X-ray flux with a 217.7 s period, and we measured an upper limit on its derivative, 0.82 x 10(-11). This limit can be reconciled with the rotation period of a white dwarf accreting at high rate in a binary with a few-hours orbital period. However, there is no luminous counterpart with color indexes typical of an accretion disk irradiated by a hot central source. Adopting a semi-empirical relationship, the upper limit for the disk optical luminosity implies an upper limit of only 169 minutes for the orbital period of the white dwarf binary.
X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. T his compounds the data acquisition time necessary to statistically sample the instrumental line broadening, and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals which are aligned in a dispersive configuration to select the kaone line of the x-ray tube anode material. The entire device, including x-ray tube, can be easily hand carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100-200 $mu$m for the x-ray tubes used here), and is unfocused in the cross-dispersion direction, so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi Soft X-ray Spectrometer, which had 819 $mu$m square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs) which have effective theoretical FWHM energy resolution of 0.125, 0.197, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our crkaone monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.
In-spiraling supermassive black holes should emit gravitational waves, which would produce characteristic distortions in the time of arrival residuals from millisecond pulsars. Multiple national and regional consortia have constructed pulsar timing a rrays by precise timing of different sets of millisecond pulsars. An essential aspect of precision timing is the transfer of the times of arrival to a (quasi-)inertial frame, conventionally the solar system barycenter. The barycenter is determined from the knowledge of the planetary masses and orbits, which has been refined over the past 50 years by multiple spacecraft. Within the North American Nanohertz Observatory for Gravitational Waves (NANOGrav), uncertainties on the solar system barycenter are emerging as an important element of the NANOGrav noise budget. We describe what is known about the solar system barycenter, touch upon how uncertainties in it affect gravitational wave studies with pulsar timing arrays, and consider future trends in spacecraft navigation.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا