ترغب بنشر مسار تعليمي؟ اضغط هنا

Analysing Magnetism Using Scanning SQUID Microscopy

71   0   0.0 ( 0 )
 نشر من قبل Pim Reith
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Scanning superconducting quantum interference device microscopy (SSM) is a scanning probe technique that images local magnetic flux, which allows for mapping of magnetic fields with high field and spatial accuracy. Many studies involving SSM have been published in the last decades, using SSM to make qualitative statements about magnetism. However, quantitative analysis using SSM has received less attention. In this work, we discuss several aspects of interpreting SSM images and methods to improve quantitative analysis. First, we analyse the spatial resolution and how it depends on several factors. Second, we discuss the analysis of SSM scans and the information obtained from the SSM data. Using simulations, we show how signals evolve as a function of changing scan height, SQUID loop size, magnetization strength and orientation. We also investigated 2-dimensional autocorrelation analysis to extract information about the size, shape and symmetry of magnetic features. Finally, we provide an outlook on possible future applications and improvements.

قيم البحث

اقرأ أيضاً

104 - Manuela Gerken 2019
Fabrication, characterization and comparison of gold and graphene micro- and nano-size Hall sensors for room temperature scanning magnetic field microscopy applications is presented. The Hall sensors with active areas from 5 $mu$m down to 50 nm were fabricated by electron-beam lithography. The calibration of the Hall sensors in an external magnetic field revealed a sensitivity of 3.2 mV/(AT) $pm$ 0.3 % for gold and 1615 V/(AT) $pm$ 0.5 % for graphene at room temperature. The gold sensors were fabricated on silicon nitride cantilever chips suitable for integration into commercial scanning probe microscopes, allowing scanning Hall microscopy (SHM) under ambient conditions and controlled sensor-sample distance. The height dependent stray field distribution of a magnetic scale was characterized using a 5 $mu$m gold Hall sensor. The uncertainty of the entire Hall sensor based scanning and data acquisition process was analyzed allowing traceably calibrated SHM measurements. The measurement results show good agreement with numerical simulations within the uncertainty budget.
We describe a hybrid pixel array detector (EMPAD - electron microscope pixel array detector) adapted for use in electron microscope applications, especially as a universal detector for scanning transmission electron microscopy. The 128 x 128 pixel de tector consists of a 500 um thick silicon diode array bump-bonded pixel-by-pixel to an application-specific integrated circuit (ASIC). The in-pixel circuitry provides a 1,000,000:1 dynamic range within a single frame, allowing the direct electron beam to be imaged while still maintaining single electron sensitivity. A 1.1 kHz framing rate enables rapid data collection and minimizes sample drift distortions while scanning. By capturing the entire unsaturated diffraction pattern in scanning mode, one can simultaneously capture bright field, dark field, and phase contrast information, as well as being able to analyze the full scattering distribution, allowing true center of mass imaging. The scattering is recorded on an absolute scale, so that information such as local sample thickness can be directly determined. This paper describes the detector architecture, data acquisition (DAQ) system, and preliminary results from experiments with 80 to 200 keV electron beams.
A transimpedance amplifier has been designed for scanning tunneling microscopy (STM). The amplifier features low noise (limited by the Johnson noise of the 1 G{Omega} feedback resistor at low input current and low frequencies), sufficient bandwidth f or most STM applications (50 kHz at 35 pF input capacitance), a large dynamic range (0.1 pA--50 nA without range switching), and a low input voltage offset. The amplifier is also suited for placing its first stage into the cryostat of a low-temperature STM, minimizing the input capacitance and reducing the Johnson noise of the feedback resistor. The amplifier may also find applications for specimen current imaging and electron-beam-induced current measurements in scanning electron microscopy and as a photodiode amplifier with a large dynamic range. This paper also discusses the sources of noise including the often neglected effect of non-balanced input impedance of operational amplifiers and describes how to accurately measure and adjust the frequency response of low-current transimpedance amplifiers.
145 - Y. P. Pan , J. J. Zhu , Y. Feng 2021
Scanning superconducting quantum interference device microscopy (sSQUID) is currently one of the most effective methods for direct and sensitive magnetic flux imaging on the mesoscopic scale. A SQUID-on-chip design allows integration of field coils f or susceptometry in a gradiometer setup which is very desirable for measuring magnetic responses of quantum matter. However, the spatial resolution of such a design has largely been limited to micrometers due to the difficulty in approaching the sample. Here, we used electron beam lithography technology in the fabrication of the 3D nano-bridge-based SQUID devices to prepare pick-up coils with diameters down to 150 nm. Furthermore, we integrated the deep silicon etching process in order to minimize the distance between the pick-up coil and the wafer edge. Combined with a tuning-fork-based scanning head, the sharpness of the etched chip edge enables a precision of 5 nm in height control. By scanning measurements on niobium chessboard samples using these improved SQUID devices, we demonstrate sub-micron spatial resolutions in both magnetometry and susceptometry, significantly better than our previous generations of nano-SQUIDs. Such improvement in spatial resolution of SQUID-on-chip is a valuable progress for magnetic imaging of quantum materials and devices in various modes.
Recent progress in phase modulation using nanofabricated electron holograms has demonstrated how the phase of an electron beam can be controlled. In this paper, we apply this concept to the correction of spherical aberration in a scanning transmissio n electron microscope and demonstrate an improvement in spatial resolution. Such a holographic approach to spherical aberration correction is advantageous for its simplicity and cost-effectiveness.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا