ترغب بنشر مسار تعليمي؟ اضغط هنا

The MEGII detector

112   0   0.0 ( 0 )
 نشر من قبل Paolo Walter Cattaneo
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English
 تأليف P.W. Cattaneo




اسأل ChatGPT حول البحث

We present a report of the MEG II experiment, the upgrade of MEG, whose goal is to search for the forbidden decay megc with increased precision. After having briefly reviewed the motivation for such a search and the current limit due to MEG, we present the conceptual design of the detector detailing for each subdetector the motivations and the extent of the upgrade and the expected resolution improvements. Novel subdetectors and calibration hardware are introduced. We conclude with the expected sensitivity of the MEGII experiment.

قيم البحث

اقرأ أيضاً

For the final running period of HERA, a recoil detector was installed at the HERMES experiment to improve measurements of hard exclusive processes in charged-lepton nucleon scattering. Here, deeply virtual Compton scattering is of particular interest as this process provides constraints on generalised parton distributions that give access to the total angular momenta of quarks within the nucleon. The HERMES recoil detector was designed to improve the selection of exclusive events by a direct measurement of the four-momentum of the recoiling particle. It consisted of three components: two layers of double-sided silicon strip sensors inside the HERA beam vacuum, a two-barrel scintillating fibre tracker, and a photon detector. All sub-detectors were located inside a solenoidal magnetic field with an integrated field strength of 1 T. The recoil detector was installed in late 2005. After the commissioning of all components was finished in September 2006, it operated stably until the end of data taking at HERA end of June 2007. The present paper gives a brief overview of the physics processes of interest and the general detector design. The recoil detector components, their calibration, the momentum reconstruction of charged particles, and the event selection are described in detail. The paper closes with a summary of the performance of the detection system.
The JSNS^2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV^2 mass-splitting range. The experiment will search for the appearance of electron antine utrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS^2 detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this paper, we describe the JSNS^2 detector design, construction, and operation.
97 - M. Artuso , R. Ayad , K. Bukin 2005
We describe the design, construction and performance of a Ring Imaging Cherenkov Detector (RICH) constructed to identify charged particles in the CLEO experiment. Cherenkov radiation occurs in LiF crystals, both planar and ones with a novel ``sawtoot h-shaped exit surface. Photons in the wavelength interval 135--165 nm are detected using multi-wire chambers filled with a mixture of methane gas and triethylamine vapor. Excellent pion/kaon separation is demonstrated.
EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection cham ber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most innovative aspects of the design that revolve around the reduction of backgrounds, the efficient use of the expensive isotopically enriched xenon, and the optimization of the energy resolution in a relatively large volume.
The large-volume liquid-scintillator detector LENA (Low Energy Neutrino Astronomy) has been proposed as a next-generation experiment for low-energy neutrinos. High-precision spectroscopy of solar, Supernova and geo-neutrinos provides a new access to the otherwise unobservable interiors of Earth, Sun and heavy stars. Due to the potent background discrimination, the detection of the Diffuse Supernova Neutrino Background is expected for the first time in LENA. The sensitivity of the proton lifetime for the decay into Kaon and antineutrino will be increased by an order of magnitude over existing experimental limits. Recent studies indicate that liquid-scintillator detectors are capable to reconstruct neutrino events even at GeV energies, providing the opportunity to use LENA as far detector in a long-baseline neutrino beam experiment.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا