ترغب بنشر مسار تعليمي؟ اضغط هنا

Development of $^{100}$Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search

75   0   0.0 ( 0 )
 نشر من قبل Denys Poda
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ($sim$1~kg), high optical quality, radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been produced and used to develop high performance single detector modules based on 0.2--0.4~kg scintillating bolometers. In particular, the energy resolution of the lithium molybdate detectors near the $Q$-value of the double-beta transition of $^{100}$Mo (3034~keV) is 4--6~keV FWHM. The rejection of the $alpha$-induced dominant background above 2.6~MeV is better than 8$sigma$. Less than 10~$mu$Bq/kg activity of $^{232}$Th ($^{228}$Th) and $^{226}$Ra in the crystals is ensured by boule recrystallization. The potential of $^{100}$Mo-enriched scintillating bolometers to perform high sensitivity double-beta decay searches has been demonstrated with only 10~kg$times$d exposure: the two neutrino double-beta decay half-life of $^{100}$Mo has been measured with the up-to-date highest accuracy as $T_{1/2}$ = [6.90 $pm$ 0.15(stat.) $pm$ 0.37(syst.)] $times$ 10$^{18}$~yr. Both crystallization and detector technologies favor lithium molybdate, which has been selected for the ongoing construction of the CUPID-0/Mo demonstrator, containing several kg of $^{100}$Mo.

قيم البحث

اقرأ أيضاً

NEXT-100 is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta ($beta beta 0 u$) decay of Xe-136. The detector possesses two features of great value for $beta beta 0 u$ searches: energy resolution better than 1% FWHM at the $Q$ value of Xe-136 and track reconstruction for the discrimination of signal and background events. This combination results in excellent sensitivity, as discussed in this paper. Material-screening measurements and a detailed Monte Carlo detector simulation predict a background rate for NEXT-100 of at most $4times10^{-4}$ counts keV$^{-1}$ kg$^{-1}$ yr$^{-1}$. Accordingly, the detector will reach a sensitivity to the bbonu-decay half-life of $2.8times10^{25}$ years (90% CL) for an exposure of 100 $mathrm{kg}cdotmathrm{year}$, or $6.0times10^{25}$ years after a run of 3 effective years.
105 - N. Lopez-March 2017
A high pressure xenon gas time projection chamber with electroluminescent amplification (EL HPGXe TPC) searching for the neutrinoless double beta ($0 ubetabeta$) decay offers: excellent energy resolution ($0.5-0.7%$ FWHM at the $Q_{betabeta}$), by am plifying the ionization signal with electroluminescent light, and tracking capabilities, as demonstrated by the NEXT collaboration using two kg-scale prototypes. The NEXT collaboration is building an EL HPGXe TPC capable of holding 100 kg (NEXT-100) of xenon isotopically enriched in ${{}^{136}rm Xe}$. The installation and commissioning of the NEXT-100 detector at the Laboratorio Subterraneo de Canfranc (LSC) is planned for 2018. The current estimated background level for the NEXT-100 detector is of $4times10^{-4}$ counts/keV-kg-yr or less in the energy region of interest. Assuming an energy resolution of 0.75$%$ FWHM at the $Q_{betabeta}$ and a $0 ubetabeta$ signal efficiency of about 28$%$, this gives an expected sensitivity (at 90$%$ CL) to the $0 ubetabeta$ decay half life of $T^{0 u}_{1/2}>6.0times10^{25}$ yr for an exposure of 275 kg yr. A first phase of the NEXT experiment, called NEW, is currently being commissioned at the LSC. The NEW detector is a scale 1:2 in size (1:10 in mass) of the NEXT-100 detector using the same materials and photosensors and will be used to perform a characterization of the $0 ubetabeta$ backgrounds and a measurement of the standard double beta decay with neutrinos (${2 ubetabeta}$). An 8 sigma significance for the ${2 ubetabeta}$ signal in the NEW detector has been estimated for a 100-day run.
We report the results of a search for the neutrinoless double-$beta$ decay (0$ ubetabeta$) of $^{100}$Mo, using the NEMO-3 detector to reconstruct the full topology of the final state events. With an exposure of 34.7 kg.y, no evidence for the 0$ ubet abeta$ signal has been found, yielding a limit for the light Majorana neutrino mass mechanism of $T_{1/2}(0 ubetabeta)>1.1 times 10^{24}$ years (90% C.L.) once both statistical and systematic uncertainties are taken into account. Depending on the Nuclear Matrix Elements this corresponds to an upper limit on the Majorana effective neutrino mass of $< m_{ u} > < 0.3-0.9$ eV (90% C.L.). Constraints on other lepton number violating mechanisms of 0$ ubetabeta$ decays are also given. Searching for high-energy double electron events in all suitable sources of the detector, no event in the energy region [3.2-10] MeV is observed for an exposure of 47 kg.y.
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44.8-kg (29.7 kg enriched >88% in Ge-76) to search for neutrinoless double beta decay in Ge-76. The next genera tion of tonnescale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA DEMONSTRATOR is envisioned to demonstrate a path forward to achieve a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value of 2039 keV. The MAJORANA DEMONSTRATOR follows a modular implementation to be easily scalable to the next generation experiment. First data taken with the DEMONSTRATOR are introduced here.
The Neutrino Experiment with a Xenon TPC (NEXT) searches for the neutrinoless double-beta decay of Xe-136 using high-pressure xenon gas TPCs with electroluminescent amplification. A scaled-up version of this technology with about 1 tonne of enriched xenon could reach in less than 5 years of operation a sensitivity to the half-life of neutrinoless double-beta decay decay better than 1E27 years, improving the current limits by at least one order of magnitude. This prediction is based on a well-understood background model dominated by radiogenic sources. The detector concept presented here represents a first step on a compelling path towards sensitivity to the parameter space defined by the inverted ordering of neutrino masses, and beyond.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا