In this paper, we describe measurements of the response functions of a fiber-based dual- readout calorimeter for pions, protons and multiparticle jets with energies in the range from 10 to 180 GeV. The calorimeter uses lead as absorber material and has a total mass of 1350 kg. It is complemented by leakage counters made of scintillating plastic, with a total mass of 500 kg. The effects of these leakage counters on the calorimeter performance are studied as well. In a separate section, we investigate and compare different methods to measure the energy resolution of a calorimeter. Using only the signals provided by the calorimeter, we demonstrate that our dual-readout calorimeter, calibrated with electrons, is able to reconstruct the energy of proton and pion beam particles to within a few percent at all energies. The fractional widths of the signal distributions for these particles (sigma/E) scale with the beam energy as 30%/sqrt(E), without any additional contributing terms.

قيم البحث

اقرأ أيضاً

723 - M.Danilov 2007
The CALICE collaboration is presently constructing a test hadron calorimeter (HCAL) with 7620 scintillator tiles read out by novel photo-detectors - Silicon Photomultipliers (SiPMs). This prototype is the first device which uses SiPMs on a large scal e. We present the design of the HCAL and report on measured properties of more than 10 thousand SiPMs. We discuss the SiPM efficiency, gain, cross-talk, and noise rate dependence on bias voltage and temperature, including the spread in these parameters. We analyze the reasons for SiPM rejection and present the results of the long term stability studies. The first measurements of the SiPM radiation hardness are presented. We compare properties of SiPM with the properties of similar devices, MRS APD and MPPC. A possibility to make the tiles thinner and to read them out without WLS fibers has been studied.
360 - N.Atanov , V.Baranov , L.Baldini 2019
The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two type s of modules: 1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; 2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of $200 text{M}text{Hz}$ with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of $20 text{krads}$, neutron flux of $10^{12} mathrm{n}(1 text{MeVeq})/text{cm}^2$, magnetic field of $1 text{T}$ and in vacuum level of $10^{-4} text{Torr}$. A description of the readout system and qualification tests is reported.
73 - B.Bilki , John Butler , Ed May 2010
In the context of developing a hadron calorimeter with extremely fine granularity for the application of Particle Flow Algorithms to the measurement of jet energies at a future lepton collider, we report on extensive tests of a small scale prototype calorimeter. The calorimeter contained up to 10 layers of Resistive Plate Chambers (RPCs) with 2560 1 times 1 cm2 readout pads, interleaved with steel absorber plates. The tests included both long-term Cosmic Ray data taking and measurements in particle beams, where the response to broadband muons and to pions and positrons with energies in the range of 1 - 16 GeV was established. Detailed measurements of the chambers efficiency as function of beam intensity have also been performed using 120 GeV protons at varying intensity. The data are compared to simulations based on GEANT4 and to analytical calculations of the rate limitations.
A new method called Neighbor Cell Deposited Energy Ratio (NCDER) is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL).This method was applied to reconstruct the ECAL test beam data for the Alpha Magnetic Spectrometer-02 (AMS-02). The results show that this method can achieve an angular resolution of 7.36pm 0.08 / sqrt(E) oplus 0.28 pm 0.02 degree in the determination of the photons direction, which is much more precise than that obtained with the commonly-adopted Center of Gravity(COG) method (8.4 pm 0.1 /sqrt(E) oplus 0.8pm0.3 degree). Furthermore, since it uses only the properties of electromagnetic showers, this new method could also be used for other type of fine grain sampling calorimeters.
CEPC (Circular Electron and Positron Collider) is a large experiment facility proposed by Chinese particle physics community. One of its running option is being the Higgs factory. Calorimeter is the main part of this experiment to measure the jet ene rgy. Semi-digital hadron calorimeter (SDHCAL) is one of the options for the hadron measurement. GEM detector with its high position resolution and flexible configuration is one of the candidates for the active layer of the SDHCAL. The main purpose of this paper is to provide a feasible readout method for the GEM-based semi-digital hadron calorimeter. A small-scale prototype is designed and implemented, including front-end board (FEB) and data interface board (DIF). The prototype electronics has been tested. The equivalent RMS noise of all channels is below 0.35fC. The dynamic range is up to 500fC and the gain variation is less than 1%. The readout electronics is applied on a double-layer GEM detector with 1cm*1cm readout pad. Result indicates that the electronics works well with the detector. The detection efficiency of MIP is over 95% with 5fC threshold.