ترغب بنشر مسار تعليمي؟ اضغط هنا

Rapid processing of 85Kr/Kr ratios using Atom Trap Trace Analysis

67   0   0.0 ( 0 )
 نشر من قبل Jake Zappala
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English
 تأليف J. C. Zappala




اسأل ChatGPT حول البحث

We report a methodology for measuring 85Kr/Kr isotopic abundances using Atom Trap Trace Analysis (ATTA) that increases sample measurement throughput by over an order of magnitude to 6 samples per 24 hours. The noble gas isotope 85Kr (half-life = 10.7 yr) is a useful tracer for young groundwater in the age range of 5-50 years. ATTA, an efficient and selective laser-based atom counting method, has recently been applied to 85Kr/Kr isotopic abundance measurements, requiring 5-10 microliters of krypton gas at STP extracted from 50-100 L of water. Previously a single such measurement required 48 hours. Our new method demonstrates that we can measure 85Kr/Kr ratios with 3-5% relative uncertainty every 4 hours, on average, with the same sample requirements.

قيم البحث

اقرأ أيضاً

84 - J. C. Zappala 2017
We place a 2.5% limit on the anthropogenic contribution to the modern abundance of 81Kr/Kr in the atmosphere at the 90% confidence level. Due to its simple production and transport in the terrestrial environment, 81Kr (halflife = 230,000 yr) is an id eal tracer for old water and ice with mean residence times in the range of 10^5-10^6 years. In recent years, 81Kr-dating has been made available to the earth science community thanks to the development of Atom Trap Trace Analysis (ATTA), a laser-based atom counting technique. Further upgrades and improvements to the ATTA technique now allow us to demonstrate 81Kr/Kr measurements with relative uncertainties of 1% and place this new limit on anthropogenic 81Kr. As a result of this limit, we have removed a potential systematic constraint for 81Kr-dating.
Observation time is the key parameter for improving the precision of measurements of gravitational quantum states of particles levitating above a reflecting surface. We propose a new method of long confinement in such states of atoms, anti-atoms, neu trons and other particles possessing a magnetic moment. The Earth gravitational field and a reflecting mirror confine particles in the vertical direction. The magnetic field originating from electric current passing through a vertical wire confines particles in the radial direction. Under appropriate conditions, motions along these two directions are decoupled to a high degree. We estimate characteristic parameters of the problem, and list possible systematic effects that limit storage times due to the coupling of the two motions. In the limit of low particle velocities and magnetic fields, precise control of the particle motion and long storage times in the trap can provide ideal conditions for both gravitational, optical and hyperfine spectroscopy: for the sensitive verification of the equivalence principle for antihydrogen atoms; for increasing the accuracy of optical and hyperfine spectroscopy of atoms and antiatoms; for improving constraints on extra fundamental interactions from experiments with neutrons, atoms and antiatoms.
A cold atom interferometer is being developed using 85Rb atoms towards a search for the dark contents of the vacuum, and as a test stand for inertial sensing applications. Here we outline the current status of the experiment and report the observation of Ramsey interference fringes in the apparatus.
Prompt scintillation signals from $^{83m}$Kr calibration sources are a useful metric to calibrate the spatial variation of light collection efficiency and electric field magnitude of a two phase liquid-gas xenon time projection chamber. Because $^{83 m}$Kr decays in two steps, there are two prompt scintillation pulses for each calibration event, denoted S1a and S1b. We study the ratio of S1b to S1a signal sizes in the Particle Identification in Xenon at Yale (PIXeY) experiment and its dependence on the time separation between the two signals ($Delta t$), notably its increase at low $Delta t$. In PIXeY data, the $Delta t$ dependence of S1b/S1a is observed to exhibit two exponential components: one with a time constant of $0.05 pm 0.02mu s$, which can be attributed to processing effects and pulse overlap and one with a time constant of $10.2 pm 2.2mu s$ that increases in amplitude with electric drift field, the origin of which is not yet understood.
119 - D. Beck , K. Blaum , G. Bollen 2008
Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectro meter ISOLTRAP, located at ISOLDE/CERN. The deviations from the ideal magnetic and electric fields are probed by measuring the cyclotron frequency and the reduced cyclotron frequency, respectively, of stored ions as a function of the time between the ejection of ions from the preparation trap and their capture in the precision trap, which influences the energy of their axial motion. The correction parameters are adjusted to minimize the frequency shifts.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا