ترغب بنشر مسار تعليمي؟ اضغط هنا

Ultra Thin 3D Silicon Detector for Plasma Diagnostics at the ITER Tokamak

73   0   0.0 ( 0 )
 نشر من قبل Francisco Garcia
 تاريخ النشر 2016
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

An ultra thin silicon detector called U3DTHIN has been designed and built for neutral particle analyzers (NPA) and thermal neutron detection. The main purpose of this detector is to provide a state-of-the-art solution for detector system of NPAs for the ITER experimental reactor and to be used in combination with a Boron conversion layer for the detection of thermal neutrons. Currently the NPAs are using very thin scintillator - photomultiplier tube, and their main drawbacks are poor energy resolution, intrinsic scintillation nonlinearity, relative low count rate capability and finally poor signal to background discrimination power for the low energy channels. The proposed U3DTHIN detector is based on very thin sensitive substrate which will provide nearly 100% detection efficiency for ions and at the same time very low sensitivity for the neutron and gamma radiation. To achieve a very fast charge collection of the carriers generated by the ions detection a 3D electrode structure[5] has been introduced in the sensitive volume of the detector. One of the most innovative features of these detectors has been the optimal combination of the thin entrance window and the sensitive substrate thickness, to accommodate very large energy dynamic range of the detected ions. An entrance window with a thickness of tens of nanometers together with a sensitive substrate thickness varying from less than 5 microns, to detect the lowest energetic ions to 20 microns for the height ones has been selected after simulations with GEANT4. To increase the signal to background ratio the detector will operate in spectroscopy regime allowing to perform pulse-height analysis. The technology used to fabricate these 3D ultra thin detectors developed at Centro Nacional de Microelectronica in Barcelona and the first signals from an alpha source (241Am) will presented



قيم البحث

اقرأ أيضاً

155 - A. Seiden , H. Ren , Y. Jin 2020
Ultra-Fast Silicon Detectors (UFSDs) are n-in-p silicon detectors that implement moderate gain (typically 5 to 25) using a thin highly doped p++ layer between the high resistivity p-bulk and the junction of the sensor. The presence of gain allows exc ellent time measurement for impinging minimum ionizing charged particles. An important design consideration is the sensor thickness, which has a strong impact on the achievable time resolution. We present the result of measurements for LGADs of thickness between 20 micro-m and 50 micro-m. The data are fit to a formula that captures the impact of both electronic jitter and Landau fluctuations on the time resolution. The data illustrate the importance of having a saturated electron drift velocity and a large signal-to-noise in order to achieve good time resolution. Sensors of 20 micro-m thickness offer the potential of 10 to 15 ps time resolution per measurement, a significant improvement over the value for the 50 micro-m sensors that have been typically used to date.
The BiPo-3 detector, running in the Canfranc Underground Laboratory (Laboratorio Subterraneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measuring ultra low natural radionuclide contaminations of $^{208}$Tl ($^{2 32}$Th chain) and $^{214}$Bi ($^{238}$U chain) in thin materials. The total sensitive surface area of the detector is 3.6 m$^2$. The detector has been developed to measure radiopurity of the selenium double $beta$-decay source foils of the SuperNEMO experiment. In this paper the design and performance of the detector, and results of the background measurements in $^{208}$Tl and $^{214}$Bi, are presented, and validation of the BiPo-3 measurement with a calibrated aluminium foil is discussed. Results of the $^{208}$Tl and $^{214}$Bi activity measurements of the first enriched $^{82}$Se foils of the double $beta$-decay SuperNEMO experiment are reported. The sensitivity of the BiPo-3 detector for the measurement of the SuperNEMO $^{82}$Se foils is $mathcal{A}$($^{208}$Tl) $<2$ $mu$Bq/kg (90% C.L.) and $mathcal{A}$($^{214}$Bi) $<140$ $mu$Bq/kg (90% C.L.) after 6 months of measurement.
To avoid reflectivity losses in ITER optical diagnostic systems, plasma sputtering of metallic First Mirrors is foreseen in order to remove deposits coming from the main wall (mainly beryllium and tungsten). Therefore plasma cleaning has to work on l arge mirrors (up to a size of 200*300 mm) and under the influence of strong magnetic fields (several Tesla). This work presents the results of plasma cleaning of aluminium and aluminium oxide (used as beryllium proxy) deposited on molybdenum mirrors. Using radio frequency (13.56 MHz) argon plasma, the removal of a 260 nm mixed aluminium/aluminium oxide film deposited by magnetron sputtering on a mirror (98 mm diameter) was demonstrated. 50 nm of pure aluminium oxide were removed from test mirrors (25 mm diameter) in a magnetic field of 0.35 T for various angles between the field lines and the mirrors surfaces. The cleaning efficiency was evaluated by performing reflectivity measurements, Scanning Electron Microscopy and X-ray Photoelectron Spectroscopy.
High-intensity secondary beams play a vital role in todays particle physics and materials science research and require suitable detection techniques to adjust beam characteristics to optimally match experimental conditions. To this end we have develo ped a non-invasive, ultra-thin, CsI(Tl) luminophore foil detector system, based on CCD-imaging. We have used this to quantify the beam characteristics of an intensity-frontier surface muon beam used for next-generation charged lepton-flavour violation (cLFV) search experiments at the Paul Scherrer Institut (PSI) and to assess the possible use for a future High-intensity Muon Beam (HiMB-project), currently under study at PSI. An overview of the production and intrinsic characteristics of such foils is given and their application in a high-intensity beam environment.
The spectrum of laser-plasma generated X-rays is very important, it characterizes electron dynamics in plasma and is basic for applications. However, the accuracies and efficiencies of existing methods to diagnose the spectrum of laser-plasma based X -ray pulse are not very high, especially in the range of several hundred keV. In this study, a new method based on electron tracks detection to measure the spectrum of laser-plasma produced X-ray pulses is proposed and demonstrated. Laser-plasma generated X-rays are scattered in a multi-pixel silicon tracker. Energies and scattering directions of Compton electrons can be extracted from the response of the detector, and then the spectrum of X-rays can be reconstructed. Simulations indicate that the energy resolution of this method is approximately 20% for X-rays from 200 to 550 keV for a silicon-on-insulator pixel detector with 12 $rm mu$m pixel pitch and 500 $rm mu$m depletion region thickness. The results of a proof-of-principle experiment based on a Timepix3 detector are also shown.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا