ترغب بنشر مسار تعليمي؟ اضغط هنا

Cross-spectrum noise measurements at 4 K to minimize power-splitter anti-correlation effect

100   0   0.0 ( 0 )
 نشر من قبل Archita Hati
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We report an accurate measurement of the phase noise of a thermally limited electronic oscillator at 300 K. By thermally limited we mean that the white signal-to-noise ratio of the oscillator is at or near the level generated by the thermal noise of the 50 ohm source resistor. The measurement is devoid of the anti-correlation effect that originates from the common mode power splitter in a cross-spectrum technique. The anti-correlation effect is mitigated by cooling the power splitter to a liquid helium temperature (4 K). The measurements in this paper are the first proof of theoretical claims that additive thermal noise from the splitter can be reduced significantly with cryogenic cooling and this can eliminate any anti-correlated noise introduced by use of the two-channel cross-spectrum technique. We also confirm measurements of partial anti-correlation error of (-1.3 +/- 0.6) dB that agree with theory when the splitter is at liquid nitrogen temperature of 77 K.

قيم البحث

اقرأ أيضاً

Crystalline optical cavities are the foundation of todays state-of-the-art ultrastable lasers. Building on our previous silicon cavity effort, we now achieve the fundamental thermal noise-limited stability for a 6 cm long silicon cavity cooled to 4 K elvin, reaching $6.5times10^{-17}$ from 0.8 to 80 seconds. We also report for the first time a clear linear dependence of the cavity frequency drift on the incident optical power. The lowest fractional frequency drift of $-3times10^{-19}$/s is attained at a transmitted power of 40 nW, with an extrapolated drift approaching zero in the absence of optical power. These demonstrations provide a promising direction to reach a new performance domain for stable lasers, with stability better than $1times10^{-17}$ and fractional linear drift below $1times10^{-19}$/s.
Research reactors host a wide range of activities that make use of the intense neutron fluxes generated at these facilities. Recent interest in performing measurements with relatively low event rates, e.g. reactor antineutrino detection, at these fac ilities necessitates a detailed understanding of background radiation fields. Both reactor-correlated and naturally occurring background sources are potentially important, even at levels well below those of importance for typical activities. Here we describe a comprehensive series of background assessments at three high-power research reactors, including $gamma$-ray, neutron, and muon measurements. For each facility we describe the characteristics and identify the sources of the background fields encountered. The general understanding gained of background production mechanisms and their relationship to facility features will prove valuable for the planning of any sensitive measurement conducted therein.
We present the first experimental study of a new type of power recycling microwave interferometer designed for low noise measurements. This system enhances sensitivity to phase fluctuations in a Device Under Test, independent of input power levels. T he single sideband thermal white phase noise floor of the system has been lowered by 8 dB (reaching -185 dBc/Hz at 1 kHz offset frequency) at relatively low power levels (13 dBm).
We estimate the power spectrum of SZ(Sunyaev-Zeldovich)-effect-induced temperature fluctuations on sub-degree scales by using the cross correlation between the three-year WMAP maps and 2MASS galaxy distribution. We produced the SZ effect maps by hydr odynamic simulation samples of the $Lambda$CDM model, and show that the SZ effect temperature fluctuations are highly non-Gaussian. The PDF of the temperature fluctuations has a long tail. More than 70% power of the SZ effect temperature fluctuations attributes to top $sim 1%$ wavelet modes (long tail events). On the other hand, the CMB temperature fluctuations basically are Gaussian. Although the mean power of CMB temperature fluctuations on sub-degree scales is much higher than that of SZ effect map, the SZ effect temperature fluctuations associated with top 2MASS clusters is comparable to the power of CMB temperature fluctuations on the same scales. Thus, from noisy WMAP maps, one can have a proper estimation of the SZ effect power at the positions of the top 2MASS clusters. The power spectrum given by these top wavelet modes is useful to constrain the parameter of density fluctuations amplitude $sigma_8$. We find that the power spectrum of these top wavelet modes of SZ effect on sub-degree scales basically is consistent with the simulation maps produced with $sigma_8=0.84$. The simulation samples of $sigma_8=0.74$ show, however, significant deviation from detected SZ power spectrum. It can be ruled out with confidence level 99% if all other cosmological parameters are the same as that given by the three-year WMAP results.
For photon-counting applications at ultraviolet wavelengths, there are currently no detectors that combine high efficiency (> 50%), sub-nanosecond timing resolution, and sub-Hz dark count rates. Superconducting nanowire single-photon detectors (SNSPD s) have seen success over the past decade for photon-counting applications in the near-infrared, but little work has been done to optimize SNSPDs for wavelengths below 400 nm. Here, we describe the design, fabrication, and characterization of UV SNSPDs operating at wavelengths between 250 and 370 nm. The detectors have active areas up to 56 ${mu}$m in diameter, 70 - 80% efficiency, timing resolution down to 60 ps FWHM, blindness to visible and infrared photons, and dark count rates of ~ 0.25 counts/hr for a 56 ${mu}$m diameter pixel. By using the amorphous superconductor MoSi, these UV SNSPDs are also able to operate at temperatures up to 4.2 K. These performance metrics make UV SNSPDs ideal for applications in trapped-ion quantum information processing, lidar studies of the upper atmosphere, UV fluorescent-lifetime imaging microscopy, and photon-starved UV astronomy.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا