ترغب بنشر مسار تعليمي؟ اضغط هنا

A comparison of untagged gamma-ray and tagged-neutron yields from 241AmBe and 238PuBe sources

48   0   0.0 ( 0 )
 نشر من قبل Kevin Fissum
 تاريخ النشر 2016
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Untagged gamma-ray and tagged-neutron yields from 241AmBe and 238PuBe mixed-field sources have been measured. Gamma-ray spectroscopy measurements from 1 - 5 MeV were performed in an open environment using a CeBr3 detector and the same experimental conditions for both sources. The shapes of the distributions are very similar and agree well with previous data. Tagged-neutron measurements from 2 - 6 MeV were performed in a shielded environment using a NE-213 liquid-scintillator detector for the neutrons and a YAP(Ce) detector to tag the 4.44 MeV gamma-rays associated with the de-excitation of the first excited state of 12C. Again, the same experimental conditions were used for both sources. The shapes of these distributions are also very similar and agree well with previous data, each other, and the ISO recommendation. Our 238PuBe source provides approximately 2.6 times more 4.44 MeV gamma-rays and 2.4 times more neutrons over the tagged-neutron energy range, the latter in reasonable agreement with the original full-spectrum source-calibration measurements performed at the time of their acquisition.



قيم البحث

اقرأ أيضاً

79 - G. Bison , M. Daum , K. Kirch 2016
Ultracold neutrons (UCNs) are key for precision studies of fundamental parameters of the neutron and in searches for new CP violating processes or exotic interactions beyond the Standard Model of particle physics. The most prominent example is the se arch for a permanent electric dipole moment of the neutron (nEDM). We have performed an experimental comparison of the leading UCN sources currently operating. We have used a standard UCN storage bottle with a volume of 32 liters, comparable in size to nEDM experiments, which allows us to compare the UCN density available at a given beam port.
69 - Y. Ashida , H. Nagata , Y. Koshio 2018
Fast neutrons are a large background to measurements of gamma-rays emitted from excited nuclei, such that detectors which can efficiently distinguish between the two are essential. In this paper we describe the separation of gamma-rays from neutrons with the pulse shape information of the CsI(Tl) scintillator, using a fast neutron beam and several gamma-ray sources. We find that a figure of merit optimized for this separation takes on large and stable values (nearly 4) between 5 and 10 MeV of electron equivalent deposited energy, the region of most interest to the study of nuclear de-excitation gamma-rays. Accordingly this work demonstrates the ability of CsI(Tl) scintillators to reject neutron backgrounds to gamma-ray measurements at these energies.
161 - Yang yun , Liu guofu , Yang jun 2013
A novel algorithm for the discrimination of neutron and {gamma}-ray with wavelet transform modulus maximum (WTMM) in an organic scintillation has been investigated. Voltage pulses arising from a BC501A organic liquid scintillation detector in a mixed radiation field have been recorded with a fast digital sampling oscilloscope. The performances of most pulse shape discrimination methods in scintillation detection systems using time-domain features of the pulses are affected intensively by noise. However, the WTMM method using frequency-domain features exhibits a strong insensitivity to noise and can be used to discriminate neutron and {gamma}-ray events based on their different asymptotic decay trend between the positive modulus maximum curve and the negative modulus maximum curve in the scale-space plane. This technique has been verified by the corresponding mixed-field data assessed by the time-of-flight (TOF) method and the frequency gradient analysis (FGA) method. It is shown that the characterization of neutron and gamma achieved by the discrimination method based on WTMM is consistent with that afforded by TOF and better than FGA. Moreover, because the WTMM method is it self presented to eliminate the noise, there is no need to make any pretreatment for the pulses.
A first comparison has been made between the pulse-shape discrimination characteristics of a novel $^{4}$He-based pressurized scintillation detector and a NE-213 liquid-scintillator reference detector using an Am/Be mixed-field neutron and gamma-ray source and a high-resolution scintillation-pulse digitizer. In particular, the capabilities of the two fast neutron detectors to discriminate between neutrons and gamma-rays were investigated. The NE-213 liquid-scintillator reference cell produced a wide range of scintillation-light yields in response to the gamma-ray field of the source. In stark contrast, due to the size and pressure of the $^{4}$He gas volume, the $^{4}$He-based detector registered a maximum scintillation-light yield of 750~keV$_{ee}$ to the same gamma-ray field. Pulse-shape discrimination for particles with scintillation-light yields of more than 750~keV$_{ee}$ was excellent in the case of the $^{4}$He-based detector. Above 750~keV$_{ee}$ its signal was unambiguously neutron, enabling particle identification based entirely upon the amount of scintillation light produced.
The gamma-ray background in the indoor environment has been measured up to 3 MeV to evaluate the feasibility of studying low cross-section (nanobarn to picobarn range) astrophysical reactions at the Facility for Research in Experimental Nuclear Astro physics (FRENA), Saha Institute of Nuclear Physics, Kolkata. An n-type coaxial HPGe detector with 20% relative efficiency has been placed at different locations in the accelerator and beam halls for the measurement. The measured activity has been compared with that at two laboratories (with standard brick walls) with and without passive and active radiation shielding. As the halls at FRENA are well shielded by concrete, the contribution of the shielding in indoor gamma-ray background has been delineated by simulation using a 4p-geometry model.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا