Wavelet transform is proposed in this paper for detection of islanding and fault disturbances distributed generation (DG) based power system. An IEEE 14-bus system with DG penetration is considered for the detection of disturbances under different operating conditions. The power system is a hybrid combination of photovoltaic, and wind energy system connected to different buses with different level of penetration. The voltage signal is retrieved at the point of common coupling (PCC) and processed through wavelet transform to detect the disturbances. Further, energy and standard deviation (STD) as performance indices are evaluated and compared with a suitable threshold in order to analyze a disturbance condition. Again, a comparative analysis between the existing and proposed detection is studied to prove the better performance of wavelet transform.

قيم البحث

اقرأ أيضاً

Uninterruptible power supply is the main motive of power utility companies that motivate them for identifying and locating the different types of faults as quickly as possible to protect the power system prevent complete power black outs using intell igent techniques. Thus, the present research work presents a novel method for detection of fault disturbances based on Wavelet Transform (WT) and Independent Component Analysis (ICA). The voltage signal is taken offline under fault conditions and is being processed through wavelet and ICA for detection. The time-frequency resolution from WT transform detects the fault initiation instant in the signal. Again, a performance index is calculated from independent component analysis under fault condition which is used to detect the fault disturbance in the voltage signal. The proposed approach is tested to be robust enough under various operating scenarios like without noise, with 20-dB noise and variation in frequency. Further, the detection study is carried out using a performance index, energy content, by applying the existing Fourier transform (FT), short time Fourier transform (STFT) and the proposed wavelet transform. Fault disturbances are detected if the energy calculated in each scenario is greater than the corresponding threshold value. The fault detection study is simulated in MATLAB/Simulink for a typical power system.
A significant portion of the literature on fault localization assumes (more or less explicitly) that there are sufficient reliable measurements to guarantee that the system is observable. While several heuristics exist to break the observability barr ier, they mostly rely on recognizing spatio-temporal patterns, without giving insights on how the performance are tied with the system features and the sensor deployment. In this paper, we try to fill this gap and investigate the limitations and performance limits of fault localization using Phasor Measurement Units (PMUs), in the low measurements regime, i.e., when the system is unobservable with the measurements available. Our main contribution is to show how one can leverage the scarce measurements to localize different type of distribution line faults (three-phase, single-phase to ground, ...) at the level of sub-graph, rather than with the resolution of a line. We show that the resolution we obtain is strongly tied with the graph clustering notion in network science.
In this work, we performed a thorough comparative analysis on a radio frequency (RF) based drone detection and identification system (DDI) under wireless interference, such as WiFi and Bluetooth, by using machine learning algorithms, and a pre-traine d convolutional neural network-based algorithm called SqueezeNet, as classifiers. In RF signal fingerprinting research, the transient and steady state of the signals can be used to extract a unique signature from an RF signal. By exploiting the RF control signals from unmanned aerial vehicles (UAVs) for DDI, we considered each state of the signals separately for feature extraction and compared the pros and cons for drone detection and identification. Using various categories of wavelet transforms (discrete wavelet transform, continuous wavelet transform, and wavelet scattering transform) for extracting features from the signals, we built different models using these features. We studied the performance of these models under different signal to noise ratio (SNR) levels. By using the wavelet scattering transform to extract signatures (scattergrams) from the steady state of the RF signals at 30 dB SNR, and using these scattergrams to train SqueezeNet, we achieved an accuracy of 98.9% at 10 dB SNR.
For additive actuator and sensor faults, we propose a systematic method to design a state-space fault estimation filter directly from Markov parameters identified from fault-free data. We address this problem by parameterizing a system-inversion-base d fault estimation filter with the identified Markov parameters. Even without building an explicit state-space plant model, our novel approach still allows the filter gain design for stabilization and suboptimal $mathcal{H}_2$ performance. This design freedom cannot be achieved by other existing data-driven fault estimation filter designs so far. Another benefit of our proposed design is the convenience of determining the state order: a higher state order of the filter leads to better estimation performance, at the cost of heavier computational burden. In contrast, order determination is cumbersome when using an identified state-space plant model for the filter design, because of the complicated propagation of the model mismatch into the fault estimation errors. Simulations using an unstable aircraft system illustrate the effectiveness of the proposed new method.
61 - Manojit Roy 1999
Submission withdrawn because the authors erroneously submitted a revised version as a new submission, see nlin.CD/0002028.