ترغب بنشر مسار تعليمي؟ اضغط هنا

Fast Backprojection Techniques for High Resolution Tomography

99   0   0.0 ( 0 )
 نشر من قبل Nikolay Koshev
 تاريخ النشر 2016
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Fast image reconstruction techniques are becoming important with the increasing number of scientific cases in high resolution micro and nano tomography. The processing of the large scale three-dimensional data demands new mathematical tools for the tomographic reconstruction task because of the big computational complexity of most current algorithms as the sizes of tomographic data grow with the development of more powerful acquisition hardware and more refined scientific needs. In the present paper we propose a new fast back-projection operator for the processing of tomographic data and compare it against other fast reconstruction techniques.



قيم البحث

اقرأ أيضاً

Current 3D photoacoustic tomography (PAT) systems offer either high image quality or high frame rates but are not able to deliver high spatial and temporal resolution simultaneously, which limits their ability to image dynamic processes in living tis sue. A particular example is the planar Fabry-Perot (FP) scanner, which yields high-resolution images but takes several minutes to sequentially map the photoacoustic field on the sensor plane, point-by-point. However, as the spatio-temporal complexity of many absorbing tissue structures is rather low, the data recorded in such a conventional, regularly sampled fashion is often highly redundant. We demonstrate that combining variational image reconstruction methods using spatial sparsity constraints with the development of novel PAT acquisition systems capable of sub-sampling the acoustic wave field can dramatically increase the acquisition speed while maintaining a good spatial resolution: First, we describe and model two general spatial sub-sampling schemes. Then, we discuss how to implement them using the FP scanner and demonstrate the potential of these novel compressed sensing PAT devices through simulated data from a realistic numerical phantom and through measured data from a dynamic experimental phantom as well as from in-vivo experiments. Our results show that images with good spatial resolution and contrast can be obtained from highly sub-sampled PAT data if variational image reconstruction methods that describe the tissues structures with suitable sparsity-constraints are used. In particular, we examine the use of total variation regularization enhanced by Bregman iterations. These novel reconstruction strategies offer new opportunities to dramatically increase the acquisition speed of PAT scanners that employ point-by-point sequential scanning as well as reducing the channel count of parallelized schemes that use detector arrays.
The problem of image reconstruction in thermoacoustic tomography requires inversion of a generalized Radon transform, which integrates the unknown function over circles in 2D or spheres in 3D. The paper investigates implementation of the recently dis covered backprojection type inversion formulas for the case of spherical acquisition in 3D. A numerical simulation of the data acquisition with subsequent reconstructions are made for the Defrise phantom as well as for some other phantoms. Both full and partial scan situations are considered. The results are compared with the implementation of a previously used approximate inversion formula.
107 - Simon Rabanser , Lukas Neumann , 2018
The development of accurate and efficient image reconstruction algorithms is a central aspect of quantitative photoacoustic tomography (QPAT). In this paper, we address this issues for multi-source QPAT using the radiative transfer equation (RTE) as accurate model for light transport. The tissue parameters are jointly reconstructed from the acoustical data measured for each of the applied sources. We develop stochastic proximal gradient methods for multi-source QPAT, which are more efficient than standard proximal gradient methods in which a single iterative update has complexity proportional to the number applies sources. Additionally, we introduce a completely new formulation of QPAT as multilinear (MULL) inverse problem which avoids explicitly solving the RTE. The MULL formulation of QPAT is again addressed with stochastic proximal gradient methods. Numerical results for both approaches are presented. Besides the introduction of stochastic proximal gradient algorithms to QPAT, we consider the new MULL formulation of QPAT as main contribution of this paper.
Filtered backprojection (FBP) is an efficient and popular class of tomographic image reconstruction methods. In photoacoustic tomography, these algorithms are based on theoretically exact analytic inversion formulas which results in accurate reconstr uctions. However, photoacoustic measurement data are often incomplete (limited detection view and sparse sampling), which results in artefacts in the images reconstructed with FBP. In addition to that, properties such as directivity of the acoustic detectors are not accounted for in standard FBP, which affects the reconstruction quality, too. To account for these issues, in this papers we propose to improve FBP algorithms based on machine learning techniques. In the proposed method, we include additional weight factors in the FBP, that are optimized on a set of incomplete data and the corresponding ground truth photoacoustic source. Numerical tests show that the learned FBP improves the reconstruction quality compared to the standard FBP.
111 - Osnath Assayag 2012
We present a benchmark pilot study in which high-resolution Full-Field Optical Coherence Tomography (FF-OCT) is used to image human breast tissue and is evaluated to assess its ability to aid the pathologists management of intra-operative diagnoses. Our aim included evaluating the safety of FF-OCT on human tissue and determining the concordance between the images obtained with routinely prepared histopathological material. The compact device used for this study provides a 2 {mu}m-lateral and a 1 {mu}m-axial resolution, and is able to scan a 1.5cm^2 specimen in about 7 minutes. 75 breast specimens obtained from 22 patients have been imaged. Because the contrast in the images is generated by endogenous tissue components, no biological, contrast agents or specimen preparation is required. We characterized the major architectural features and tissue structures of benign breast tissue, including adipocytes, fibrous stroma, lobules and ducts. We subsequently characterized features resulting from their pathological modification and developed a decision tree for diagnosis. Two breast pathologists applied these criteria, resulting in a demonstrable ability to distinguish between normal or benign tissue, in situ and invasive carcinomas using FF-OCT images, with a sensitivity of 97% and 90%, respectively, and specificity of 74% and 77% respectfully. FF-OCT shows great potential for the evaluation of human tissue and its characterization as normal/benign vs. lesional, for numerous ex-vivo clinical use-cases. Its high imaging accuracy for in-situ and invasive carcinoma paves the way for applications where a fast architectural assessment could improve the core needle biopsy workflow, tumor margin assessments, and provides quality assurance for tissue acquired for clinical care and research.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا