ترغب بنشر مسار تعليمي؟ اضغط هنا

Compact Measurement Station for Low Energy Proton Beams

96   0   0.0 ( 0 )
 نشر من قبل Gokhan Unel
 تاريخ النشر 2016
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

A compact, remote controlled, cost efficient diagnostic station has been developed to measure the charge, the profile and the emittance for low energy proton beams. It has been installed and tested in the proton beam line of the Project Prometheus at SANAEM of the Turkish Atomic Energy Authority.

قيم البحث

اقرأ أيضاً

213 - M. Tajima , N. Kuroda , C. Amsler 2019
A low energy antiproton transport from the ASACUSA antiproton accumulation trap (MUSASHI trap) to the antihydrogen production trap (double cusp trap) is developed. The longitudinal antiproton energy spread after the transport line is 0.23 +- 0.02 eV, compared with 15 eV with a previous method used in 2012. This reduction is achieved by an adiabatic transport beamline with several pulse-driven coaxial coils. Antihydrogen atoms are synthesized by directly injecting the antiprotons into a positron plasma, resulting in the higher production rate.
A preliminary study of the Energy Production Demonstrator (EPD) concept - a solid heavy metal target irradiated by GeV-range intense proton beams and producing more energy than consuming - is carried out. Neutron production, fission, energy depositio n, energy gain, testing volume and helium production are simulated with the MARS15 code for tungsten, thorium, and natural uranium targets in the proton energy range 0.5 to 120 GeV. This study shows that the proton energy range of 2 to 4 GeV is optimal for both a natU EPD and the tungsten-based testing station that would be the most suitable for proton accelerator facilities. Conservative estimates, not including breeding and fission of plutonium, based on the simulations suggest that the proton beam current of 1 mA will be sufficient to produce 1 GW of thermal output power with the natU EPD while supplying < 8% of that power to operate the accelerator. The thermal analysis shows that the concept considered has a problem due to a possible core meltdown; however, a number of approaches (a beam rastering, in first place) are suggested to mitigate the issue. The efficiency of the considered EPD as a Materials Test Station (MTS) is also evaluated in this study.
Based on a paper published in 2019 by the FCAL Collaboration, this talk is giving an update of the Collaborations effort to design prototype of highly compact calorimeter to instrument the very forward region of a detector at future $e^+e^-$ collider s. A luminometer prototype, based on sub-millimeter thick detector planes, is tested with an electron-beam of energy 1-5 GeV. The effective Moliere radius of the prototype comprising eight detector planes was measured to be (8.1 +/- 0.1 (stat.) +/- 0.3 (syst.))mm, and the result is well reproduced by the Monte Carlo simulation.
113 - P. Klag , P. Achenbach , M. Biroth 2018
A novel interferometric method for absolute beam energy measurement is under development at MAMI. At the moment, the method is tested and optimized at an energy of 195 MeV. Despite the very small statistical uncertainty of the method, systematic effe cts have limited the overall accuracy. Recently, a measurement has been performed dedicated to the evaluation of these effects. This report comprises a description of the method and results of the recent data taking period.
The design, construction, and characterization of the Multi-Sampling Ionization Chamber, MuSIC@Indiana, are described. This detector provides efficient and accurate measurement of the fusion cross-section at near-barrier energies. The response of the detector to low-intensity beams of $^{17,18}$O, $^{19}$F, $^{23}$Na, $^{24,26}$Mg, $^{27}$Al, and $^{28}$Si at E$_{lab}$ = 50-60 MeV was examined. MuSIC@Indiana was commissioned by measuring the $^{18}$O+$^{12}$C fusion excitation function for 11 $<$ E$_{cm}$ $<$ 20 MeV using CH$_{4}$ gas. A simple, effective analysis cleanly distinguishes proton capture and two-body scattering events from fusion on carbon. With MuSIC@Indiana, measurement of 15 points on the excitation function for a single incident beam energy is achieved. The resulting excitation function is shown to be in good agreement with literature data
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا