ترغب بنشر مسار تعليمي؟ اضغط هنا

Background Evaluation for the Neutron Sources in the Daya Bay Experiment

82   0   0.0 ( 0 )
 نشر من قبل Wenqiang Gu
 تاريخ النشر 2015
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We present an evaluation of the background induced by $^{241}$Am-$^{13}$C neutron calibration sources in the Daya Bay reactor neutrino experiment. As a significant background for electron-antineutrino detection at 0.26$pm$0.12 per detector per day on average, it has been estimated by a Monte Carlo simulation that was benchmarked by a special calibration data set. This dedicated data set also provided the energy spectrum of the background.



قيم البحث

اقرأ أيضاً

206 - J. Wilhelmi , R. Bopp , R. Brown 2014
We describe the design, installation, and operation of a purification system that is able to provide large volumes of high purity ASTM (D1193-91) Type-I water to a high energy physics experiment. The water environment is underground in a lightly seal ed system, and this provides significant challenges to maintaining high purity in the storage pools, each of which contains several thousand cubic meters. High purity is dictated by the need for large optical absorption length, which is critical for the operation of the experiment. The system is largely successful, and the water clarity criteria are met. We also include a discussion of lessons learned.
The Daya Bay experiment was the first to report simultaneous measurements of reactor antineutrinos at multiple baselines leading to the discovery of $bar{ u}_e$ oscillations over km-baselines. Subsequent data has provided the worlds most precise meas urement of $rm{sin}^22theta_{13}$ and the effective mass splitting $Delta m_{ee}^2$. The experiment is located in Daya Bay, China where the cluster of six nuclear reactors is among the worlds most prolific sources of electron antineutrinos. Multiple antineutrino detectors are deployed in three underground water pools at different distances from the reactor cores to search for deviations in the antineutrino rate and energy spectrum due to neutrino mixing. Instrumented with photomultiplier tubes (PMTs), the water pools serve as shielding against natural radioactivity from the surrounding rock and provide efficient muon tagging. Arrays of resistive plate chambers over the top of each pool provide additional muon detection. The antineutrino detectors were specifically designed for measurements of the antineutrino flux with minimal systematic uncertainty. Relative detector efficiencies between the near and far detectors are known to better than 0.2%. With the unblinding of the final two detectors baselines and target masses, a complete description and comparison of the eight antineutrino detectors can now be presented. This paper describes the Daya Bay detector systems, consisting of eight antineutrino detectors in three instrumented water pools in three underground halls, and their operation through the first year of eight detector data-taking.
In the Daya Bay Reactor Neutrino Experiment 960 20-cm-diameter waterproof photomultiplier tubes are used to instrument three water pools as Cherenkov detectors for detecting cosmic-ray muons. Of these 960 photomultiplier tubes, 341 are recycled from the MACRO experiment. A systematic program was undertaken to refurbish them as waterproof assemblies. In the context of passing the water leakage check, a success rate better than 97% was achieved. Details of the design, fabrication, testing, operation, and performance of these waterproofed photomultiplier-tube assemblies are presented.
The Daya Bay Reactor Neutrino Experiment has measured the last unknown neutrino mixing angle, {theta}13, to be non-zero at the 7.7{sigma} level. This is the most precise measurement to {theta}13 to date. To further enhance the understanding of the re sponse of the antineutrino detectors (ADs), a detailed calibration of an AD with the Manual Calibration System (MCS) was undertaken during the summer 2012 shutdown. The MCS is capable of placing a radioactive source with a positional accuracy of 25 mm in R direction, 20 mm in Z axis and 0.5{deg} in {Phi} direction. A detailed description of the MCS is presented followed by a summary of its performance in the AD calibration run.
123 - F.Bellini , C.Bucci , S.Capelli 2009
CUORE is a 1 ton scale cryogenic experiment aiming at the measurement of the Majorana mass of the electron neutrino. The detector is an array of 988 TeO2 bolometers used for a calorimetric detection of the two electrons emitted in the BB0n of 130Te. The sensitivity of the experiment to the lowest Majorana mass is determined by the rate of background events that can mimic a BB0n. In this paper we investigate the contribution of external sources i.e. environmental gammas, neutrons and cosmic ray muons to the CUORE background and show that the shielding setup designed for CUORE guarantees a reduction of this external background down to a level <1.0E-02 c/keV/kg/y at the Q-value, as required by the physical goal of the experiment.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا