ترغب بنشر مسار تعليمي؟ اضغط هنا

Phase Coherent Link of an Atomic Clock to a Self-Referenced Microresonator Frequency Comb

68   0   0.0 ( 0 )
 نشر من قبل Pascal Del'Haye
 تاريخ النشر 2015
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The counting and control of optical cycles of light has become common with modelocked laser frequency combs. But even with advances in laser technology, modelocked laser combs remain bulk-component devices that are hand-assembled. In contrast, a frequency comb based on the Kerr-nonlinearity in a dielectric microresonator will enable frequency comb functionality in a micro-fabricated and chip-integrated package suitable for use in a wide-range of environments. Such an advance will significantly impact fields ranging from spectroscopy and trace gas sensing, to astronomy, communications, atomic time keeping and photonic data processing. Yet in spite of the remarkable progress shown over the past years, microresonator frequency combs (microcombs) have still been without the key function of direct f-2f self-referencing and phase-coherent frequency control that will be critical for enabling their full potential. Here we realize these missing elements using a low-noise 16.4 GHz silicon chip microcomb that is coherently broadened from its initial 1550 nm wavelength and subsequently f-2f self-referenced and phase-stabilized to an atomic clock. With this advance, we not only realize the highest repetition rate octave-span frequency comb ever achieved, but we highlight the low-noise microcomb properties that support highest atomic clock limited frequency stability.

قيم البحث

اقرأ أيضاً

Optical-frequency combs enable measurement precision at the 20th digit, and accuracy entirely commensurate with their reference oscillator. A new direction in experiments is the creation of ultracompact frequency combs by way of nonlinear parametric optics in microresonators. We refer to these as microcombs, and here we report a silicon-chip-based microcomb optical clock that phase-coherently converts an optical-frequency reference to a microwave signal. A low-noise comb spectrum with 25 THz span is generated with a 2 mm diameter silica disk and broadening in nonlinear fiber. This spectrum is stabilized to rubidium frequency references separated by 3.5 THz by controlling two teeth 108 modes apart. The optical clocks output is the electronically countable 33 GHz microcomb line spacing, which features an absolute stability better than the rubidium transitions by the expected factor of 108. Our work demonstrates the comprehensive set of tools needed for interfacing microcombs to state-of-the-art optical clocks.
254 - Scott B. Papp , Pascal DelHaye , 2013
We have investigated parametric seeding of a microresonator frequency comb (microcomb) by way of a pump laser with two electro-optic-modulation sidebands. We show that the pump-sideband spacing is precisely replicated throughout the microcombs optica l spectrum, and we demonstrate a record absolute line-spacing stability for microcombs of $1.6times10^{-13}$ at 1 s. The spectrum of a parametric comb is complex, and often non-equidistant subcombs are observed. Our results demonstrate that parametric seeding can not only control the subcombs, but can lead to the generation of a strictly equidistant microcomb spectrum.
Optical frequency combs provide equidistant frequency markers in the infrared, visible and ultra-violet and can link an unknown optical frequency to a radio or microwave frequency reference. Since their inception frequency combs have triggered major advances in optical frequency metrology and precision measurements and in applications such as broadband laser-based gas sensing8 and molecular fingerprinting. Early work generated frequency combs by intra-cavity phase modulation while to date frequency combs are generated utilizing the comb-like mode structure of mode-locked lasers, whose repetition rate and carrier envelope phase can be stabilized. Here, we report an entirely novel approach in which equally spaced frequency markers are generated from a continuous wave (CW) pump laser of a known frequency interacting with the modes of a monolithic high-Q microresonator13 via the Kerr nonlinearity. The intrinsically broadband nature of parametric gain enables the generation of discrete comb modes over a 500 nm wide span (ca. 70 THz) around 1550 nm without relying on any external spectral broadening. Optical-heterodyne-based measurements reveal that cascaded parametric interactions give rise to an optical frequency comb, overcoming passive cavity dispersion. The uniformity of the mode spacing has been verified to within a relative experimental precision of 7.3*10(-18).
We demonstrate control and stabilization of an optical frequency comb generated by four-wave mixing in a monolithic microresonator with a mode spacing in the microwave regime (86 GHz). The comb parameters (mode spacing and offset frequency) are contr olled via the power and the frequency of the pump laser, which constitutes one of the comb modes. Furthermore, generation of a microwave beat note at the combs mode spacing frequency is presented, enabling direct stabilization to a microwave frequency standard.
A quiet point, an operating point of pump-resonance detuning that minimizes frequency fluctuation due to nonlinear effects inside a resonator, has been employed for phase noise reduction of a soliton Kerr microresonator frequency comb (microcomb). Na turally, it is expected that the use of the point will also improve performances of a microcomb in terms of frequency stability and faithfulness in a phase locked loop. In this study, we experimentally investigate the effect in a microcomb with a repetition frequency of 300~GHz. We obtain a lowest fractional frequency instability at a quiet point of $1.5times 10^{-9}$ at 1 second, which is 44 times lower than free-running instability. Phase-locking of a microcomb to a stabilized fiber comb is demonstrated to evaluate performance in a feedback loop, where in-loop-limited relative fractional frequency instability between the microcomb and the fiber comb of $6.8 times 10^{-13}$ is obtained as an indicator of the stability limitation.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا