ترغب بنشر مسار تعليمي؟ اضغط هنا

Characterization of a large CdZnTe coplanar quad-grid semiconductor detector

79   0   0.0 ( 0 )
 نشر من قبل Robert Theinert
 تاريخ النشر 2015
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The COBRA collaboration aims to search for neutrinoless double beta-decay of $^{116}$Cd. A demonstrator setup with 64 CdZnTe semiconductor detectors, each with a volume of 1cm$^3$, is currently being operated at the LNGS underground laboratory in Italy. This paper reports on the characterization of a large (2 $times$ 2 $times$ 1.5)cm$^3$ CdZnTe detector with a new coplanar-grid design for applications in $gamma$-ray spectroscopy and low-background operation. Several studies of electric properties as well as of the spectrometric performance, like energy response and resolution, are conducted. Furthermore, measurements including investigating the operational stability and a possibility to identify multiple-scattered photons are presented.

قيم البحث

اقرأ أيضاً

A gaseous pixel readout module with four GridPix chips, called the quad, has been developed as a building block for a large time projection chamber readout plane. The quad module has dimensions 39.6 mm $times$ 28.38 mm and an active surface coverage of 68.9%. The GridPix chip consists of a Timepix3 chip with integrated amplification grid and have a high efficiency to detect single ionisation electrons, which enable to make a precise track position measurement. A quad module was installed in a small time projection chamber and measurements of 2.5 GeV electrons were performed at the ELSA accelerator in Bonn, where a silicon telescope was used to provide a reference track. The error on the track position measurement, both in the pixel plane and drift direction, is dominated by diffusion. The quad was designed to have minimum electrical field inhomogeneities and distortions, achieving systematics of better than 13 $mu$m in the pixel plane. The resolution of the setup is 41 $mu$m, where the total systematic error of the quad detector is 24 $mu$m.
The hyperspectral X-ray imaging has been long sought in various fields from material analysis to medical diagnosis. Here we propose a new semiconductor detector structure to realize energy-resolved imaging at potentially low cost. The working princip le is based on the strong energy-dependent absorption of X-ray in solids. Namely, depending on the energy, X-ray photons experience dramatically different attenuation. An array or matrix of semiconductor cells is to map the X-ray intensity along its trajectory. The X-ray spectrum could be extracted from a Laplace like transform or even a supervised machine learning. We demonstrated an energy-resolved X-ray detection with a regular silicon camera.
DTAS is a segmented total absorption {gamma}-ray spectrometer developed for the DESPEC experiment at FAIR. It is composed of up to eighteen NaI(Tl) crystals. In this work we study the performance of this detector with laboratory sources and also unde r real experimental conditions. We present a procedure to reconstruct offline the sum of the energy deposited in all the crystals of the spectrometer, which is complicated by the effect of NaI(Tl) light-yield non-proportionality. The use of a system to correct for time variations of the gain in individual detector modules, based on a light pulse generator, is demonstrated. We describe also an event-based method to evaluate the summing-pileup electronic distortion in segmented spectrometers. All of this allows a careful characterization of the detector with Monte Carlo simulations that is needed to calculate the response function for the analysis of total absorption {gamma}-ray spectroscopy data. Special attention was paid to the interaction of neutrons with the spectrometer, since they are a source of contamination in studies of b{eta}-delayed neutron emitting nuclei.
Silicon Drift Detectors, widely employed in high-resolution and high-rate X-ray applications, are considered here with interest also for electron detection. The accurate measurement of the tritium beta decay is the core of the TRISTAN (TRitium Invest igation on STerile to Active Neutrino mixing) project. This work presents the characterization of a single-pixel SDD detector with a mono-energetic electron beam obtained from a Scanning Electron Microscope. The suitability of the SDD to detect electrons, in the energy range spanning from few keV to tens of keV, is demonstrated. Experimental measurements reveal a strong effect of the detectors entrance window structure on the observed energy response. A detailed detector model is therefore necessary to reconstruct the spectrum of an unknown beta-decay source.
84 - R. Neilson , F. LePort , A. Pocar 2009
EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more than 800 LAAPDs for selective installation in the EXO-200 detector.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا