ترغب بنشر مسار تعليمي؟ اضغط هنا

Performance of a radiatively cooled system for quantum optomechanical experiments in space

72   0   0.0 ( 0 )
 نشر من قبل Rainer Kaltenbaek
 تاريخ النشر 2015
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The performance of a radiatively cooled instrument is investigated in the context of optomechanical quantum experiments, where the environment of a macroscopic particle in a quantum-superposition has to be cooled to less than 20,K in deep space. A heat-transfer analysis between the components of the instrument as well as a transfer-function analysis on thermal oscillations induced by the spacecraft interior and by dissipative sources is performed. The thermal behaviour of the instrument in an orbit around a Lagrangian point and in a highly elliptical Earth orbit is discussed. Finally, we investigate further possible design improvements aiming at lower temperatures of the environment of the macroscopic particle. These include a mirror-based design of the imaging system on the optical bench and the extension of the heat shields.

قيم البحث

اقرأ أيضاً

We consider an oscillating micromirror replacing one of the two fixed mirrors of a Mach-Zehnder interferometer. In this ideal optical set-up the quantum oscillator is subjected to the radiation pressure interaction of travelling light waves, no cavit y is involved. This configuration shows that squeezed light can be generated by pure scattering on a quantum system, without involving a cavity. The squeezing can be detected at the output ports of the interferometer either by direct detection or by measuring the spectrum of the difference current. We use the Hudson-Parthasarathy equation to model the global evolution. It can describe the scattering of photons and the resulting radiation pressure interaction on the quantum oscillator. It allows to consider also the interaction with a thermal bath. In this way we have a unitary dynamics giving the evolution of oscillator and fields. The Bose fields of quantum stochastic calculus and the related generalized Weyl operators allow to describe the whole optical circuit. By working in the Heisenberg picture, the quantum Langevin equations for position and momentum and the output fields arise, which are used to describe the monitoring in continuous time of the light at the output ports. In the case of strong laser and weak radiation pressure interaction highly non-classical light is produced, and this can be revealed either by direct detection (a negative Mandel Q-parameter is found), either by the intensity spectrum of the difference current of two photodetector; in the second case a nearly complete cancellation of the shot noise can be reached. In this last case it appears that the Mach-Zehnder configuration together with the detection of the difference current corresponds to an homodyne detection scheme, so that we can say that the apparatus is measuring the spectrum of squeezing.
We have designed, fabricated and operated a scalable system for applying independently programmable time-independent, and limited time-dependent flux biases to control superconducting devices in an integrated circuit. Here we report on the operation of a system designed to supply 64 flux biases to devices in a circuit designed to be a unit cell for a superconducting adiabatic quantum optimization system. The system requires six digital address lines, two power lines, and a handful of global analog lines.
A bubble chamber has been developed to be used as an active target system for low energy nuclear astrophysics experiments. Adopting ideas from dark matter detection with superheated liquids, a detector system compatible with gamma-ray beams has been developed. This detector alleviates some of the limitations encountered in standard measurements of the minute cross sections of interest to stellar environments. While the astrophysically relevant nuclear reaction processes at hydrostatic burning temperatures are dominated by radiative captures, in this experimental scheme we measure the time-reversed processes. Such photodisintegrations allow us to compute the radiative capture cross sections when transitions to excited states of the reaction products are negligible. Due to the transformation of phase space, the photodisintegration cross sections are up to two orders of magnitude higher. The main advantage of the new target-detector system is a density several orders of magnitude higher than conventional gas targets. Also, the detector is virtually insensitive to the gamma-ray beam itself, thus allowing us to detect only the products of the nuclear reaction of interest. The development and the operation as well as the advantages and disadvantages of the bubble chamber are discussed.
Realization of strong optomechanical coupling in the single-photon level is crucial to study quantum nonlinear effects and manipulate macroscopic object. Here, we propose an alternative method to towards this goal in a hybrid ensemble-optomechanical system. The sizable membrane-ensemble (ME) coupling mediated by the auxiliary mode of the cavity gives rise to polaritons with lower and higher frequencies. By tuning the ME coupling ($lambda_{rm en}$) approaching the critical coupling value ($lambda_c$), the eigen-energy of the low-frequency polariton gives rise to critical behavior (i.e., quantum phase transition) when the ensemble is within or beyond the low-excitation approximations. Using this critical behavior, the single-photon optomechanical coupling between the cavity and the low-frequency polariton can be greatly enhanced by almost three orders of magnitude with feasible parameters, while the coupling between the high-frequency polariton and the cavity is fully decouped. Our proposal provides a novel way to investigating Kerr effect and blockade in single-photon optomechanical systems.
Micro-optomechanical systems are central to a number of recent proposals for realizing quantum mechanical effects in relatively massive systems. Here we focus on a particular class of experiments which aim to demonstrate massive quantum superposition s, although the obtained results should be generalizable to similar experiments. We analyze in detail the effects of finite temperature on the interpretation of the experiment, and obtain a lower bound on the degree of non-classicality of the cantilever. Although it is possible to measure the quantum decoherence time when starting from finite temperature, an unambiguous demonstration of a quantum superposition requires the mechanical resonator to be in or near the ground state. This can be achieved by optical cooling of the fundamental mode, which also provides a method to measure the mean phonon number in that mode. We also calculate the rate of environmentally induced decoherence and estimate the timescale for gravitational collapse mechanisms as proposed by Penrose and Diosi. In view of recent experimental advances, practical considerations for the realization of the described experiment are discussed.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا