ترغب بنشر مسار تعليمي؟ اضغط هنا

A large-scale magnetic shield with 10^6 damping at mHz frequencies

169   0   0.0 ( 0 )
 نشر من قبل Tobias Lins
 تاريخ النشر 2015
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We present a magnetically shielded environment with a damping factor larger than one million at the mHz frequency regime and an extremely low field and gradient over an extended volume. This extraordinary shielding performance represents an improvement of the state of the art in damping the difficult regime of very low-frequency distortions by more than an order of magnitude. This technology enables a new generation of high precision measurements in fundamental physics and metrology, including searches for new physics far beyond the reach of accelerator-based experiments. We discuss the technical realization of the shield with its improvements in design.



قيم البحث

اقرأ أيضاً

The results of the first observations of Type IV bursts at frequencies 10-30 MHz are presented. These observations were carried out at radio telescopes UTR-2 (Kharkov, Ukraine) and URAN-2 (Poltava, Ukraine) during the period 2003-2006. Detection of T ype IV bursts in wide band from 10 to 30MHz with high sensitivity and time resolution allowed to study their properties in details. These bursts have fluxes 10-2000s.f.u. at maximum phase. Their durations are about 1-2 hours and even more. Some of Type IV bursts drift from high to low frequencies with drift rates about 10kHz/s. All observed Type IV bursts have fine structures in the form of sub-bursts with durations from 2s to 20s and frequency drift rates in a majority of 1-2MHz/s. In most cases, sub-bursts with negative drift rates were registered. Sometimes sub-bursts in absorption with durations 10-200s against Type IV burst background have been observed. The Type IV burst observed on July 22, 2004 had zebra structure, in which single zebra stripes had positive, negative and infinite drift rates.
79 - D. G. Matei 2017
We report on two ultrastable lasers each stabilized to independent silicon Fabry-Perot cavities operated at 124 K. The fractional frequency instability of each laser is completely determined by the fundamental thermal Brownian noise of the mirror coa tings with a flicker noise floor of $4 times 10^{-17}$ for integration times between 0.8 s and a few tens of seconds. We rigorously treat the notorious divergencies encountered with the associated flicker frequency noise and derive methods to relate this noise to observable and practically relevant linewidths and coherence times. The individual laser linewidth obtained from the phase noise spectrum or the direct beat note between the two lasers can be as small as 5 mHz at 194 THz. From the measured phase evolution between the two laser fields we derive usable phase coherence times for different applications of 11 s and 60 s.
We describe an autocollimating optical angle sensor with a dynamic range of 9 mrad and nrad/sqrt(Hz) sensitivity at frequencies from 5 mHz to 3 kHz. This work improves the standard multi-slit autocollimator design by adding two optical components, a reference mirror and a condensing lens. This autocollimator makes a differential measurement between a reference mirror and a target mirror, suppressing common-mode noise sources. The condensing lens reduces optical aberrations, increases intensity, and improves image quality. To further improve the stability of the device at low frequencies the body of the autocollimator is designed to reduce temperature variations and their effects. A new data processing technique was developed in order to suppress the effects of imperfections in the CCD.
99 - E. Wodey , D. Tell , E. M. Rasel 2019
We report on the design, construction, and characterization of a 10 m-long high-performance magnetic shield for Very Long Baseline Atom Interferometry (VLBAI). We achieve residual fields below 4 nT and longitudinal inhomogeneities below 2.5 nT/m over 8 m along the longitudinal direction. Our modular design can be extended to longer baselines without compromising the shielding performance. Such a setup constrains biases associated with magnetic field gradients to the sub-pm/$textrm{s}^2$ level in atomic matterwave accelerometry with rubidium atoms and paves the way towards tests of the universality of free fall with atomic test masses beyond the $10^{-13}$ level.
The magnetic characteristics of photomultiplier tube R5610A-01 are studied in this paper. The experimental data shows that the gain of R5610A-01 loses about 53% when the magnetic field is 3G along its +X axis. A cylinder of one-layer permalloy strip is able to reduce the effect of 3G magnetic field on the PMTs gain to less than 1%.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا