ترغب بنشر مسار تعليمي؟ اضغط هنا

Probing sub-eV particles with polarized Helium 3

28   0   0.0 ( 0 )
 نشر من قبل Mathieu Guigue Mr
 تاريخ النشر 2014
  مجال البحث فيزياء
والبحث باللغة English
 تأليف Mathieu Guigue




اسأل ChatGPT حول البحث

Proceeding of the Journ{e}es de Rencontre Jeunes Chercheurs 2013. Measuring the depolarization rate of a $^3$He hyperpolarized gas is a sensitive method to probe hypothetical short-range spin-dependent forces. A dedicated experiment is being set up at the Institute Laue Langevin in Grenoble to improve the sensitivity. The status of the experiment is detailed in this paper.

قيم البحث

اقرأ أيضاً

387 - Suyong Choi 2020
We propose a new experiment sensitive to the detection of millicharged particles produced at the $30$ GeV proton fixed-target collisions at J-PARC. The potential site for the experiment is B2 of the Neutrino Monitor building, $280$ m away from the ta rget. With $textrm{N}_textrm{POT}=10^{22}$, the experiment can provide sensitivity to particles with electric charge $3times10^{-4},e$ for mass less than $0.2$ $textrm{GeV}/textrm{c}^2$ and $1.5times10^{-3},e$ for mass less than $1.6$ $textrm{GeV}/textrm{c}^2$. This brings a substantial extension to the current constraints on the charge and the mass of such particles.
The European Research Council has recently funded HOLMES, a new experiment to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the decay of 163Ho. The calorimetric measurement eliminates sys tematic uncertainties arising from the use of external beta sources, as in experiments with beta spectrometers. This measurement was proposed in 1982 by A. De Rujula and M. Lusignoli, but only recently the detector technological progress allowed to design a sensitive experiment. HOLMES will deploy a large array of low temperature microcalorimeters with implanted 163Ho nuclei. The resulting mass sensitivity will be as low as 0.4 eV. HOLMES will be an important step forward in the direct neutrino mass measurement with a calorimetric approach as an alternative to spectrometry. It will also establish the potential of this approach to extend the sensitivity down to 0.1 eV. We outline here the project with its technical challenges and perspectives.
159 - P. A. M. Dolph 2011
The dynamics of the movement of gas is discussed for two-chambered polarized He-3 target cells of the sort that have been used successfully for many electron scattering experiments. A detailed analysis is presented showing that diffusion is a limitin g factor in target performance, particularly as these targets are run at increasingly high luminosities. Measurements are presented on a new prototype polarized He-3 target cell in which the movement of gas is due largely to convection instead of diffusion. NMR tagging techniques have been used to visualize the gas flow, showing velocities along a cylindrically-shaped target of between 5-80 cm/min. The new target design addresses one of the principle obstacles to running polarized He-3 targets at substantially higher luminosities while simultaneously providing new flexibility in target geometry.
We describe a modular apparatus for use in parity-violation measurements in epithermal neutron-nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos National Laboratory. This apparat us is designed to conduct high-precision measurements of the parity-odd transmission asymmetry of longitudinally polarized neutrons through targets containing nuclei with p-wave neutron-nucleus resonances in the 0.1-10 eV energy regime and to accommodate a future search for time reversal violation in polarized neutron transmission through polarized nuclear targets. The apparatus consists of an adjustable neutron and gamma collimation system, a (^3)He-$^{4}$He ion chamber neutron flux monitor, two identical cryostats for target cooling, an adiabatic eV-neutron spin flipper, a near-unit efficiency (^6)Li-(^{7})Li scintillation detector operated in current mode, a flexible CAEN data acquisition system, and a neutron spin filter based on spin-exchange optical pumping of $^{3}$He gas. We describe the features of the apparatus design devoted to the suppression of systematic errors in parity-odd asymmetry measurements. We describe the configuration of the apparatus used to conduct a precision measurement of parity violation at the 0.7 eV p-wave resonance in $^{139}$La which employs two identical $^{139}$La targets, one to polarize the beam on the p-wave resonance using the weak interaction and one to analyze the polarization.
72 - F. Aubin , M. Auger , E. Behnke 2008
The PICASSO collaboration observed for the first time a significant difference between the acoustic signals induced by neutrons and alpha particles in a detector based on superheated liquids. This new discovery offers the possibility of improved back ground suppression and could be especially useful for dark matter experiments. This new effect may be attributed to the formation of multiple bubbles on alpha tracks, compared to single nucleations created by neutron induced recoils.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا