ترغب بنشر مسار تعليمي؟ اضغط هنا

Large gain quantum-limited qubit measurement using a two-mode nonlinear cavity

179   0   0.0 ( 0 )
 نشر من قبل Saeed Khan
 تاريخ النشر 2014
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We provide a thorough theoretical analysis of qubit state measurement in a setup where a driven, parametrically-coupled cavity system is directly coupled to the qubit, with one of the cavities having a weak Kerr nonlinearity. Such a system could be readily realized using circuit QED architectures. We demonstrate that this setup is capable in the standard linear-response regime of both producing a highly amplified output signal while at the same time achieving near quantum-limited performance: the measurement backaction on the qubit is near the minimal amount required by the uncertainty principle. This setup thus represents a promising route for performing efficient large-gain qubit measurement that is completely on-chip, and that does not rely on the use of circulators or complex non-reciprocal amplifiers.

قيم البحث

اقرأ أيضاً

We theoretically study measurement induced-dephasing of a superconducting qubit in the circuit QED architecture and compare the results to those obtained experimentally by Schuster {it et al.}, [Phys. Rev. Lett. 94, 123602 (2005)]. Strong coupling of the qubit to the resonator leads to a significant ac-Stark shift of the qubit transition frequency. As a result, quantum fluctuations in the photon number populating the resonator cause dephasing of the qubit. We find good agreement between the predicted line shape of the qubit spectrum and the experimental results. Furthermore, in the strong dispersive limit, where the Stark shift per photon is large compared to the cavity decay rate and the qubit linewidth, we predict that the qubit spectrum will be split into multiple peaks, with each peak corresponding to a different number of photons in the cavity.
We demonstrate high-contrast state detection of a superconducting flux qubit. Detection is realized by probing the microwave transmission of a nonlinear resonator, based on a SQUID. Depending on the driving strength of the resonator, the detector can be operated in the monostable or the bistable mode. The bistable operation combines high-sensitivity with intrinsic latching. The measured contrast of Rabi oscillations is as high as 87 %; of the missing 13 %, only 3 % is unaccounted for. Experiments involving two consecutive detection pulses are consistent with preparation of the qubit state by the first measurement.
101 - S. Filipp , P. Maurer , P. J. Leek 2008
Quantum state tomography is an important tool in quantum information science for complete characterization of multi-qubit states and their correlations. Here we report a method to perform a joint simultaneous read-out of two superconducting qubits di spersively coupled to the same mode of a microwave transmission line resonator. The non-linear dependence of the resonator transmission on the qubit state dependent cavity frequency allows us to extract the full two-qubit correlations without the need for single shot read-out of individual qubits. We employ standard tomographic techniques to reconstruct the density matrix of two-qubit quantum states.
136 - P. J. Leek , S. Filipp , P. Maurer 2008
We demonstrate time resolved driving of two-photon blue sideband transitions between superconducting qubits and a transmission line resonator. Using the sidebands, we implement a pulse sequence that first entangles one qubit with the resonator, and s ubsequently distributes the entanglement between two qubits. We show generation of 75% fidelity Bell states by this method. The full density matrix of the two qubit system is extracted using joint measurement and quantum state tomography, and shows close agreement with numerical simulation. The scheme is potentially extendable to a scalable universal gate for quantum computation.
We study how the spontaneous relaxation of a qubit affects a continuous quantum non-demolition measurement of the initial state of the qubit. Given some noisy measurement record $Psi$, we seek an estimate of whether the qubit was initially in the gro und or excited state. We investigate four different measurement protocols, three of which use a linear filter (with different weighting factors) and a fourth which uses a full non-linear filter that gives the theoretically optimal estimate of the initial state of the qubit. We find that relaxation of the qubit at rate $1/T_1$ strongly influences the fidelity of any measurement protocol. To avoid errors due to this decay, the measurement must be completed in a time that decrease linearly with the desired fidelity while maintaining an adequate signal to noise ratio. We find that for the non-linear filter the predicted fidelity, as expected, is always better than the linear filters and that the fidelity is a monotone increasing function of the measurement time. For example, to achieve a fidelity of 90%, the box car linear filter requires a signal to noise ratio of $sim 30$ in a time $T_1$ whereas the non-linear filter only requires a signal to noise ratio of $sim 18$.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا