ترغب بنشر مسار تعليمي؟ اضغط هنا

Emittance Growth by Beam-Gas Scattering in Single Pass Accelerator

232   0   0.0 ( 0 )
 نشر من قبل Frederic Le Pimpec
 تاريخ النشر 2014
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

In order to ensure proper SASE lasing of a fourth Generation light source, one of the goal is to produce an electron beam of small emittance and to conserve it until its used in the machine undulator. One of the non recoverable emittance increase is the collision of the electron beam during its transport with the residual gas. Based on previous work by others, we have derived a useful expression of emittance increase for electrons of any energy and cross check its validity for energies above 100 MeV with an analytical formula.

قيم البحث

اقرأ أيضاً

76 - L. Groening , M. Maier , C. Xiao 2014
The performance of accelerators profits from phase space tailoring by coupling of planes. The previously applied techniques swap the emittances among the three planes but the set of available emittances is fixed. In contrast to these emittance exchan ge scenarios the emittance transfer scenario presented here allows for arbitrarily changing the set of emittances as long as the product of the emittances is preserved. This letter is on the first experimental demonstration of transverse emittance transfer along an ion beam line. The amount of transfer is chosen by setting just one single magnetic field value. The envelope-functions (beta) and -slopes (alpha) of the finally uncorrelated and re-partitioned beam at the exit of the transfer line do not depend on the amount of transfer.
85 - Ihar Lobach 2020
Generally, turn-to-turn power fluctuations of incoherent spontaneous synchrotron radiation in a storage ring depend on the 6D phase-space distribution of the electron bunch. In some cases, if only one parameter of the distribution is unknown, this pa rameter can be determined from the measured magnitude of these power fluctuations. In this Letter, we report an absolute measurement (no free parameters or calibration) of a small vertical emittance (5--15 nm rms) of a flat beam by this method, under conditions, when it is unresolvable by a conventional synchrotron light beam size monitor.
110 - R. Yang , A. Aryshev , P. Bambade 2021
Beam halo is one of the crucial issues limiting the machine performance and causing radioactivation in high-intensity accelerators. A clear picture of beam-halo formation is of great importance for successful suppression of the undesired beam loss. W e present numerical and experimental studies of transverse and longitudinal halos in the KEK Accelerator Test Facility. The fair accordance between predictions and observations in various conditions indicates that the Touschek scattering is the dominant mechanism forming the horizontal and momentum halos.
189 - X. L. Xu 2014
Ionization injection triggered by short wavelength laser pulses inside a nonlinear wakefield driven by a longer wavelength laser is examined via multi-dimensional particle-in-cell simulations. We find that very bright electron beams can be generated through this two-color scheme in either collinear propagating or transverse colliding geometry. For a fixed laser intensity $I$, lasers with longer/shorter wavelength $lambda$ have larger/smaller ponderomotive potential ($propto I lambda^2$). The two color scheme utilizes this property to separate the injection process from the wakefield excitation process. Very strong wakes can be generated at relatively low laser intensities by using a longer wavelength laser driver (e.g. a $10 micrometer$ CO$_2$ laser) due to its very large ponderomotive potential. On the other hand, short wavelength laser can produce electrons with very small residual momenta ($p_perpsim a_0sim sqrt{I}lambda$) inside the wake, leading to electron beams with very small normalized emittances (tens of $ anometer$). Using particle-in-cell simulations we show that a $sim10 femtosecond$ electron beam with $sim4 picocoulomb$ of charge and a normalized emittance of $sim 50 anometer$ can be generated by combining a 10 $micrometer $ driving laser with a 400 $ anometer$ injection laser, which is an improvement of more than one order of magnitude compared to the typical results obtained when a single wavelength laser used for both the wake formation and ionization injection.
The wire scanners are used for a measurement of the very small beam size and the emittance in Accelerator Test Facility (ATF). They are installed in the extraction beam line of ATF damping ring. The extracted beam emittance are ex=1.3x10-9 m.rad, ey= 1.7x10-11 m.rad with 2x109 electrons/bunch intensity and 1.3GeV energy. The wire scanners scan the beam by a tungsten wire with beam repetition 0.78Hz. The scanning speed is, however, very slow(~500um/sec). Since the extracted beam is quite stable by using the double kicker system, precision of the size measurement is less than 2um for 50 - 150um horizontal beam size and 0.3um for 8 - 16um vertical beam size. The detail of the system and the performance are described.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا