ترغب بنشر مسار تعليمي؟ اضغط هنا

Limits on light WIMPs with a germanium detector at 177 eVee threshold at the China Jinping Underground Laboratory

486   0   0.0 ( 0 )
 نشر من قبل Qian Yue
 تاريخ النشر 2014
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The China Dark Matter Experiment reports results on light WIMP dark matter searches at the China Jinping Underground Laboratory with a germanium detector array with a total mass of 20 g. The physics threshold achieved is 177 eVee (ee represents electron equivalent energy) at 50% signal efficiency. With 0.784 kg-days of data, exclusion region on spin-independent coupling with the nucleon is derived, improving over our earlier bounds at WIMP mass less than 4.6 GeV.



قيم البحث

اقرأ أيضاً

78 - L.T. Yang , H.B. Li , Q. Yue 2017
We report results of a search for light weakly interacting massive particle (WIMP) dark matter from the CDEX-1 experiment at the China Jinping Underground Laboratory (CJPL). Constraints on WIMP-nucleon spin-independent (SI) and spin-dependent (SD) co uplings are derived with a physics threshold of 160 eVee, from an exposure of 737.1 kg-days. The SI and SD limits extend the lower reach of light WIMPs to 2 GeV and improve over our earlier bounds at WIMP mass less than 6 GeV.
99 - L. T. Yang , H. B. Li , Q. Yue 2019
We present results on light weakly interacting massive particle (WIMP) searches with annual modulation (AM) analysis on data from a 1-kg mass $p$-type point-contact germanium detector of the CDEX-1B experiment at the China Jinping Underground Laborat ory. Datasets with a total live time of 3.2 yr within a 4.2 yr span are analyzed with analysis threshold of 250 eVee. Limits on WIMP-nucleus (${chi}$-$N$) spin-independent cross sections as function of WIMP mass ($m_{chi}$) at 90% confidence level (C.L.) are derived using the dark matter halo model. Within the context of the standard halo model, the 90% C.L. allowed regions implied by the DAMA/LIBRA and CoGeNT AM-based analysis are excluded at $>$99.99% and 98% C.L., respectively. These results correspond to the best sensitivity at $m_{chi}$$<$6$~{rm GeV}/c^2$ among WIMP AM measurements to date.
205 - W. Zhao , Q. Yue , K.J. Kang 2013
The China Dark matter Experiment collaboration reports the first experimental limit on WIMP dark matter from 14.6 kg-day of data taken with a 994 g p-type point-contact germanium detector at the China Jinping underground Laboratory where the rock ove rburden is more than 2400 m. The energy threshold achieved was 400 eVee. According to the 14.6 kg-day live data, we placed the limit of N= 1.75 * 10^{-40} cm^{2} at 90% confidence level on the spin-independent cross-section at WIMP mass of 7 GeV before differentiating bulk signals from the surface backgrounds.
431 - Q. Yue , W. Zhao , K.J. Kang 2014
We report results of a search for light Dark Matter WIMPs with CDEX-1 experiment at the China Jinping Underground Laboratory, based on 53.9 kg-days of data from a p-type point-contact germanium detector enclosed by a NaI(Tl) crystal scintillator as a nti-Compton detector. The event rate and spectrum above the analysis threshold of 475 eVee are consistent with the understood background model. Part of the allowed regions for WIMP-nucleus coherent elastic scattering at WIMP mass of 6-20 GeV are probed and excluded. Independent of interaction channels, this result contradicts the interpretation that the anomalous excesses of the CoGeNT experiment are induced by Dark Matter, since identical detector techniques are used in both experiments.
87 - Z. She , L. P. Jia , Q. Yue 2019
We report constraints on the dark photon effective kinetic mixing parameter (${kappa}$) with data taken from two ${p}$-type point-contact germanium detectors of the CDEX-10 experiment at the China Jinping Underground Laboratory. The 90% confidence le vel upper limits on ${kappa}$ of solar dark photon from 205.4 kg-day exposure are derived, probing new parameter space with masses (${m_V}$) from 10 to 300 eV/${c^2}$ in direct detection experiments. Considering dark photon as the cosmological dark matter, limits at 90% confidence level with ${m_V}$ from 0.1 to 4.0 keV/${c^2}$ are set from 449.6 kg-day data, with a minimum of ${rm{kappa=1.3 times 10^{-15}}}$ at ${rm{m_V=200 eV/c^2}}$.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا