ترغب بنشر مسار تعليمي؟ اضغط هنا

Suppression of Fiber Modal Noise Induced Radial Velocity Errors for Bright Emission-Line Calibration Sources

69   0   0.0 ( 0 )
 نشر من قبل Suvrath Mahadevan
 تاريخ النشر 2014
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Modal noise in optical fibers imposes limits on the signal to noise and velocity precision achievable with the next generation of astronomical spectrographs. This is an increasingly pressing problem for precision radial velocity (RV) spectrographs in the near-infrared (NIR) and optical that require both high stability of the observed line profiles and high signal to noise. Many of these spectrographs plan to use highly coherent emission line calibration sources like laser frequency combs and Fabry-Perot etalons to achieve precision sufficient to detect terrestrial mass planets. These high precision calibration sources often use single mode fibers or highly coherent sources. Coupling light from single mode fibers to multi-mode fibers leads to only a very low number of modes being excited, thereby exacerbating the modal noise measured by the spectrograph. We present a commercial off-the-shelf (COTS) solution that significantly mitigates modal noise at all optical and NIR wavelengths, and which can be applied to spectrograph calibration systems. Our solution uses an integrating sphere in conjunction with a diffuser that is moved rapidly using electrostrictive polymers, and is generally superior to most tested forms of mechanical fiber agitation. We demonstrate a high level of modal noise reduction with a narrow bandwidth 1550 nm laser. Our relatively inexpensive solution immediately enables spectrographs to take advantage of the innate precision of bright state-of-the art calibration sources by removing a major source of systematic noise.

قيم البحث

اقرأ أيضاً

Modal noise in fibers has been shown to limit the signal-to-noise ratio achievable in fiber-coupled, high-resolution spectrographs if it is not mitigated via modal scrambling techniques. Modal noise become significantly more important as the waveleng th increases and presents a risk to the new generation of near-infrared precision radial spectrographs under construction or being proposed to search for planets around cool M-dwarf stars, which emit most of their light in the NIR. We present experimental results of tests at Penn State University characterizing modal noise in the far visible out to 1.5 microns and the degree of modal scrambling we obtained using mechanical scramblers. These efforts are part of a risk mitigation effort for the Habitable Zone Planet Finder spectrograph currently under development at Penn State University.
248 - F. Bouchy , R.F. Diaz , G. Hebrard 2012
High-precision spectrographs play a key role in exoplanet searches and Doppler asteroseismology using the radial velocity technique. The 1 m/s level of precision requires very high stability and uniformity of the illumination of the spectrograph. In fiber-fed spectrographs such as SOPHIE, the fiber-link scrambling properties are one of the main conditions for high precision. To significantly improve the radial velocity precision of the SOPHIE spectrograph, which was limited to 5-6 m/s, we implemented a piece of octagonal-section fiber in the fiber link. We present here the scientific validation of the upgrade of this instrument, demonstrating a real improvement. The upgraded instrument, renamed SOPHIE+, reaches radial velocity precision in the range of 1-2 m/s. It is now fully efficient for the detection of low-mass exoplanets down to 5-10 Earth mass and for the identification of acoustic modes down to a few tens of cm/s.
The MINiature Exoplanet Radial Velocity Array (MINERVA) is a dedicated observatory of four 0.7m robotic telescopes fiber-fed to a KiwiSpec spectrograph. The MINERVA mission is to discover super-Earths in the habitable zones of nearby stars. This can be accomplished with MINERVAs unique combination of high precision and high cadence over long time periods. In this work, we detail changes to the MINERVA facility that have occurred since our previous paper. We then describe MINERVAs robotic control software, the process by which we perform 1D spectral extraction, and our forward modeling Doppler pipeline. In the process of improving our forward modeling procedure, we found that our spectrographs intrinsic instrumental profile is stable for at least nine months. Because of that, we characterized our instrumental profile with a time-independent, cubic spline function based on the profile in the cross dispersion direction, with which we achieved a radial velocity precision similar to using a conventional sum-of-Gaussians instrumental profile: 1.8 m s$^{-1}$ over 1.5 months on the RV standard star HD 122064. Therefore, we conclude that the instrumental profile need not be perfectly accurate as long as it is stable. In addition, we observed 51 Peg and our results are consistent with the literature, confirming our spectrograph and Doppler pipeline are producing accurate and precise radial velocities.
The dispersed fixed-delay interferometer (DFDI) represents a new instrument concept for high-precision radial velocity (RV) surveys for extrasolar planets. A combination of Michelson interferometer and medium-resolution spectrograph, it has the poten tial for performing multi-object surveys, where most previous RV techniques have been limited to observing only one target at a time. Because of the large sample of extrasolar planets needed to better understand planetary formation, evolution, and prevalence, this new technique represents a logical next step in instrumentation for RV extrasolar planet searches, and has been proven with the single-object Exoplanet Tracker (ET) at Kitt Peak National Observatory, and the multi-object W. M. Keck/MARVELS Exoplanet Tracker at Apache Point Observatory. The development of the ET instruments has necessitated fleshing out a detailed understanding of the physical principles of the DFDI technique. Here we summarize the fundamental theoretical material needed to understand the technique and provide an overview of the physics underlying the instruments working. We also derive some useful analytical formulae that can be used to estimate the level of various sources of error generic to the technique, such as photon shot noise when using a fiducial reference spectrum, contamination by secondary spectra (e.g., crowded sources, spectroscopic binaries, or moonlight contamination), residual interferometer comb, and reference cross-talk error. Following this, we show that the use of a traditional gas absorption fiducial reference with a DFDI can incur significant systematic errors that must be taken into account at the precision levels required to detect extrasolar planets.
The fully marginalized likelihood, or Bayesian evidence, is of great importance in probabilistic data analysis, because it is involved in calculating the posterior probability of a model or re-weighting a mixture of models conditioned on data. It is, however, extremely challenging to compute. This paper presents a geometric-path Monte Carlo method, inspired by multi-canonical Monte Carlo to evaluate the fully marginalized likelihood. We show that the algorithm is very fast and easy to implement and produces a justified uncertainty estimate on the fully marginalized likelihood. The algorithm performs efficiently on a trial problem and multi-companion model fitting for radial velocity data. For the trial problem, the algorithm returns the correct fully marginalized likelihood, and the estimated uncertainty is also consistent with the standard deviation of results from multiple runs. We apply the algorithm to the problem of fitting radial velocity data from HIP 88048 ($ u$ Oph) and Gliese 581. We evaluate the fully marginalized likelihood of 1, 2, 3, and 4-companion models given data from HIP 88048 and various choices of prior distributions. We consider prior distributions with three different minimum radial velocity amplitude $K_{mathrm{min}}$. Under all three priors, the 2-companion model has the largest marginalized likelihood, but the detailed values depend strongly on $K_{mathrm{min}}$. We also evaluate the fully marginalized likelihood of 3, 4, 5, and 6-planet model given data from Gliese 581 and find that the fully marginalized likelihood of the 5-planet model is too close to that of the 6-planet model for us to confidently decide between them.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا