ترغب بنشر مسار تعليمي؟ اضغط هنا

Comparing Finesse simulations, analytical solutions and OSCAR simulations of Fabry-Perot alignment signals

178   0   0.0 ( 0 )
 نشر من قبل Andreas Freise
 تاريخ النشر 2014
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

This document records the results of a comparison of the interferometer simulation Finesse against an analytic (MATLAB based) calculation of the alignment sensing signals of a Fabry Perot cavity. This task was started during the commissioning workshop at the LIGO Livingston site between the 28.1. and 1.02 2013 with the aim of creating a reference example for validating numerical simulation tools. The FFT based simulation OSCAR joined the battle later.

قيم البحث

اقرأ أيضاً

A comparison of analytic calculations and FINESSE simulations of interferometer responses to gravitational wave strain. The response to a gravitational wave is gradually built up from the effect of modulating a space by a gravitational wave to Sagnac and Michelson interferometers with and without arm cavities. This document details the steps necessary to perform such simulations in FINESSE and explicitly derives the interferometer response equations.
We demonstrate the optical coupling of two cavities without light transmission through a substrate. Compared to a conventional coupling component, that is a partially transmissive mirror, an all-reflective coupler avoids light absorption in the subst rate and therefore associated thermal problems, and even allows the use of opaque materials with possibly favourable mechanical and thermal properties. Recently, the all-reflective coupling of two cavities with a low-efficiency 3-port diffraction grating was theoretically investigated. Such a grating has an additional (a third) port. However, it was shown that the additional port does not necessarily decrease the bandwidth of the coupled cavities. Such an all-reflective scheme for cavity coupling is of interest in the field of gravitational wave detection. In such detectors light that is resonantly enhanced inside the so-called power-recycling cavity is coupled to (kilometre-scale) Fabry-Perot resonators representing the arms of a Michelson interferometer. In order to achieve a high sensitivity over a broad spectrum, the Fabry-Perot resonators need to have a high bandwidth for a given (high) power build-up. We realized such an all-reflective coupling in a table-top experiment. Our findings are in full agreement with the theoretical model incorporating the characteristics of the 3-port grating used, and therefore encourage the application of all-reflective cavity couplers in future gravitational wave detectors.
We measured the far-field emission patterns in three dimensions of flat organic dye microlasers using a solid angle scanner. Polymer-based microcavities of ribbon shape (i.e., Fabry-Perot type) were investigated. Out of plane emission from the caviti es was observed, with significant differences for the two cases of resonators either fully supported by the substrate or sustained by a pedestal. In both cases, the emission diagrams are accounted for by a model combining diffraction at the cavity edges and reflections from the substrate.
We propose a novel photonic structure composed of metal nanolayer, Bragg mirror and metal nanolayer. The structure supports resonances that are transitional between Fabry-Perot and Tamm modes. When the dielectric contrast of the DBR is removed these modes are a pair of conventional Fabry-Perot resonances. They spectrally merge into a Tamm mode at high contrast. Such behavior differs from the results for structures supporting Tamm modes reported earlier. The optical properties of the structure in the frequency range of the DBR stop band, including highly beneficial 50% transmittivity through thick structures, are determined by the introduced in the paper hybrid resonances. The results can find a wide range of photonic applications.
Light scattering by a two-dimensional photonic crystal slab (PCS) can result in dramatic interference effects associated with Fano resonances. Such devices offer appealing alternatives to distributed Bragg reflectors or filters for various applicatio ns such as optical wavelength and polarization filters, reflectors, semiconductor lasers, photodetectors, bio-sensors, or non-linear optical components. Suspended PCSs also find natural applications in the field of optomechanics, where the mechanical modes of a suspended slab interact via radiation pressure with the optical field of a high finesse cavity. The reflectivity and transmission properties of a defect-free suspended PCS around normal incidence can be used to couple out-of-plane mechanical modes to an optical field by integrating it in a free space cavity. Here, we demonstrate the successful implementation of a PCS reflector on a high-tensile stress Si$_3$N$_4$ nanomembrane. We illustrate the physical process underlying the high reflectivity by measuring the photonic crystal band diagram. Moreover, we introduce a clear theoretical description of the membrane scattering properties in the presence of optical losses. By embedding the PCS inside a high-finesse cavity, we fully characterize its optical properties. The spectrally, angular, and polarization resolved measurements demonstrate the wide tunability of the membranes reflectivity, from nearly 0 to 99.9470~$pm$ 0.0025 %, and show that material absorption is not the main source of optical loss. Moreover, the cavity storage time demonstrated in this work exceeds the mechanical period of low-order mechanical drum modes. This so-called resolved sideband condition is a prerequisite to achieve quantum control of the mechanical resonator with light.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا