ترغب بنشر مسار تعليمي؟ اضغط هنا

Enzymatic AND Logic Gate with Sigmoid Response Induced by Photochemically Controlled Oxidation of the Output

140   0   0.0 ( 0 )
 نشر من قبل Vladimir Privman
 تاريخ النشر 2013
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We report a study of a system which involves an enzymatic cascade realizing an AND logic gate, with an added photochemical processing of the output allowing to make the gates response sigmoid in both inputs. New functional forms are developed for quantifying the kinetics of such systems, specifically designed to model their response in terms of signal and information processing. These theoretical expressions are tested for the studied system, which also allows us to consider aspects of biochemical information processing such as noise transmission properties and control of timing of the chemical and physical steps.



قيم البحث

اقرأ أيضاً

We report the first systematic study of designed two-input biochemical systems as information processing gates with favorable noise-transmission properties accomplished by modifying the gates response from convex shape to sigmoid in both inputs. This is realized by an added chemical filter process which recycles some of the output back into one of the inputs. We study a system involving the biocatalytic function of the enzyme horseradish peroxidase, functioning as an AND gate. We consider modularity properties, such as the use of three different input chromogens that, when oxidized yield signal-detection outputs for various ranges of the primary input, hydrogen peroxide. We also examine possible uses of different filter-effect chemicals (reducing agents) to induce the sigmoid-response. A modeling approach is developed and applied to our data, allowing us to describe the enzymatic kinetics in the framework of a formulation suitable for evaluating the noise-handling properties of the studied systems as logic gates for information processing steps.
Computing based on biochemical processes is a newest rapidly developing field of unconventional information and signal processing. In this paper we present results of our research in the field of biochemical computing and summarize the obtained numer ical and experimental data for implementations of the standard two-input OR and AND gates with double-sigmoid shape of the output signal. This form of response was obtained as a function of the two inputs in each of the realized biochemical systems. The enzymatic gate processes in the first system were activated with two chemical inputs and resulted in optically detected chromogen oxidation, which happens when either one or both of the inputs are present. In this case, the biochemical system is functioning as the OR gate. We demonstrate that the addition of a filtering biocatalytic process leads to a considerable reduction of the noise transmission factor and the resulting gate response has sigmoid shape in both inputs. The second system was developed for functioning as an AND gate, where the output signal was activated only by a simultaneous action of two enzymatic biomarkers. This response can be used as an indicator of liver damage, but only if both of these of the inputs are present at their elevated, pathophysiological values of concentrations. A kinetic numerical model was developed and used to estimate the range of parameters for which the experimentally realized logic gate is close to optimal. We also analyzed the system to evaluate its noise-handling properties.
Biomolecular logic systems processing biochemical input signals and producing digital outputs in the form of YES/NO were developed for analysis of physiological conditions characteristic of liver injury, soft tissue injury and abdominal trauma. Injur y biomarkers were used as input signals for activating the logic systems. Their normal physiological concentrations were defined as logic-0 level, while their pathologically elevated concentrations were defined as logic-1 values. Since the input concentrations applied as logic 0 and 1 values were not sufficiently different, the output signals being at low and high values (0, 1 outputs) were separated with a short gap making their discrimination difficult. Coupled enzymatic reactions functioning as a biomolecular signal processing system with a built-in filter property were developed. The filter process involves a partial back-conversion of the optical-output-signal-yielding product, but only at its low concentrations, thus allowing the proper discrimination between 0 and 1 output values.
The first realization of a biomolecular OR gate function with double-sigmoid response (sigmoid in both inputs) is reported. Two chemical inputs activate the enzymatic gate processes resulting in the output signal: chromogen oxidation, which occurs wh en either one of the inputs or both are present (corresponding to the OR binary function), and can be optically detected. High-quality gate functioning in handling of sources of noise is enabled by filtering involving pH control with an added buffer. The resulting gate response is sigmoid in both inputs when proper system parameters are chosen, and the gate properties are theoretically analyzed within a model devised to evaluate its noise-handling properties.
We report the first realization of a biomolecular AND gate function with double-sigmoid response (sigmoid in both inputs). Two enzyme biomarker inputs activate the gate output signal which can then be used as indicating liver injury, but only when bo th of these inputs have elevated pathophysiological concentrations, effectively corresponding to logic-1 of the binary gate functioning. At lower, normal physiological concentrations, defined as logic-0 inputs, the liver-injury output levels are not obtained. High-quality gate functioning in handling of various sources of noise, on time scales of relevance to potential applications is enabled by utilizing filtering effected by a simple added biocatalytic process. The resulting gate response is sigmoid in both inputs when proper system parameters are chosen, and the gate properties are theoretically analyzed within a model devised to evaluate its noise-handling properties.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا