ترغب بنشر مسار تعليمي؟ اضغط هنا

Development of a camera casing suited for cryogenic and vacuum applications

150   0   0.0 ( 0 )
 نشر من قبل S\\'ebastien Claude Delaquis
 تاريخ النشر 2013
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We report on the design, construction, and operation of a PID temperature controlled and vacuum tight camera casing. The camera casing contains a commercial digital camera and a lighting system. The design of the camera casing and its components are discussed in detail. Pictures taken by this cryo-camera while immersed in argon vapour and liquid nitrogen are presented. The cryo-camera can provide a live view inside cryogenic set-ups and allows to record video.

قيم البحث

اقرأ أيضاً

The Argonne MCP-based photo detector is an offshoot of the Large Area Pico-second Photo Detector (LAPPD) project, wherein 6 cm x 6 cm sized detectors are made at Argonne National Laboratory. We have successfully built and tested our first detectors f or pico-second timing and few mm spatial resolution. We discuss our efforts to customize these detectors to operate in a cryogenic environment. Initial plans aim to operate in liquid argon. We are also exploring ways to mitigate wave length shifting requirements and also developing bare-MCP photodetectors to operate in a gaseous cryogenic environment.
In this paper we describe the technology of building a vacuum-tight high voltage feedthrough which is able to operate at voltages up to 30 kV. The feedthrough has a coaxial structure with a grounded sheath which makes it capable to lead high voltage potentials into cryogenic liquids, without risk of surface discharges in the gas phase above the liquid level. The feedthrough is designed to be used in ionization detectors, based on liquefied noble gases, such as Argon or Xenon.
As part of an experiment to measure the spectrum of photons emitted in beta-decay of the free neutron, we developed and operated a detector consisting of 12 bismuth germanate (BGO) crystals coupled to avalanche photodiodes (APDs). The detector was op erated near liquid nitrogen temperature in the bore of a superconducting magnet and registered photons with energies from 5 keV to 1000 keV. To enlarge the detection range, we also directly detected soft X-rays with energies between 0.2 keV and 20 keV with three large area APDs. The construction and operation of the detector is presented, as well as information on operation of APDs at cryogenic temperatures.
We have designed and characterized a cryogenic amplifier for use in $^3$He NMR spectrometry. The amplifier, with a power consumption of $sim 2.5$ mW, works at temperatures down to 4~K. It has a hi-impedance input for measuring a signal from NMR reson ant circuit, and a 50 $mathrm{Omega}$ differential input which can be used for pick-up compensation and gain calibration. At 4.2 K, the amplifier has a voltage gain of 45, output resistance 146 $mathrm{Omega}$ and a 4.4 MHz bandwidth starting from DC. At 1 MHz, the voltage and current noise amount to 1.3 $mbox{nV}/sqrt{mbox{Hz}}$ and 12 $mbox{fA}/sqrt{mbox{Hz}}$, respectively, which yields an optimal source impedance of $sim 100$ k$mathrm{Omega}$.
Micro-channel plate (MCP)-based photodetectors are capable of picosecond level time resolution and sub-mm level position resolution, which makes them a perfect candidate for the next generation large area photodetectors. The large-area picosecond pho todetector (LAPPD) collaboration is developing new techniques for making large-area photodetectors based on new MCP fabrication and functionalization methods. A small single tube processing system (SmSTPS) was constructed at Argonne National Laboratory (ANL) for developing scalable, cost-effective, glass-body, 6 cm x 6 cm, picosecond photodetectors based on MCPs functionalized by Atomic Layer Deposition (ALD). Recently, a number of fully processed and hermitically sealed prototypes made of MCPs with 20 micron pores have been fabricated. This is a significant milestone for the LAPPD project. These prototypes were characterized with a pulsed laser test facility. Without optimization, the prototypes have shown excellent results: The time resolution is ~57 ps for single photoelectron mode and ~15 ps for multi-photoelectron mode; the best position resolution is < 0.8 mm for large pulses. In this paper, the tube processing system, the detector assembly, experimental setup, data analysis and the key performance will be presented.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا