We report on our on-going effort to measure the Boltzmann constant, kB, using the Doppler Broadening Technique. The main systematic effects affecting the measurement are discussed. A revised error budget is presented in which the global uncertainty on systematic effects is reduced to 2.3 ppm. This corresponds to a reduction of more than one order of magnitude compared to our previous Boltzmann constant measurement. Means to reach a determination of kB at the part per million accuracy level are outlined.

قيم البحث

اقرأ أيضاً

In this paper, we present significant progress performed on an experiment dedicated to the determination of the Boltzmann constant, k, by accurately measuring the Doppler absorption profile of a line in a gas of ammonia at thermal equilibrium. This o ptical method based on the first principles of statistical mechanics is an alternative to the acoustical method which has led to the unique determination of k published by the CODATA with a relative accuracy of 1.7 ppm. We report on the first measurement of the Boltzmann constant by laser spectroscopy with a statistical uncertainty below 10 ppm, more specifically 6.4 ppm. This progress results from improvements in the detection method and in the statistical treatment of the data. In addition, we have recorded the hyperfine structure of the probed saQ(6,3) rovibrational line of ammonia by saturation spectroscopy and thus determine very precisely the induced 4.36 (2) ppm broadening of the absorption linewidth. We also show that, in our well chosen experimental conditions, saturation effects have a negligible impact on the linewidth. Finally, we draw the route to future developments for an absolute determination of with an accuracy of a few ppm.
We demonstrate a simple technique to measure the resonant frequency of the 398.9 nm 1S0 - 1P1 transition for the different Yb isotopes. The technique, that works by observing and aligning fluorescence spots, has enabled us to measure transition frequ encies and isotope shifts with an accuracy of 60 MHz. We provide wavelength measurements for the transition that differ from previously published work. Our technique also allows for the determination of Doppler shifted transition frequencies for photoionisation experiments when the atomic beam and laser beam are not perpendicular and furthermore allows us to determine the average velocity of the atoms along the direction of atomic beam.
A theoretical model of the influence of detection bandwidth properties on observed line shapes in laser absorption spectroscopy is described. The model predicts artificial frequency shifts, extra broadenings and line asymmetries which must be taken i nto account in order to obtain accurate central frequencies and other spectroscopic parameters. This reveals sources of systematic effects most probably underestimated so far potentially affecting spectroscopic measurements. This may impact many fields of research, from atmospheric and interstellar physics to precision spectroscopic measurements devoted to metrological applications, tests of quantum electrodynamics or other fundamental laws of nature. Our theoretical model is validated by linear absorption experiments performed on H2O and NH3 molecular lines recorded by precision laser spectroscopy in two distinct spectral regions, near- and mid-infrared. Possible means of recovering original line shape parameters or experimental conditions under which the detection bandwidth has a negligible impact, given a targeted accuracy, are proposed. Particular emphasis is put on the detection bandwidth adjustments required to use such high-quality molecular spectra for a spectroscopic determination of the Boltzmann constant at the 1 ppm level of accuracy.
89 - Beno^it Darquie 2015
Accurate molecular spectroscopy in the mid-infrared region allows precision measurements of fundamental constants. For instance, measuring the linewidth of an isolated Doppler-broadened absorption line of ammonia around 10 $mu$m enables a determinati on of the Boltzmann constant k B. We report on our latest measurements. By fitting this lineshape to several models which include Dicke narrowing or speed-dependent collisional effects, we find that a determination of k B with an uncertainty of a few ppm is reachable. This is comparable to the best current uncertainty obtained using acoustic methods and would make a significant contribution to any new value of k B determined by the CODATA. Furthermore, having multiple independent measurements at these accuracies opens the possibility of defining the kelvin by fixing k B, an exciting prospect considering the upcoming redefinition of the International System of Units.
We investigate the temporal dynamics of Doppler cooling of an initially hot single trapped atom in the weak binding regime using a semiclassical approach. We develop an analytical model for the simplest case of a single vibrational mode for a harmoni c trap, and show how this model allows us to estimate the initial energy of the trapped particle by observing the fluorescence rate during the cooling process. The experimental implementation of this temperature measurement provides a way to measure atom heating rates by observing the temperature rise in the absence of cooling. This method is technically relatively simple compared to conventional sideband detection methods, and the two methods are in reasonable agreement. We also discuss the effects of RF micromotion, relevant for a trapped atomic ion, and the effect of coupling between the vibrational modes on the cooling dynamics.