ترغب بنشر مسار تعليمي؟ اضغط هنا

Scanning nano-SQUID with single electron spin sensitivity

114   0   0.0 ( 0 )
 نشر من قبل Denis Vasyukov
 تاريخ النشر 2013
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

One of the critical milestones in the intensive pursuit of quantitative nanoscale magnetic imaging tools is achieving the level of sensitivity required for detecting the field generated by the spin magnetic moment {mu}B of a single electron. Superconducting quantum interference devices (SQUIDs), which were traditionally the most sensitive magnetometers, could not hitherto reach this goal because of their relatively large effective size (of the order of 1 {mu}m). Here we report self-aligned fabrication of nano-SQUIDs with diameters as small as 46 nm and with an extremely low flux noise of 50 n{Phi}0/Hz^1/2, representing almost two orders of magnitude improvement in spin sensitivity, down to 0.38 {mu}B/Hz^1/2. In addition, the devices operate over a wide range of magnetic fields with 0.6 {mu}B/Hz^1/2 sensitivity even at 1 T. We demonstrate magnetic imaging of vortices in type II superconductor that are 120 nm apart and scanning measurements of AC magnetic fields down to 50 nT. The unique geometry of these nano-SQUIDs that reside on the apex of a sharp tip allows approaching the sample to within a few nm, which paves the way to a new class of single-spin resolved scanning probe microscopy.



قيم البحث

اقرأ أيضاً

Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the size of th e field sensitive area and the spacing between this area and the sample surface. In this paper we describe scanning SQUID susceptometers that achieve sub-micron spatial resolution while retaining a white noise floor flux sensitivity of $approx 2muPhi_0/Hz^{1/2}$. This high spatial resolution is accomplished by deep sub-micron feature sizes, well shielded pickup loops fabricated using a planarized process, and a deep etch step that minimizes the spacing between the sample surface and the SQUID pickup loop. We describe the design, modeling, fabrication, and testing of these sensors. Although sub-micron spatial resolution has been achieved previously in scanning SQUID sensors, our sensors not only achieve high spatial resolution, but also have integrated modulation coils for flux feedback, integrated field coils for susceptibility measurements, and batch processing. They are therefore a generally applicable tool for imaging sample magnetization, currents, and susceptibilities with higher spatial resolution than previous susceptometers.
Scanning Superconducting QUantum Interference Device (SQUID) microscopy is a powerful tool for imaging local magnetic properties of materials and devices, but it requires a low-vibration cryogenic environment, traditionally achieved by thermal contac t with a bath of liquid helium or the mixing chamber of a wet dilution refrigerator. We mount a SQUID microscope on the 3 K plate of a Bluefors cryocooler and characterize its vibration spectrum by measuring SQUID noise in a region of sharp flux gradient. By implementing passive vibration isolation, we reduce relative sensor-sample vibrations to 20 nm in-plane and 15 nm out-of-plane. A variable-temperature sample stage that is thermally isolated from the SQUID sensor enables measurement at sample temperatures from 2.8 K to 110 K. We demonstrate these advances by imaging inhomogeneous diamagnetic susceptibility and vortex pinning in optimally-doped YBCO above 90 K.
Scanning SQUID susceptometry images the local magnetization and susceptibility of a sample. By accurately modeling the SQUID signal we can determine the physical properties such as the penetration depth and permeability of superconducting samples. We calculate the scanning SQUID susceptometry signal for a superconducting slab of arbitrary thickness with isotropic London penetration depth, on a non-superconducting substrate, where both slab and substrate can have a paramagnetic response that is linear in the applied field. We derive analytical approximations to our general expression in a number of limits. Using our results, we fit experimental susceptibility data as a function of the sample-sensor spacing for three samples: 1) delta-doped SrTiO3, which has a predominantly diamagnetic response, 2) a thin film of LaNiO3, which has a predominantly paramagnetic response, and 3) a two-dimensional electron layer (2-DEL) at a SrTiO3/AlAlO3 interface, which exhibits both types of response. These formulas will allow the determination of the concentrations of paramagnetic spins and superconducting carriers from fits to scanning SQUID susceptibility measurements.
Scanning nanoscale superconducting quantum interference devices (nanoSQUIDs) are of growing interest for highly sensitive quantitative imaging of magnetic, spintronic, and transport properties of low-dimensional systems. Utilizing specifically design ed grooved quartz capillaries pulled into a sharp pipette, we have fabricated the smallest SQUID-on-tip (SOT) devices with effective diameters down to 39 nm. Integration of a resistive shunt in close proximity to the pipette apex combined with self-aligned deposition of In and Sn, have resulted in SOT with a flux noise of 42 n$Phi_0$Hz$^{-1/2}$, yielding a record low spin noise of 0.29 $mu_B$Hz$^{-1/2}$. In addition, the new SOTs function at sub-Kelvin temperatures and in high magnetic fields of over 2.5 T. Integrating the SOTs into a scanning probe microscope allowed us to image the stray field of a single Fe$_3$O$_4$ nanocube at 300 mK. Our results show that the easy magnetization axis direction undergoes a transition from the (111) direction at room temperature to an in-plane orientation, which could be attributed to the Verwey phase transition in Fe$_3$O$_4$.
The diamagnetic susceptibility of a superconductor is directly related to its superfluid density. Mutual inductance is a highly sensitive method for characterizing thin films; however, in traditional mutual inductance measurements, the measured respo nse is a non-trivial average over the area of the mutual inductance coils, which are typically of millimeter size. Here we image localized, isolated features in the diamagnetic susceptibility of {delta}-doped SrTiO3, the 2-DES at the interface between LaAlO3 and SrTiO3, and Nb superconducting thin film systems using scanning superconducting quantum interference device susceptometry, with spatial resolution as fine as 0.7 {mu}m. We show that these features can be modeled as locally suppressed superfluid density, with a single parameter that characterizes the strength of each feature. This method provides a systematic means of finding and quantifying submicron defects in two-dimensional superconductors.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا