ترغب بنشر مسار تعليمي؟ اضغط هنا

Lunar Imaging and Ionospheric Calibration for the Lunar Cherenkov Technique

129   0   0.0 ( 0 )
 نشر من قبل Rebecca McFadden
 تاريخ النشر 2013
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The Lunar Cherenkov technique is a promising method for UHE neutrino and cosmic ray detection which aims to detect nanosecond radio pulses produced during particle interactions in the Lunar regolith. For low frequency experiments, such as NuMoon, the frequency dependent dispersive effect of the ionosphere is an important experimental concern as it reduces the pulse amplitude and subsequent chances of detection. We are continuing to investigate a new method to calibrate the dispersive effect of the ionosphere on lunar Cherenkov pulses via Faraday rotation measurements of the Moons polarised emission combined with geomagnetic field models. We also extend this work to include radio imaging of the Lunar surface, which provides information on the physical and chemical properties of the lunar surface that may affect experimental strategies for the lunar Cherenkov technique.



قيم البحث

اقرأ أيضاً

Lunar Cherenkov experiments aim to detect nanosecond pulses of Cherenkov emission produced during UHE cosmic ray or neutrino interactions in the lunar regolith. Pulses from these interactions are dispersed, and therefore reduced in amplitude, during propagation through the Earths ionosphere. Pulse dispersion must therefore be corrected to maximise the received signal to noise ratio and subsequent chances of detection. The pulse dispersion characteristic may also provide a powerful signature to determine the lunar origin of a pulse and discriminate against pulses of terrestrial radio frequency interference (RFI). This characteristic is parameterised by the instantaneous Total Electron Content (TEC) of the ionosphere and therefore an accurate knowledge of the ionospheric TEC provides an experimental advantage for the detection and identification of lunar Cherenkov pulses. We present a new method to calibrate the dispersive effect of the ionosphere on lunar Cherenkov pulses using lunar Faraday rotation measurements combined with geomagnetic field models.
The lunar Askaryan technique, which involves searching for Askaryan radio pulses from particle cascades in the outer layers of the Moon, is a method for using the lunar surface as an extremely large detector of ultra-high-energy particles. The high t ime resolution required to detect these pulses, which have a duration of around a nanosecond, puts this technique in a regime quite different from other forms of radio astronomy, with a unique set of associated technical challenges which have been addressed in a series of experiments by various groups. Implementing the methods and techniques developed by these groups for detecting lunar Askaryan pulses will be important for a future experiment with the Square Kilometre Array (SKA), which is expected to have sufficient sensitivity to allow the first positive detection using this technique. Key issues include correction for ionospheric dispersion, beamforming, efficient triggering, and the exclusion of spurious events from radio-frequency interference. We review the progress in each of these areas, and consider the further progress expected for future application with the SKA.
UHE particle detection using the lunar Cherenkov technique aims to detect nanosecond pulses of Cherenkov emission which are produced during UHE cosmic ray and neutrino interactions in the Moons regolith. These pulses will reach Earth-based telescopes dispersed, and therefore reduced in amplitude, due to their propagation through the Earths ionosphere. To maximise the received signal to noise ratio and subsequent chances of pulse detection, ionospheric dispersion must therefore be corrected, and since the high time resolution would require excessive data storage this correction must be made in real time. This requires an accurate knowledge of the dispersion characteristic which is parameterised by the instantaneous Total Electron Content (TEC) of the ionosphere. A new method to calibrate the dispersive effect of the ionosphere on lunar Cherenkov pulses has been developed for the LUNASKA lunar Cherenkov experiments. This method exploits radial symmetries in the distribution of the Moons polarised emission to make Faraday rotation measurements in the visibility domain of synthesis array data (i. e. instantaneously). Faraday rotation measurements are then combined with geomagnetic field models to estimate the ionospheric TEC. This method of ionospheric calibration is particularly attractive for the lunar Cherenkov technique as it may be used in real time to estimate the ionospheric TEC along a line-of-sight to the Moon and using the same radio telescope.
549 - J. Wang , L. Cao , X. M. Meng 2014
We reported the photometric calibration of Lunar-based Ultraviolet telescope (LUT), the first robotic astronomical telescope working on the lunar surface, for its first six months of operation on the lunar surface. Two spectral datasets (set A and B) from near-ultraviolet (NUV) to optical band were constructed for 44 International Ultraviolet Explorer (IUE) standards, because of the LUTs relatively wide wavelength coverage. Set A were obtained by extrapolating the IUE NUV spectra ($lambda<3200AA$) to optical band basing upon the theoretical spectra of stellar atmosphere models. Set B were exactly the theoretical spectra from 2000AA to 8000AA extracted from the same model grid. In total, seven standards have been observed in 15 observational runs until May 2014. The calibration results show that the photometric performance of LUT is highly stable in its first six months of operation. The magnitude zero points obtained from the two spectral datasets are also consistent with each other, i.e., $mathrm{zp=17.54pm0.09}$mag (set A) and $mathrm{zp=17.52pm0.07}$mag (set B).
73 - Justin D. Bray 2016
The use of the Moon as a detector volume for ultra-high-energy neutrinos and cosmic rays, by searching for the Askaryan radio pulse produced when they interact in the lunar regolith, has been attempted by a range of projects over the past two decades . In this contribution, I discuss some of the technical considerations relevant to these experiments, and their consequent sensitivity to ultra-high-energy particles. I also discuss some possible future experiments, and highlight their potential.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا