ترغب بنشر مسار تعليمي؟ اضغط هنا

Spatial resolution of a {mu}PIC-based neutron imaging detector

152   0   0.0 ( 0 )
 نشر من قبل Joseph Parker
 تاريخ النشر 2013
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our prototype detector system, employing a micro-pattern gaseous detector known as the micro-pixel chamber ({mu}PIC) coupled with a field-programmable-gate-array-based data acquisition system, combines 100{mu}m-level spatial and sub-{mu}s time resolutions with excellent gamma rejection and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. From data taken at the Materials and Life Science Experimental Facility within the Japan Proton Accelerator Research Complex (J-PARC), the spatial resolution was found to be approximately Gaussian with a sigma of 103.48 +/- 0.77 {mu}m (after correcting for beam divergence). This is a significant improvement over that achievable with our previous reconstruction method (334 +/- 13 {mu}m), and compares well with conventional neutron imaging detectors and with other high-rate detectors currently under development. Further, a detector simulation indicates that a spatial resolution of less than 60 {mu}m may be possible with optimization of the gas characteristics and {mu}PIC structure. We also present an example of imaging combined with neutron resonance absorption spectroscopy.

قيم البحث

اقرأ أيضاً

We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber ({mu}PIC) coupled with a field-programmable-gate-array-based data acquisition system. Our detector system combines 100{mu}m-level spatial and sub-{mu}s time resolutions with a low gamma sensitivity of less than 10^-12 and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. In the present paper, we introduce the detector system and present several test measurements performed at NOBORU (BL10), J-PARC to demonstrate the capabilities of our prototype. We also discuss future improvements to the spatial resolution and rate performance.
We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in neutron r adiography at high-intensity neutron sources. The prototype system, with an active area of 10cm x 10cm and operated at a gas pressure of 2 atm, measures both the energy deposition (via time-over-threshold) and 3-dimensional track of each neutron-induced event, allowing the reconstruction of the neutron interaction point with improved accuracy. Using a simple position reconstruction algorithm, a spatial resolution of 349 +/- 36 microns was achieved, with further improvement expected. The detailed tracking allows strong rejection of background gamma-rays, resulting in an effective gamma sensitivity of 10^-12 or less, coupled with stable, robust neutron identification. The detector also features a time resolution of 0.6 microseconds.
In the framework of the ATTRACT-uRANIA project, funded by the European Community, we are developing an innovative neutron imaging detector based on micro-Resistive WELL ($mu$ -RWELL) technology. The $mu$ -RWELL, based on the resistive detector concep t, ensuring an efficient spark quenching mechanism, is a highly reliable device. It is composed by two main elements: a readout-PCB and a cathode. The amplification stage for this device is embedded in the readout board through a resistive layer realized by means of an industrial process with DLC (Diamond-Like Carbon). A thin layer of B$_4$C on the copper surface of the cathode allows the thermal neutrons detection through the release of $^7$Li and $alpha$ particles in the active volume. This technology has been developed to be an efficient and convenient alternative to the $^3$He shortage. The goal of the project is to prove the feasibility of such a novel neutron detector by developing and testing small planar prototypes with readout boards suitably segmented with strip or pad read out, equipped with existing electronics or readout in current mode. Preliminary results from the test with different prototypes, showing a good agreement with the simulation, will be presented together with construction details of the prototypes and the future steps of the project.
76 - N. Naganawa , S. Awano , M. Hino 2016
We have been developing a neutron detector with spatial resolution of submicron by loading 6Li into fine-grained nuclear emulsion. By exposure to thermal neutrons, tracks from neutron capture events were observed. From their grain density, spatial re solution was estimated. Detection efficiency was also measured by an experiment with cold neutrons.
107 - N. Naganawa , T. Ariga , S. Awano 2018
A new type of cold/ultracold neutron detector that can realize a spatial resolution of less than 100 nm was developed using nuclear emulsion. The detector consists of a fine-grained nuclear emulsion coating and a 50-nm thick $^{10}$B$_4$C layer for t he neutron conversion. The detector was exposed to cold and ultracold neutrons (UCNs) at the J-PARC. Detection efficiencies were measured as (0.16$pm$0.02)% and (12$pm$2)% for cold and ultracold neutrons consistently with the $^{10}$B content in the converter. Positions of individual neutrons can be determined by observing secondary particle tracks recorded in the nuclear emulsion. The spatial resolution of incident neutrons were found to be in the range of 11-99 nm in the angle region of tan$thetaleq 1.9$, where $theta$ is the angle between a recorded track and the normal direction of the converter layer. The achieved spatial resolution corresponds to the improvement of one or two orders of magnitude compared with conventional techniques and it is comparable with the wavelength of UCNs.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا