ترغب بنشر مسار تعليمي؟ اضغط هنا

First operation and performance of a 200 lt double phase LAr LEM-TPC with a 40x76 cm^2 readout

244   0   0.0 ( 0 )
 نشر من قبل Andre Rubbia
 تاريخ النشر 2013
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

In this paper we describe the design, construction, and operation of a first large area double-phase liquid argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). The detector has a maximum drift length of 60 cm and the readout consists of a $40times 76$ cm$^2$ LEM and 2D projective anode to multiply and collect drifting charges. Scintillation light is detected by means of cryogenic PMTs positioned below the cathode. To record both charge and light signals, we have developed a compact acquisition system, which is scalable up to ton-scale detectors with thousands of charge readout channels. The acquisition system, as well as the design and the performance of custom-made charge sensitive preamplifiers, are described. The complete experimental setup has been operated for a first time during a period of four weeks at CERN in the cryostat of the ArDM experiment, which was equipped with liquid and gas argon purification systems. The detector, exposed to cosmic rays, recorded events with a single-channel signal-to-noise ratio in excess of 30 for minimum ionising particles. Cosmic muon tracks and their $delta$-rays were used to assess the performance of the detector, and to estimate the liquid argon purity and the gain at different amplification fields.

قيم البحث

اقرأ أيضاً

A double-phase argon Time Projection Chamber (TPC), with an active mass of 185 g, has been designed and constructed for the Recoil Directionality (ReD) experiment. The aim of the ReD project is to investigate the directional sensitivity of argon-base d TPCs via columnar recombination to nuclear recoils in the energy range of interest (20-200 keV$_{nr}$) for direct dark matter searches. The key novel feature of the ReD TPC is a readout system based on cryogenic Silicon Photomultipliers, which are employed and operated continuously for the first time in an argon TPC. Over the course of six months, the ReD TPC was commissioned and characterised under various operating conditions using $gamma$-ray and neutron sources, demonstrating remarkable stability of the optical sensors and reproducibility of the results. The scintillation gain and ionisation amplification of the TPC were measured to be $g_1 = (0.194 pm 0.013)$ PE/photon and $g_2 = (20.0 pm 0.9)$ PE/electron, respectively. The ratio of the ionisation to scintillation signals (S2/S1), instrumental for the positive identification of a candidate directional signal induced by WIMPs, has been investigated for both nuclear and electron recoils. At a drift field of 183 V/cm, an S2/S1 dispersion of 12% was measured for nuclear recoils of approximately 60-90 keV$_{nr}$, as compared to 18% for electron recoils depositing 60 keV of energy. The detector performance reported here meets the requirements needed to achieve the principal scientific goals of the ReD experiment in the search for a directional effect due to columnar recombination. A phenomenological parameterisation of the recombination probability in LAr is presented and employed for modeling the dependence of scintillation quenching and charge yield on the drift field for electron recoils between 50-500 keV and fields up to 1000 V/cm.
In this paper we present results from a test of a small Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector concept provides a 3D-tracking and calorimetric device capable of charge amplification, suited for nex t-generation neutrino detectors and possibly direct Dark Matter searches. During a test of a 3~lt chamber equipped with a 10$times$10~cm$^2$ readout, cosmic muon data was recorded during three weeks of data taking. A maximum gain of 6.5 was achieved and the liquid argon was kept pure enough to ensure 20~cm drift (O(ppb)~O$_2$ equivalent).
ARGONTUBE is a liquid argon time projection chamber (TPC) with an electron drift length of up to 5 m equipped with cryogenic charge-sensitive preamplifiers. In this work, we present results on its performance including a comparison of the new cryogen ic charge-sensitive preamplifiers with the previously used room-temperature-operated charge preamplifiers.
69 - C.Cantini 2013
We report on the successful operation of a double phase Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) equipped with two dimensional projective anodes with dimensions 10$times$10 cm$^2$, and with a maximum drift length o f 21 cm. The anodes were manufactured for the first time from a single multilayer printed circuit board (PCB). Various layouts of the readout views have been tested and optimised. In addition, the ionisation charge was efficiently extracted from the liquid to the gas phase with a single grid instead of two previously. We studied the response and the gain of the detector to cosmic muon tracks. To study long-term stability over several weeks, we continuously operated the chamber at fixed electric field settings. We reproducibly observe that after an initial decrease with a characteristic time of $tauapprox 1.6$ days, the observed gain is stable. In 46 days of operation, a total of 14.6 million triggers have been collected at a stable effective gain of $G_inftysim 15$ corresponding to a signal-to-noise ratio $(S/N)gtrsim 60$ for minimum ionising tracks. During the full period, eight discharges across the LEM were observed. A maximum effective gain of 90 was also observed, corresponding to a signal-to-noise ratio $(S/N)gtrsim 400$ for minimum ionising tracks, or $S/Napprox10$ for an energy deposition of 15 keV on a single readout channel.
667 - H.Chen , J.Evans , J.Fried 2018
Short Baseline Near Detector (SBND), which is a 260-ton LAr TPC as near detector in Short Baseline Neutrino (SBN) program, consists of 11,264 TPC readout channels. As an enabling technology for noble liquid detectors in neutrino experiments, cold ele ctronics developed for extremely low temperature (77K - 89K) decouples the electrode and cryostat design from the readout design. With front-end electronics integrated with detector electrodes, the noise is independent of the fiducial volume and about half as with electronics at room temperature. Digitization and signal multiplexing to high speed serial links inside cryostat result in large reduction in the quantity of cables (less outgassing) and the number of feed-throughs, therefore minimize the penetration and simplify the cryostat design. Being considered as an option for the TPC readout, several Commercial-Off-The-Shelf (COTS) ADC chips have been identified as good candidates for operation in cryogenic temperature after initial screening test. Because Hot Carrier Effects (HCE) degrades CMOS device lifetime, one candidate, ADI AD7274 fabricated in TSMC 350nm CMOS technology, of which lifetime at cryogenic temperature is studied. The lifetime study includes two phases, the exploratory phase and the validation phase. This paper describes the test method, test setup, observations in the exploratory phase and the validation phase. Based on the current test data, the preliminary lifetime projection of AD7274 is about 6.1 $times$ $10^6$ years at 2.5V operation at cryogenic temperature, which means the HCE degradation is negligible during the SBND service life.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا