ترغب بنشر مسار تعليمي؟ اضغط هنا

The Fourth US Naval Observatory CCD Astrograph Catalog (UCAC4)

114   0   0.0 ( 0 )
 نشر من قبل Norbert Zacharias
 تاريخ النشر 2012
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The fourth United States Naval Observatory (USNO) CCD Astrograph Catalog, UCAC4 was released in August 2012 (double-sided DVD and CDS data center Vizier catalog I/322). It is the final release in this series and contains over 113 million objects; over 105 million of them with proper motions. UCAC4 is an updated version of UCAC3 with about the same number of stars also covering all-sky. Bugs were fixed, Schmidt plate survey data were avoided, and precise 5-band photometry were added. Astrograph observations have been supplemented for bright stars by FK6, Hipparcos and Tycho-2 data to compile a UCAC4 star catalog complete to about magnitude R = 16. Epoch 1998 to 2004 positions are obtained from observations with the 20 cm aperture USNO Astrographs red lens, equipped with a 4k by 4k CCD. Mean positions and proper motions are derived by combining these observations with over 140 ground- and space-based catalogs, including Hipparcos/Tycho and the AC2000.2, as well as unpublished measures of over 5000 plates from other astrographs. For most of the faint stars the first epoch plates from the Southern Proper Motion (SPM) and the Northern Proper Motion (NPM) programs form the basis for proper motions. These data are supplemented by 2MASS near-IR photometry for about 110 million stars and 5-band (B,V,g,r,i) APASS data for over 51 million stars. Thus the published UCAC4, as were UCAC3 and UCAC2, is a compiled catalog with the UCAC observational program being a major component. The positional accuracy of stars in UCAC4 at mean epoch is about 15 to 100 mas per coordinate, depending on magnitude, while the formal errors in proper motions range from about 1 to 10 mas/yr depending on magnitude and observing history. Systematic errors in proper motions are estimated to be about 1 to 4 mas/yr.



قيم البحث

اقرأ أيضاً

The third US Naval Observatory (USNO) CCD Astrograph Catalog, UCAC3 was released at the IAU General Assembly on 2009 August 10. It is the first all-sky release in this series and contains just over 100 million objects, about 95 million of them with p roper motions, covering about R = 8 to 16 magnitudes. Current epoch positions are obtained from the observations with the 20 cm aperture USNO Astrographs red lens, equipped with a 4k by 4k CCD. Proper motions are derived by combining these observations with over 140 ground- and space-based catalogs, including Hipparcos/Tycho and the AC2000.2, as well as unpublished measures of over 5000 plates from other astrographs. For most of the faint stars in the Southern Hemisphere the Yale/San Juan first epoch plates from the SPM program (YSJ1) form the basis for proper motions. These data are supplemented by all-sky Schmidt plate survey astrometry and photometry obtained from the SuperCOSMOS project, as well as 2MASS near-IR photometry. Major differences of UCAC3 data as compared to UCAC2 include a completely new raw data reduction with improved control over systematic errors in positions, significantly improved photometry, slightly deeper limiting magnitude, coverage of the north pole region, greater completeness by inclusion of double stars and weak detections. This of course leads to a catalog which is not as clean as UCAC2 and problem areas are outlined for the user in this paper. The positional accuracy of stars in UCAC3 is about 15 to 100 mas per coordinate, depending on magnitude, while the errors in proper motions range from 1 to 10 mas/yr depending on magnitude and observing history, with a significant improvement over UCAC2 achieved due to the re-reduced SPM data and inclusion of more astrograph plate data unavailable at the time of UCAC2.
Between 1997 and 2004 several observing runs were conducted mainly with the CTIO 0.9 m to image ICRF counterparts (mostly QSOs) in order to determine accurate optical positions. Contemporary to these deep CCD images the same fields were observed with the US Naval Observatory (USNO) astrograph in the same bandpass. They provide accurate positions on the Hipparcos/Tycho-2 system for stars in the 10 to 16 magnitude range used as reference stars for the deep CCD imaging data. Here we present final optical position results of 413 sources based on reference stars obtained by dedicated astrograph observations which were reduced following 2 different procedures. These optical positions are compared to radio VLBI positions. The current optical system is not perfectly aligned to the ICRF radio system with rigid body rotation angles of 3 to 5 mas (= 3 sigma level) found between them for all 3 axes. Furthermore, statistically, the optical minus radio position differences are found to exceed the total, combined, known errors in the observations. Systematic errors in the optical reference star positions as well as physical offsets between the centers of optical and radio emissions are both identified as likely causes. A detrimental, astrophysical, random noise (DARN) component is postulated to be on about the 10 mas level. If confirmed by future observations, this could severely limit the Gaia to ICRF reference frame alignment accuracy to an error of about 0.5 mas per coordinate axis with the current number of sources envisioned to provide the link. A list of 36 ICRF sources without the detection of an optical counterpart to a limiting magnitude of about R=22 is provided as well.
URAT1 is an observational, astrometric catalog covering most of the Dec >= -15 deg area and a magnitude range of about R = 3 to 18.5. Accurate positions (typically 10 to 30 mas standard error) are given for over 228 million objects at a mean epoch ar ound 2013.5. For the over 188 million objects matched with the 2MASS point source catalog proper motions (typically 5 to 7 mas/yr std. errors) are provided. These data are supplemented by 2MASS and APASS photometry. Observations, reductions and catalog construction are described together with results from external data verifications. The catalog data are served by CDS, Starsbourg (I/329). There is no DVD release.
The Brorfelde Schmidt CCD Catalog (BSCC) contains about 13.7 million stars, north of +49 deg Declination with precise positions and V, R photometry. The catalog has been constructed from the reductions of 18,667 CCD frames observed with the Brorfelde Schmidt Telescope between 2000 and 2007. The Tycho-2 catalog was used for astrometric and photometric reference stars. Errors of individual positions are about 20 to 200 mas for stars in the R = 10 to 18 mag range. External comparisons with 2MASS and SDSS reveal possible small systematic errors in the BSCC of up to about 30 mas. The catalog is supplemented with J, H, and K_s magnitudes from the 2MASS catalog. The catalog data file (about 550 MB ASCII, compressed) will be made available at the Strasbourg Data Center (CDS).
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا