ترغب بنشر مسار تعليمي؟ اضغط هنا

PyCosmic: a robust method to detect cosmics in CALIFA and other fiber-fed integral-field spectroscopy datasets

148   0   0.0 ( 0 )
 نشر من قبل Bernd Husemann
 تاريخ النشر 2012
  مجال البحث فيزياء
والبحث باللغة English
 تأليف B. Husemann




اسأل ChatGPT حول البحث

[Abridged] Detecting cosmic ray hits (cosmics) in fiber-fed IFS data of single exposures is a challenging task, because of the complex signal recorded by IFS instruments. Existing detection algorithms are commonly found to be unreliable in the case of IFS data and the optimal parameter settings are usually unknown a-priori for a given dataset. The CALIFA survey generates hundreds of IFS datasets for which a reliable and robust detection algorithm for cosmics is required as an important part of the fully automatic CALIFA data reduction pipeline. We developed a novel algorithm, PyCosmic, which combines the edge-detection algorithm of L.A.Cosmic with a point-spread function convolution scheme. We generated mock data to compute the efficiency of different algorithms for a wide range of characteristic fibre-fed IFS datasets using the PMAS and VIMOS IFS instruments as representative cases. PyCosmic is the only algorithm that achieves an acceptable detection performance for CALIFA data. We find that PyCosmic is the most robust tool with a detection rate of >~90% and a false detection rate <5% for any of the tested IFS data. It has one less free parameter than the L.A.Cosmic algorithm. Only for strongly undersampled IFS data does L.A.Cosmic exceed the performance of PyCosmic by a few per cent. DCR never reaches the efficiency of the other two algorithms and should only be used if computational speed is a concern. Thus, PyCosmic appears to be the most versatile cosmics detection algorithm for IFS data. It is implemented in the new CALIFA data reduction pipeline as well as in recen



قيم البحث

اقرأ أيضاً

Direct imaging instruments have the spatial resolution to resolve exoplanets from their host star. This enables direct characterization of the exoplanets atmosphere, but most direct imaging instruments do not have spectrographs with high enough resol ving power for detailed atmospheric characterization. We investigate the use of a single-mode diffraction-limited integral-field unit that is compact and easy to integrate into current and future direct imaging instruments for exoplanet characterization. This achieved by making use of recent progress in photonic manufacturing to create a single-mode fiber-fed image reformatter. The fiber-link is created with 3D printed lenses on top of a single-mode multi-core fiber that feeds an ultrafast laser inscribed photonic chip that reformats the fiber into a pseudo-slit. We then couple it to a first-order spectrograph with a triple stacked volume phase holographic grating for a high efficiency over a large bandwidth. The prototype system has had a successful first-light observing run at the 4.2 meter William Herschel Telescope. The measured on-sky resolving power is between 2500 and 3000, depending on the wavelength. With our observations we show that single-mode integral-field spectroscopy is a viable option for current and future exoplanet imaging instruments.
A generic fiber positioning strategy and a fabrication path are presented for microlens-fiber-coupled integral field units. It is assumed that microlens-produced micro-images are carried to the spectrograph input through step-index,multi-mode fiber, but our results apply to micro-pupil reimaging applications as well. Considered are the performance trades between the filling percentage of the fiber core with the micro-image versus throughput and observing efficiency.A merit function is defined as the product of the transmission efficiency and the etendue loss. For a hexagonal packing of spatial elements, the merit function has been found to be maximized to 94% of an ideal fiber IFU merit value (which has zero transmission loss and does not increase the etendue) with a microlens-fiber alignment (centering) tolerance of 1 um RMS. The maximum acceptable relative tilt between the fiber and the microlens face has been analyzed through optical modeling and found to be 0.3 degree RMS for input f-ratio slower than f/3.5 but it is much more relaxed for faster beams. Several options of fabricating fiber holders have been compared to identify cost-effective solutions that deliver the desired fiber positioning accuracy. Femto-second laser-drilling methods deliver holes arrayed on plates with a position and diameter accuracy of 1.5 um RMS, and with an aspect ratio of 1:10. A commercial vendor produces plates with thickness of 5 mm, but with similar (1 um RMS) positioning accuracy. Both of these techniques are found to be moderately expensive. A purely photo-lithographic technique performed at WCAM (a facility at the University of Wisconsin, Madison), in tandem with deep reactive ion etching, has been used to produce a repeatable recipe with 100% yield. Photo-lithography is more precise (0.5 um RMS) in terms of hole positioning and similar diameter accuracy (1 um RMS).
We describe and discuss the selection procedure and statistical properties of the galaxy sample used by the Calar Alto Legacy Integral Field Area Survey (CALIFA), a public legacy survey of 600 galaxies using integral field spectroscopy. The CALIFA mo ther sample was selected from the Sloan Digital Sky Survey (SDSS) DR7 photometric catalogue to include all galaxies with an r-band isophotal major axis between 45 and 79.2 and with a redshift 0.005 < z < 0.03. The mother sample contains 939 objects, 600 of which will be observed in the course of the CALIFA survey. The selection of targets for observations is based solely on visibility and thus keeps the statistical properties of the mother sample. By comparison with a large set of SDSS galaxies, we find that the CALIFA sample is representative of galaxies over a luminosity range of -19 > Mr > -23.1 and over a stellar mass range between 10^9.7 and 10^11.4Msun. In particular, within these ranges, the diameter selection does not lead to any significant bias against - or in favour of - intrinsically large or small galaxies. Only below luminosities of Mr = -19 (or stellar masses < 10^9.7Msun) is there a prevalence of galaxies with larger isophotal sizes, especially of nearly edge-on late-type galaxies, but such galaxies form < 10% of the full sample. We estimate volume-corrected distribution functions in luminosities and sizes and show that these are statistically fully compatible with estimates from the full SDSS when accounting for large-scale structure. We also present a number of value-added quantities determined for the galaxies in the CALIFA sample. We explore different ways of characterizing the environments of CALIFA galaxies, finding that the sample covers environmental conditions from the field to genuine clusters. We finally consider the expected incidence of active galactic nuclei among CALIFA galaxies.
The CHIRON optical high-resolution echelle spectrometer was commissioned at the 1.5m telescope at CTIO in 2011. The instrument was designed for high throughput and stability, with the goal of monitoring radial velocities of bright stars with high pre cision and high cadence for the discovery of low-mass exoplanets. Spectral resolution of R=79,000 is attained when using a slicer with a total (including telescope and detector) efficiency of 6% or higher, while a resolution of R=136,000 is available for bright stars. A fixed spectral range of 415 to 880 nm is covered. The echelle grating is housed in a vacuum enclosure and the instrument temperature is stabilized to +-0.2deg. Stable illumination is provided by an octagonal multimode fiber with excellent light-scrambling properties. An iodine cell is used for wavelength calibration. We describe the main optics, fiber feed, detector, exposure-meter, and other aspects of the instrument, as well as the observing procedure and data reduction.
We present here CAFE, the Calar Alto Fiber-fed Echelle spectrograph, a new instrument built at the Centro Astronomico Hispano Aleman (CAHA). CAFE is a single fiber, high-resolution ($Rsim$70000) spectrograph, covering the wavelength range between 365 0-9800AA. It was built on the basis of the common design for Echelle spectrographs. Its main aim is to measure radial velocities of stellar objects up to $Vsim$13-14 mag with a precision as good as a few tens of $m s^{-1}$. To achieve this goal the design was simplified at maximum, removing all possible movable components, the central wavelength is fixed, so the wavelentgth coverage; no filter wheel, one slit and so on, with a particular care taken in the thermal and mechanical stability. The instrument is fully operational and publically accessible at the 2.2m telescope of the Calar Alto Observatory. In this article we describe (i) the design, summarizing its manufacturing phase; (ii) characterize the main properties of the instrument; (iii) describe the reduction pipeline; and (iv) show the results from the first light and commissioning runs. The preliminar results indicate that the instrument fulfill the specifications and it can achieve the foreseen goals. In particular, they show that the instrument is more efficient than anticipated, reaching a $S/Nsim$20 for a stellar object as faint as $Vsim$14.5 mag in $sim$2700s integration time. The instrument is a wonderful machine for exoplanetary research (by studying large samples of possible systems cotaining massive planets), galactic dynamics (high precise radial velocities in moving groups or stellar associations) or astrochemistry.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا