ترغب بنشر مسار تعليمي؟ اضغط هنا

Is a co-rotating Dark Disk a threat to Dark Matter Directional Detection ?

55   0   0.0 ( 0 )
 نشر من قبل Julien Billard
 تاريخ النشر 2012
  مجال البحث فيزياء
والبحث باللغة English
 تأليف J. Billard




اسأل ChatGPT حول البحث

Recent N-Body simulations are in favor of the presence of a co-rotating Dark Disk that might contribute significantly (10%-50%) to the local Dark Matter density. Such substructure could have dramatic effect on directional detection. Indeed, in the case of a null lag velocity, one expects an isotropic WIMP velocity distribution arising from the Dark Disk contribution, which might weaken the strong angular signature expected in directional detection. For a wide range of Dark Disk parameters, we evaluate in this Letter the effect of such dark component on the discovery potential of upcoming directional detectors. As a conclusion of our study, using only the angular distribution of nuclear recoils, we show that Dark Disk models as suggested by recent N-Body simulations will not affect significantly the Dark Matter reach of directional detection, even in extreme configurations.

قيم البحث

اقرأ أيضاً

97 - J. Billard 2010
Directional detection of galactic Dark Matter is a promising search strategy for discriminating genuine WIMP events from background ones. However, to take full advantage of this powerful detection method, one need to be able to extract information fr om an observed recoil map to identify a WIMP signal. We present a comprehensive formalism, using a map-based likelihood method allowing to recover the main incoming direction of the signal, thus proving its galactic origin, and the corresponding significance. Constraints are then deduced in the (sigma_n, m_chi) plane.
60 - F. Mayet 2010
Directional detection of galactic Dark Matter is a promising search strategy for discriminating geniune WIMP events from background ones. We present technical progress on gaseous detectors as well as recent phenomenological studies, allowing the design and construction of competitive experiments.
112 - F. Mayet 2012
Directional detection is a promising Dark Matter search strategy. Taking advantage on the rotation of the Solar system around the galactic center through the Dark Matter halo, it allows to show a direction dependence of WIMP events that may be a powe rful tool to identify genuine WIMP events as such. Directional detection strategy requires the simultaneous measurement of the energy and the 3D track of low energy recoils, which is a common challenge for all current projects of directional detectors.
72 - D. Santos 2011
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of track s down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. The first results on low energy nuclear recoils (H, F) obtained with a low mono-energetic neutron field are presented. The discovery potential of this search strategy is discussed and illustrated by a realistic case accessible to MIMAC.
102 - M. Cadeddu , M. Lissia , P. Agnes 2017
We examine the sensitivity of a large scale two-phase liquid argon detector to the directionality of the dark matter signal. This study was performed under the assumption that, above 50 keV of recoil energy, one can determine (with some resolution) t he direction of the recoil nucleus without head-tail discrimination, as suggested by past studies that proposed to exploit the dependence of columnar recombination on the angle between the recoil nucleus direction and the electric field. In this paper we study the differential interaction recoil rate as a function of the recoil direction angle with respect to the zenith for a detector located at the Laboratori Nazionali del Gran Sasso and we determine its diurnal and seasonal modulation. Using a likelihood-ratio based approach we show that, with the angular information alone, 100 events are enough to reject the isotropic hypothesis at three standard deviation level. For an exposure of 100 tonne years this would correspond to a spin independent WIMP-nucleon cross section of about 10^-46 cm^2 at 200 GeV WIMP mass. The results presented in this paper provide strong motivation for the experimental determination of directional recoil effects in two-phase liquid argon detectors.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا