ترغب بنشر مسار تعليمي؟ اضغط هنا

Absolute frequency measurement of 1S0 (F = 1/2) - 3P0 (F = 1/2) transition of 171Yb atoms in a one-dimensional optical lattice at KRISS

213   0   0.0 ( 0 )
 نشر من قبل Chang Yong Park
 تاريخ النشر 2011
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We measured the absolute frequency of the optical clock transition 1S0 (F = 1/2) - 3P0 (F = 1/2) of 171Yb atoms confined in a one-dimensional optical lattice and it was determined to be 518 295 836 590 863.5(8.1) Hz. The frequency was measured against Terrestrial Time (TT; the SI second on the geoid) by using an optical frequency comb of which the frequency was phase-locked to an H-maser as a flywheel oscillator traceable to TT. The magic wavelength was also measured as 394 798.48(79) GHz. The results are in good agreement with two previous measurements of other institutes within the specified uncertainty of this work.



قيم البحث

اقرأ أيضاً

We report a measurement of the absolute frequency of the 1S0-3P0 transition in the 171Yb optical lattice clock at KRISS (KRISS-Yb1) for 14 months, which was referenced to the SI second by primary and secondary standards worldwide via TAI (Internation al Atomic Time). The determined absolute frequency is 518 295 836 590 863.75(14) Hz with the relative frequency uncertainty of 2.6x10^-16, which agrees well with other reports. This result is expected to contribute to the future update of the CIPM recommendation frequency of the secondary frequency standards.
We measured the absolute frequency of the $^1S_0$ - $^3P_0$ transition of $^{171}$Yb atoms confined in a one-dimensional optical lattice relative to the SI second. The determined frequency was 518 295 836 590 863.38(57) Hz. The uncertainty was reduce d by a factor of 14 compared with our previously reported value in 2013 due to the significant improvements in decreasing the systematic uncertainties. This result is expected to contribute to the determination of a new recommended value for the secondary representations of the second.
The highly forbidden $^2$S$_{1/2} rightarrow ^2$F$_{7/2}$ electric octupole transition in $^{171}$Yb$^+$ is a potential candidate for a redefinition of the SI second. We present a measurement of the absolute frequency of this optical transition, perf ormed using a frequency link to International Atomic Time to provide traceability to the SI second. The $^{171}$Yb$^+$ optical frequency standard was operated for 76% of a 25-day period, with the absolute frequency measured to be 642 121 496 772 645.14(26) Hz. The fractional uncertainty of $4.0 times 10 ^{-16}$ is comparable to that of the best previously reported measurement, which was made by a direct comparison to local caesium primary frequency standards.
Transition frequencies were determined for transitions in Ra in an atomic beam and for reference lines in Te$_2$ molecules in a vapor cell. The absolute frequencies were calibrated against a GPS stabilized Rb-clock by means of an optical frequency co mb. The 7s$^2,^1$S$_0$(F = 1/2)-7s7p$,^1$P$_1$(F = 3/2) transition in $^{225}$Ra was determined to be $621,042,124(2),$MHz. The measurements provide input for designing efficient and robust laser cooling of Ra atoms in preparation of a search for a permanent electric dipole moment in Ra isotopes.
171 - M. Schacht , M. Schauer 2013
A data acquisition system is described that is designed to stabilize cooling and probe rates to maximize detection sensitivity and minimize possible systematic errors due to correlations between drifting experimental conditions and varying drive para meters. Experimental parameters that affect the Yb171 5D3/2 hyperfine state preparation and detection efficiency are characterized and optimized. A set of wait times for optimal sampling of the D3/2(F=2) lifetime is chosen and used to measure that lifetime with high statistical sensitivity. A systematic variation in this lifetime seems to be apparent. The source of the variation was not identified, but ion number and cooling rate appear to be ruled out. A net determination is made of tau=61.8ms+-(0.6)_stat+-(6.4)_sys which is significantly longer than other measurements of the same quantity. An alternate shelving scheme is proposed that would provide S-D state discrimination for Yb even isotopes as well as improved sensitivity for D state hyperfine discrimination in odd isotopes.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا