ترغب بنشر مسار تعليمي؟ اضغط هنا

A New Comprehensive 2-D Model of the Point Spread Functions of the XMM-Newton EPIC Telescopes : Spurious Source Suppression and Improved Positional Accuracy

58   0   0.0 ( 0 )
 نشر من قبل Dr. Andy Read
 تاريخ النشر 2011
  مجال البحث فيزياء
والبحث باللغة English
 تأليف A. M. Read




اسأل ChatGPT حول البحث

We describe here a new full 2-D parameterization of the PSFs of the three XMM-Newton EPIC telescopes as a function of instrument, energy, off-axis angle and azimuthal angle, covering the whole field-of-view of the three EPIC detectors. It models the general PSF envelopes, the primary and secondary spokes, their radial dependencies, and the large-scale azimuthal variations. This PSF model has been constructed via the stacking and centering of a large number of bright, but not significantly piled-up point sources from the full field-of-view of each EPIC detector, and azimuthally filtering the resultant PSF envelopes to form the spoke structures and the gross azimuthal shapes observed. This PSF model is available for use within the XMM-Newton Science Analysis System via the usage of Current Calibration Files XRTi_XPSF_0011.CCF and lat



قيم البحث

اقرأ أيضاً

89 - C.-T.J. Chen 2018
We present an X-ray point-source catalog from the XMM-Large Scale Structure survey region (XMM-LSS), one of the XMM-Spitzer Extragalactic Representative Volume Survey (XMM-SERVS) fields. We target the XMM-LSS region with $1.3$ Ms of new XMM-Newton AO -15 observations, transforming the archival X-ray coverage in this region into a 5.3 deg$^2$ contiguous field with uniform X-ray coverage totaling $2.7$ Ms of flare-filtered exposure, with a $46$ ks median PN exposure time. We provide an X-ray catalog of 5242 sources detected in the soft (0.5-2 keV), hard (2-10 keV), and/or full (0.5-10 keV) bands with a 1% expected spurious fraction determined from simulations. A total of 2381 new X-ray sources are detected compared to previous source catalogs in the same area. Our survey has flux limits of $1.7times10^{-15}$, $1.3times10^{-14}$, and $6.5times10^{-15}$ erg cm$^{-2}$ s$^{-1}$ over 90% of its area in the soft, hard, and full bands, respectively, which is comparable to those of the XMM-COSMOS survey. We identify multiwavelength counterpart candidates for 99.9% of the X-ray sources, of which 93% are considered as reliable based on their matching likelihood ratios. The reliabilities of these high-likelihood-ratio counterparts are further confirmed to be $approx 97$% reliable based on deep Chandra coverage over $approx 5$% of the XMM-LSS region. Results of multiwavelength identifications are also included in the source catalog, along with basic optical-to-infrared photometry and spectroscopic redshifts from publicly available surveys. We compute photometric redshifts for X-ray sources in 4.5 deg$^2$ of our field where forced-aperture multi-band photometry is available; $>70$% of the X-ray sources in this subfield have either spectroscopic or high-quality photometric redshifts.
Reliable timing calibration is essential for the accurate comparison of XMM-Newton light curves with those from other observatories, to ultimately use them to derive precise physical quantities. The XMM-Newton timing calibration is based on pulsar an alysis. However, as pulsars show both timing noise and glitches, it is essential to monitor these calibration sources regularly. To this end, the XMM-Newton observatory performs observations twice a year of the Crab pulsar to monitor the absolute timing accuracy of the EPIC-pn camera in the fast Timing and Burst modes. We present the results of this monitoring campaign, comparing XMM-Newton data from the Crab pulsar (PSR B0531+21) with radio measurements. In addition, we use five pulsars (PSR J0537-69, PSR B0540-69, PSR B0833-45, PSR B1509-58 and PSR B1055-52) with periods ranging from 16 ms to 197 ms to verify the relative timing accuracy. We analysed 38 XMM-Newton observations (0.2-12.0 keV) of the Crab taken over the first ten years of the mission and 13 observations from the five complementary pulsars. All the data were processed with the SAS, the XMM-Newton Scientific Analysis Software, version 9.0. Epoch folding techniques coupled with chi^{2} tests were used to derive relative timing accuracies. The absolute timing accuracy was determined using the Crab data and comparing the time shift between the main X-ray and radio peaks in the phase folded light curves. The relative timing accuracy of XMM-Newton is found to be better than 10^{-8}. The strongest X-ray pulse peak precedes the corresponding radio peak by 306pm9 mus, which is in agreement with other high energy observatories such as Chandra, INTEGRAL and RXTE. The derived absolute timing accuracy from our analysis is pm48 mus.
Our understanding of the background of the EPIC/pn camera onboard XMM-Newton is incomplete. This affects the study of extended sources and can influence the predictions of the background of future X-ray missions. We provide new results based on the a nalysis of the largest data set ever used. We focus on the unconcentrated component of the EPIC/pn background - supposedly related to cosmic rays interacting with the telescope. We find that the out-field of view region of the pn detector is actually exposed to the sky. After cleaning from the sky contamination, the unconcentrated background does not show significant spatial variations and its time behaviour is anti-correlated with the solar cycle. We find a very tight, linear correlation between unconcentrated backgrounds detected in the EPIC/pn and MOS2 cameras: this permits the correct evaluation of the pn unconcentrated background of each exposure on the basis of MOS2 data, avoiding the use (as usual) of the contaminated pn regions. We find a tight, linear correlation between the pn unconcentrated background and the proton flux in the 630-970 MeV energy band measured by SOHO/EPHIN. Through this relationship we quantify the contribution of cosmic ray interactions to the pn unconcentrated background and we find a second source which contributes to the pn unconcentrated background for a significant fraction (30%-70%), that does not vary with time and is roughly isotropic. Hard X-ray photons of the CXB satisfy all the known properties of this new component. Our findings provide an important observational confirmation of simulation results on ATHENA.
We present an empirical correction of sky coordinates of X-ray photons obtained with the XIS aboard the Suzaku satellite to improve the source position accuracy and restore the point-spread function (PSF). The XIS images are known to have an uncertai nty in position of up to 1 arcmin, and to show considerable degradations of the PSF. These problems are caused by a drifting of the satellite attitude due to thermal distortion of the side panel 7, where the attitude control system is mounted. We found that the position error averaged over a pointing observation can be largely reduced by using the relation between the deviation of the source position in the DETX direction and the ecliptic latitude of the pointing target. We parameterized the wobbling of the source position synchronized with the satellite orbital period with temperatures of onboard radiators and elapsed time since the night-day transition of the spacecraft. We developed software, aeattcor, to correct the image drift using these parameters, and applied it to 27 point-source images. We show that the radius of the 90% error circle of the source position was reduced to 19 arcsec and the PSF was sharpened. These improvements have enhanced the scientific capability of the Suzaku XIS.
We present the results of two XMM-Newton observations of the ultraluminous X-ray source (ULX) NGC 5204 X-1. The EPIC spectra are well-fit by the standard spectral model of a black-hole X-ray binary, comprising a soft multi-colour disc blackbody compo nent plus a harder power-law continuum. The cool (kT_in ~ 0.2 keV) inner-disc temperature required by this model favours the presence of an intermediate-mass black hole (IMBH) in this system, though we highlight a possible anomaly in the slope of the power-law continuum in such fits. We discuss the interpretation of this and other, non-standard spectral modelling of the data.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا