ترغب بنشر مسار تعليمي؟ اضغط هنا

A xenon gas purity monitor for EXO

96   0   0.0 ( 0 )
 نشر من قبل Carter Hall
 تاريخ النشر 2011
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We discuss the design, operation, and calibration of t



قيم البحث

اقرأ أيضاً

105 - A. Dobi , C. Hall , S. Slutsky 2011
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by th e presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We have used the technique to screen the EXO-200 xenon before, during, and after its use in our detector, and these measurements have proven useful. This is the first application of the cold trap mass spectrometry technique to an operating physics experiment.
Several efforts are ongoing for the development of spherical gaseous time projection chamber detectors for the observation of rare phenomena such as weakly interacting massive particles or neutrino interactions. The proposed detector, thanks to its s implicity, low energy threshold and energy resolution, could be used to observe the $betabeta0 u$ process i.e. the neutrinoless double beta decay. In this work, a specific setup is presented for the measurement of $betabeta0 u$ on 50~kg of $^{136}$Xe. The different backgrounds are studied, demonstrating the possibility to reach a total background per year in the detector mass at the level of 2 events per year. The obtained results are competitive with the present generation of experiments and could represent the first step of a more ambitious roadmap including the $betabeta0 u$ search with different gases with the same detector and therefore the same background sources. The constraints in terms of detector constructions and material purity are also addressed, showing that none of them represents a show stopper for the proposed experimental setup.
187 - S.Ban , K.D.Nakamura , S.Akiyama 2017
AXEL is a high pressure xenon gas TPC detector being developed for neutrinoless double-beta decay search. We use the proportional scintillation mode with a new electroluminescence light detection system to achieve high energy resolution in a large de tector. The detector also has tracking capabilities, which enable significant background rejection. To demonstrate our detection technique, we constructed a 10L prototype detector filled with up to 10bar xenon gas. The FWHM energy resolution obtained by the prototype detector is 4.0 $pm$ 0.30 $%$ at 122 keV, which corresponds to 0.9 ~ 2.0 % when extrapolated to the Q value of the $0 ubetabeta$ decay of $^{136}$Xe.
Within the framework of xenon-based double beta decay experiments, we propose the possibility to improve the background rejection of an electroluminescent Time Projection Chamber (EL TPC) by reducing the diffusion of the drifting electrons while keep ing nearly intact the energy resolution of a pure xenon EL TPC. Based on state-of-the-art microscopic simulations, a substantial addition of helium, around 10 or 15~%, may reduce drastically the transverse diffusion down to 2.5~mm/$sqrt{mathrm{m}}$ from the 10.5~mm/$sqrt{mathrm{m}}$ of pure xenon. The longitudinal diffusion remains around 4~mm/$sqrt{mathrm{m}}$. Light production studies have been performed as well. They show that the relative variation in energy resolution introduced by such a change does not exceed a few percent, which leaves the energy resolution practically unchanged. The technical caveats of using photomultipliers close to an helium atmosphere are also discussed in detail.
An experimental setup is being developed to extract Ba ions from a high-pressure Xe gas environment. It aims to transport Ba ions from 10 bar Xe to vacuum conditions. The setup utilizes a converging-diverging nozzle in combination with a radio-freque ncy (RF) funnel to move Ba ions into vacuum through the pressure drop of several orders of magnitude. This technique is intended to be used in a future multi-ton detector investigating double-beta decay in $^{136}$Xe. Efficient extraction and detection of Ba ions, the decay product of Xe, would allow for a background-free measurement of the $^{136}$Xe double-beta decay.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا