ترغب بنشر مسار تعليمي؟ اضغط هنا

Time-resolved charge detection in graphene quantum dots

87   0   0.0 ( 0 )
 نشر من قبل Johannes Guettinger
 تاريخ النشر 2011
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We present real-time detection measurements of electron tunneling in a graphene quantum dot. By counting single electron charging events on the dot, the tunneling process in a graphene constriction and the role of localized states are studied in detail. In the regime of low charge detector bias we see only a single time-dependent process in the tunneling rate which can be modeled using a Fermi-broadened energy distribution of the carriers in the lead. We find a non-monotonic gate dependence of the tunneling coupling attributed to the formation of localized states in the constriction. Increasing the detector bias above 2 mV results in an increase of the dot-lead transition rate related to back-action of the charge detector current on the dot.

قيم البحث

اقرأ أيضاً

We report measurements on a graphene quantum dot with an integrated graphene charge detector. The quantum dot device consists of a graphene island (diameter approx. 200 nm) connected to source and drain contacts via two narrow graphene constrictions. From Coulomb diamond measurements a charging energy of 4.3 meV is extracted. The charge detector is based on a 45 nm wide graphene nanoribbon placed approx. 60 nm from the island. We show that resonances in the nanoribbon can be used to detect individual charging events on the quantum dot. The charging induced potential change on the quantum dot causes a step-like change of the current in the charge detector. The relative change of the current ranges from 10% up to 60% for detecting individual charging events.
We report on charge detection in electrostatically-defined quantum dot devices in bilayer graphene using an integrated charge detector. The device is fabricated without any etching and features a graphite back gate, leading to high quality quantum do ts. The charge detector is based on a second quantum dot separated from the first dot by depletion underneath a 150 nm wide gate. We show that Coulomb resonances in the sensing dot are sensitive to individual charging events on the nearby quantum dot. The potential change due to single electron charging causes a step-like change (up to 77 %) in the current through the charge detector. Furthermore, the charging states of a quantum dot with tunable tunneling barriers and of coupled quantum dots can be detected.
Single electron pumps are set to revolutionize electrical metrology by enabling the ampere to be re-defined in terms of the elementary charge of an electron. Pumps based on lithographically-fixed tunnel barriers in mesoscopic metallic systems and nor mal/superconducting hybrid turnstiles can reach very small error rates, but only at MHz pumping speeds corresponding to small currents of the order 1 pA. Tunable barrier pumps in semiconductor structures have been operated at GHz frequencies, but the theoretical treatment of the error rate is more complex and only approximate predictions are available. Here, we present a monolithic, fixed barrier single electron pump made entirely from graphene. We demonstrate pump operation at frequencies up to 1.4 GHz, and predict the error rate to be as low as 0.01 parts per million at 90 MHz. Combined with the record-high accuracy of the quantum Hall effect and proximity induced Josephson junctions, accurate quantized current generation brings an all-graphene closure of the quantum metrological triangle within reach. Envisaged applications for graphene charge pumps outside quantum metrology include single photon generation via electron-hole recombination in electrostatically doped bilayer graphene reservoirs, and for readout of spin-based graphene qubits in quantum information processing.
We present time-resolved charge sensing measurements on a GaAs double quantum dot with two proximal quantum point contact (QPC) detectors. The QPC currents are analyzed with cross-correlation techniques, which enables us to measure dot charging and d ischarging rates for significantly smaller signal-to-noise ratios than required for charge detection with a single QPC. This allows to reduce the current level in the detector and therefore the invasiveness of the detection process and may help to increase the available measurement bandwidth in noise-limited setups.
138 - C. Rossler , B. Kung , S. Droscher 2010
In order to employ solid state quantum dots as qubits, both a high degree of control over the confinement potential as well as sensitive charge detection are essential. We demonstrate that by combining local anodic oxidation with local Schottky-gates , these criteria are nicely fulfilled in the resulting hybrid device. To this end, a quantum dot with adjacent charge detector is defined. After tuning the quantum dot to contain only a single electron, we are able to observe the charge detector signal of the quantum dot state for a wide range of tunnel couplings.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا