ترغب بنشر مسار تعليمي؟ اضغط هنا

Measurement of the Double Beta Decay Half-life of 130Te with the NEMO-3 Detector

148   0   0.0 ( 0 )
 نشر من قبل Victor Tretyak
 تاريخ النشر 2011
  مجال البحث
والبحث باللغة English




اسأل ChatGPT حول البحث

This Letter reports results from the NEMO-3 experiment based on an exposure of 1275 days with 661g of 130Te in the form of enriched and natural tellurium foils. The double beta decay rate of 130Te is found to be greater than zero with a significance of 7.7 standard deviations and the half-life is measured to be T1/2 = (7.0 +/- 0.9(stat) +/- 1.1(syst)) x 10^{20} yr. This represents the most precise measurement of this half-life yet published and the first real-time observation of this decay.



قيم البحث

اقرأ أيضاً

315 - J.Argyriades , R.Arnold , C.Augier 2009
Using 9.4 g of Zr-96 and 1221 days of data from the NEMO-3 detector corresponding to 0.031 kg yr, the obtained 2vbb decay half-life measurement is [2.35 +/- 0.14(stat) +/- 0.16(syst)] x 10^19 yr. Different characteristics of the final state electrons have been studied, such as the energy sum, individual electron energy, and angular distribution. The 2v nuclear matrix element is extracted using the measured 2vbb half-life and is 0.049 +/- 0.002. Constraints on 0vbb decay have also been set.
The NEMO-3 experiment at the Modane Underground Laboratory has investigated the double-$beta$ decay of $^{48}{rm Ca}$. Using $5.25$ yr of data recorded with a $6.99,{rm g}$ sample of $^{48}{rm Ca}$, approximately $150$ double-$beta$ decay candidate e vents have been selected with a signal-to-background ratio greater than $3$. The half-life for the two-neutrino double-$beta$ decay of $^{48}{rm Ca}$ has been measured to be $T^{2 u}_{1/2},=,[6.4, ^{+0.7}_{-0.6}{rm (stat.)} , ^{+1.2}_{-0.9}{rm (syst.)}] times 10^{19},{rm yr}$. A search for neutrinoless double-$beta$ decay of $^{48}{rm Ca}$ yields a null result and a corresponding lower limit on the half-life is found to be $T^{0 u}_{1/2} > 2.0 times 10^{22},{rm yr}$ at $90%$ confidence level, translating into an upper limit on the effective Majorana neutrino mass of $< m_{betabeta} > < 6.0 - 26$ ${rm eV}$, with the range reflecting different nuclear matrix element calculations. Limits are also set on models involving Majoron emission and right-handed currents.
The primary goal of the GERmanium Detector Array (Gerda) experiment at the Laboratori Nazionali del Gran Sasso of INFN is the search for the neutrinoless double beta decay of Ge-76. High-purity germanium detectors made from material enriched in Ge-76 are operated directly immersed in liquid argon, allowing for a substantial reduction of the background with respect to predecessor experiments. The first 5.04 kg yr of data collected in Phase I of the experiment have been analyzed to measure the half-life of the neutrino-accompanied double beta decay of Ge-76. The observed spectrum in the energy range between 600 and 1800 keV is dominated by the double beta decay of Ge-76. The half-life extracted from Gerda data is T(1/2) = (1.84 +0.14 -0.10) 10^{21} yr.
In the double beta decay experiment NEMO~3 a precise knowledge of the background in the signal region is of outstanding importance. This article presents the methods used in NEMO~3 to evaluate the backgrounds resulting from most if not all possible o rigins. It also illustrates the power of the combined tracking-calorimetry technique used in the experiment.
Double-beta decays of $^{100}$Mo from the 6.0195-year exposure of a 6.914 kg high-purity sample were recorded by the NEMO-3 experiment that searched for neutrinoless double-beta decays. These ultra-rare transitions to $^{100}$Ru have a half-life of a pproximately $7times10^{18}$ years, and have been used to conduct the first ever search for periodic variations of this decay mode. The Lomb-Scargle periodogram technique, and its error-weighted extension, were employed to look for periodic modulations of the half-life. Monte Carlo modeling was used to study the modulation sensitivity of the data over a broad range of amplitudes and frequencies. Data show no evidence of modulations with amplitude greater than 2.5% in the frequency range of $0.33225,{rm y^{-1}}$ to $365.25,{rm y^{-1}}$.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا