ترغب بنشر مسار تعليمي؟ اضغط هنا

Development and evaluation of 10-inch Photo-Multiplier Tubes for the Double Chooz experiment

118   0   0.0 ( 0 )
 نشر من قبل Takeo Kawasaki
 تاريخ النشر 2011
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The goal of Double Chooz experiment is a precise measurement of the last unknown mixing angle theta_13 using two identical detectors placed at far and near sites from Chooz reactor cores. The detector is optimized for reactor-neutrino detection using specially developed 10-inch PMTs. We developed two types of measurement systems and evaluated 400 PMTs before the installation. Those PMTs fulfill our requirements, and a half of those have been installed to the far detector in 2009. The character and performance data of the PMTs are stored in a database and will be referenced in analysis and MC simulation.

قيم البحث

اقرأ أيضاً

The Double Chooz experiment measures the neutrino mixing angle $theta_{13}$ by detecting reactor $bar{ u}_e$ via inverse beta decay. The positron-neutron space and time coincidence allows for a sizable background rejection, nonetheless liquid scintil lator detectors would profit from a positron/electron discrimination, if feasible in large detector, to suppress the remaining background. Standard particle identification, based on particle dependent time profile of photon emission in liquid scintillator, can not be used given the identical mass of the two particles. However, the positron annihilation is sometimes delayed by the ortho-positronium (o-Ps) metastable state formation, which induces a pulse shape distortion that could be used for positron identification. In this paper we report on the first observation of positronium formation in a large liquid scintillator detector based on pulse shape analysis of single events. The o-Ps formation fraction and its lifetime were measured, finding the values of 44$%$ $pm$ 12$%$ (sys.) $pm$ 5$%$ (stat.) and $3.68$ns $pm$ 0.17ns (sys.) $pm$ 0.15ns (stat.) respectively, in agreement with the results obtained with a dedicated positron annihilation lifetime spectroscopy setup.
134 - Kun Jiang , Zebo Tang , Xin Li 2020
The Large High-Altitude Air Shower Observatory (LHAASO) is being built at Haizi Mountain, Sichuan province of China at an altitude of 4410 meters. One of its main goals is to survey the northern sky for very-high-energy gamma ray sources via its grou nd-based water Cherenkov detector array (WCDA). 900 8-inch photomultiplier tubes (PMTs) CR365-02-1 from Beijing Hamamatsu Photon Techniques INC. (BHP) are installed in the WCDA, collecting Cherenkov photons produced by air shower particles crossing water. The design of the PMT base with a high dynamic range for CR365-02-1, the PMT batch test system, and the test results of 997 PMTs are presented in this paper.
During the commissioning of the first of the two detectors of the Double Chooz experiment, an unexpected and dominant background caused by the emission of light inside the optical volume has been observed. A specific study of the ensemble of phenomen a called Light Noise has been carried out in-situ, and in an external laboratory, in order to characterize the signals and to identify the possible processes underlying the effect. Some mechanisms of instrumental noise originating from the PMTs were identified and it has been found that the leading one arises from the light emission localized on the photomultiplier base and produced by the combined effect of heat and high voltage across the transparent epoxy resin covering the electric components. The correlation of the rate and the amplitude of the signal with the temperature has been observed. For the first detector in operation the induced background has been mitigated using online and offline analysis selections based on timing and light pattern of the signals, while a modification of the photomultiplier assembly has been implemented for the second detector in order to blacken the PMT bases.
80 - Chuanya Cao , Jilei Xu , Miao He 2021
26,000 3-inch photomultiplier tubes (PMTs) have been produced for Jiangmen Underground Neutrino Observatory (JUNO) by the Hainan Zhanchuang Photonics Technology Co., Ltd (HZC) company in China and passed all acceptance tests with only 15 tubes reject ed. The mass production began in 2018 and elapsed for about 2 years at a rate of $sim$1,000~PMTs per month. The characterization of the PMTs was performed in the factory concurrently with production as a joint effort between HZC and JUNO. Fifteen performance parameters were tracked at different sampling rates, and novel working strategies were implemented to improve quality assurance. This constitutes the largest sample of 3-inch PMTs ever produced and studied in detail to date.
Modern precision neutrino experiments like Double Chooz require a highly efficient trigger system in order to reduce systematic uncertainties. The trigger and timing system of the Double Chooz experiment was designed according to this goal. The Doubl e Chooz trigger system is driven by the basic idea of triggering on multiple thresholds according to the total visible energy and additionally triggering on the number of active photomultiplier tubes (PMTs) in the detector. To do so, the trigger system continuously monitors the analogue signals from all PMTs in the detector. The amplitudes of these PMT-signals are summed for groups of certain PMTs (group signals) and for all PMTs (sum signal), respectively. The group signals are discriminated by two thresholds for each input channel and four thresholds for the sum signal. The resulting signals are processed by the trigger logic unit which is implemented in a FPGA. In addition to the proper trigger, the trigger system provides a common clock signal for all subsequent data acquisition systems to guarantee a synchronous readout of the Double Chooz detectors. The present design of the system provides a high flexibility for the applied logic and settings, making it useful for experiments other than Double Chooz. The Double Chooz trigger and timing system was installed and commissioned in 2011. This article describes the hardware of the trigger and timing system. Furthermore the setup, implemented trigger logic and performance of the trigger and timing system for the Double Chooz experiment is presented.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا