ﻻ يوجد ملخص باللغة العربية
A prototype particle tracking telescope has been constructed using Timepix and Medipix ASIC hybrid pixel assemblies as the six sensing planes. Each telescope plane consisted of one 1.4 cm2 assembly, providing a 256x256 array of 55 micron square pixels. The telescope achieved a pointing resolution of 2.3 micron at the position of the device under test. During a beam test in 2009 the telescope was used to evaluate in detail the performance of two Timepix hybrid pixel assemblies; a standard planar 300 micron thick sensor, and 285 micron thick double sided 3D sensor. This paper describes a detailed charge calibration study of the pixel devices, which allows the true charge to be extracted, and reports on measurements of the charge collection characteristics and Landau distributions. The planar sensor achieved a best resolution of 4.0 micron for angled tracks, and resolutions of between 4.4 and 11 micron for perpendicular tracks, depending on the applied bias voltage. The double sided 3D sensor, which has significantly less charge sharing, was found to have an optimal resolution of 9.0 micron for angled tracks, and a resolution of 16.0 micron for perpendicular tracks. Based on these studies it is concluded that the Timepix ASIC shows an excellent performance when used as a device for charged particle tracking.
The Timepix particle tracking telescope has been developed as part of the LHCb VELO Upgrade project, supported by the Medipix Collaboration and the AIDA framework. It is a primary piece of infrastructure for the VELO Upgrade project and is being used
In the context of the 2013 APS-DPF Snowmass summer study conducted by the U.S. HEP community, this white paper outlines a roadmap for further development of Micro-pattern Gas Detectors for tracking and muon detection in HEP experiments. We briefly di
We present the first proof-of-concept simulations of detectors using biomaterials to detect particle interactions. The essential idea behind a DNA detector involves the attachment of a forest of precisely-sequenced single or double-stranded nucleic a
We present the design principle and test results of a data transmitting ASIC, GBS20, for particle physics experiments. The goal of GBS20 will be an ASIC that employs two serializers each from the 10.24 Gbps lpGBT SerDes, sharing the PLL also from lpG
The results obtained in laboratory tests, using scintillator bars read by silicon photomultipliers are reported. The present approach is the first step for designing a precision tracking system to be placed inside a free magnetized volume for the cha