ترغب بنشر مسار تعليمي؟ اضغط هنا

Design and application of robust rf pulses for toroid cavity NMR spectroscopy

45   0   0.0 ( 0 )
 نشر من قبل Thomas Skinner
 تاريخ النشر 2010
  مجال البحث فيزياء
والبحث باللغة English
 تأليف Thomas E. Skinner




اسأل ChatGPT حول البحث

We present robust radio frequency (rf) pulses that tolerate a factor of six inhomogeneity in the B1 field, significantly enhancing the potential of toroid cavity resonators for NMR spectroscopic applications. Both point-to-point (PP) and unitary rotation (UR) pulses were optimized for excitation, inversion, and refocusing using the gradient ascent pulse engineering (GRAPE) algorithm based on optimal control theory. In addition, the optimized parameterization (OP) algorithm applied to the adiabatic BIR-4 UR pulse scheme enabled ultra-short (50 microsec) pulses with acceptable performance compared to standard implementations. OP also discovered a new class of non-adiabatic pulse shapes with improved performance within the BIR-4 framework. However, none of the OP-BIR4 pulses are competitive with the more generally optimized UR pulses. The advantages of the new pulses are demonstrated in simulations and experiments. In particular, the DQF COSY result presented here represents the first implementation of 2D NMR spectroscopy using a toroid probe.

قيم البحث

اقرأ أيضاً

We present highly robust, optimal control-based shaped pulses designed to replace all 90{deg} and 180{deg} hard pulses in a given pulse sequence for improved performance. Special attention was devoted to ensuring that the pulses can be simply substit uted in a one-to-one fashion for the original hard pulses without any additional modification of the existing sequence. The set of four pulses for each nucleus therefore consists of 90{deg} and 180{deg} point-to-point (PP) and universal rotation (UR) pulses of identical duration. These 1 ms pulses provide uniform performance over resonance offsets of 20 kHz (1H) and 35 kHz (13C) and tolerate reasonably large radio frequency (RF) inhomogeneity/miscalibration of (+/-)15% (1H) and (+/-)10% (13C), making them especially suitable for NMR of small-to-medium-sized molecules (for which relaxation effects during the pulse are negligible) at an accessible and widely utilized spectrometer field strength of 600 MHz. The experimental performance of conventional hard-pulse sequences is shown to be greatly improved by incorporating the new pulses, each set referred to as the Fantastic Four (Fanta4).
Broadband inversion pulses that rotate all magnetization components 180 degrees about a given fixed axis are necessary for refocusing and mixing in high-resolution NMR spectroscopy. The relative merits of various methodologies for generating pulses s uitable for broadband refocusing are considered. The de novo design of 180 degree universal rotation pulses using optimal control can provide improved performance compared to schemes which construct refocusing pulses as composites of existing pulses. The advantages of broadband universal rotation by optimized pulses (BURBOP) are most evident for pulse design that includes tolerance to RF inhomogeneity or miscalibration. We present new modifications of the optimal control algorithm that incorporate symmetry principles and relax conservative limits on peak RF pulse amplitude for short time periods that pose no threat to the probe. We apply them to generate a set of pulses suitable for widespread use in Carbon-13 spectroscopy on the majority of available probes.
62 - Mikkel Tang 2021
Lasing in the bad cavity regime has promising applications in precision metrology due to the reduced sensitivity to cavity noise. Here we investigate the spectral properties and phase behavior of pulsed lasing on the $^1$S$_0 - ^3$P$_1$ line of $^{88 }$Sr in a mK thermal ensemble, as first described in arxiv:1903.12593. The system operates in a regime where the Doppler-broadened atomic transition linewidth is several times larger than the cavity linewidth. We find that by detuning the cavity resonance, the influence of the cavity noise on the peak lasing frequency can be eliminated to first order despite the system not being deep in the bad cavity regime. Experimental results are compared to a model based on a Tavis-Cummings Hamiltonian, which enables us to investigate the interplay between different thermal velocity classes as the underlying mechanism for the reduction in cavity noise. These velocity-dependent dynamics can occur in pulsed lasing and during the turn-on behavior of lasers in the superradiant crossover regime.
Probing an atomic resonance without disturbing it is an ubiquitous issue in physics. This problem is critical in high-accuracy spectroscopy or for the next generation of atomic optical clocks. Ultra-high resolution frequency metrology requires sophis ticated interrogation schemes and robust protocols handling pulse length errors and residual frequency detuning offsets . This review reports recent progress and perspective in such schemes, using sequences of composite laser-pulses tailored in pulse duration, frequency and phase, inspired by NMR techniques and quantum information processing. After a short presentation of Rabi technique and NMR-like composite pulses allowing efficient compensation of electromagnetic field perturbations to achieve robust population transfers, composite laser-pulses are investigated within Ramseys method of separated oscillating fields in order to generate non-linear compensation of probe-induced frequency shifts. Laser-pulses protocols such as Hyper-Ramsey (HR), Modified Hyper-Ramsey (MHR), Generalized Hyper-Ramsey (GHR) and hybrid schemes are reviewed. These techniques provide excellent protection against both probe induced light-shift perturbations and laser intensity variations. More sophisticated schemes generating synthetic frequency-shifts are presented. They allow to reduce or completely eliminate imperfect correction of probe-induced frequency-shifts even in presence of decoherence due to the laser line-width. Finally, two universal protocols are presented which provide complete elimination of probe-induced frequency shifts in the general case where both decoherence and relaxation dissipation effects are present by using exact analytic expressions for phase-shifts and the clock frequency detuning. These techniques might be applied to atomic, molecular and nuclear frequency metrology, mass spectrometry as well as precision spectroscopy.
Precise qubit manipulation is fundamental to quantum computing, yet experimental systems generally have stray coupling between the qubit and the environment, which hinders the necessary high-precision control. We report here the first theoretical pro gress in correcting an important class of errors stemming from fluctuations in the magnetic field gradient, in the context of the singlet-triplet spin qubit in a semiconductor double quantum dot. These errors are not amenable to correction via control techniques developed in other contexts, since here the experimenter has precise control only over the rotation rate about the z-axis of the Bloch sphere, and this rate is furthermore restricted to be positive and bounded. Despite these strong constraints, we construct simple electrical pulse sequences that, for small gradients, carry out z-axis rotations while canceling errors up to the sixth order in gradient fluctuations, and for large gradients, carry out arbitrary rotations while canceling the leading order error.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا