ترغب بنشر مسار تعليمي؟ اضغط هنا

Calibrating the correlation between black hole mass and X-ray variability amplitude: X-ray only black hole mass estimates for active galactic nuclei and ultra-luminous X-ray sources

150   0   0.0 ( 0 )
 نشر من قبل Xinlin Zhou
 تاريخ النشر 2009
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

A calibration is made for the correlation between the X-ray Variability Amplitude (XVA) and Black Hole (BH) mass. The correlation for 21 reverberation-mapped Active Galactic Nuclei (AGN) appears very tight, with an intrinsic dispersion of 0.20 dex. The intrinsic dispersion of 0.27 dex can be obtained if BH masses are estimated from the stellar velocity dispersions. We further test the uncertainties of mass estimates from XVAs for objects which have been observed multiple times with good enough data quality. The results show that the XVAs derived from multiple observations change by a factor of 3. This means that BH mass uncertainty from a single observation is slightly worse than either reverberation-mapping or stellar velocity dispersion measurements; however BH mass estimates with X-ray data only can be more accurate if the mean XVA value from more observations is used. Applying this relation, the BH mass of RE J1034+396 is found to be $4^{+3}_{-2} times 10^6$ $M_{odot}$. The high end of the mass range follows the relationship between the 2$f_0$ frequencies of high-frequency QPO and the BH masses derived from the Galactic X-ray binaries. We also calculate the high-frequency constant $C= 2.37 M_odot$ Hz$^{-1}$ from 21 reverberation-mapped AGN. As suggested by Gierlinski et al., $M_{rm BH}=C/C_{rm M}$, where $C_{rm M}$ is the high-frequency variability derived from XVA. Given the similar shape of power-law dominated X-ray spectra in ULXs and AGN, this can be applied to BH mass estimates of ULXs. We discuss the observed QPO frequencies and BH mass estimates in the Ultra-Luminous X-ray source M82 X-1 and NGC 5408 X-1 and favor ULXs as intermediate mass BH systems (abridged).



قيم البحث

اقرأ أيضاً

226 - Paul M. ONeill 2005
We have investigated the relationship between the 2-10 keV X-ray variability amplitude and black hole mass for a sample of 46 radio-quiet active galactic nuclei observed by ASCA. Thirty-three of the objects in our sample exhibited variability over a time-scale of ~40 ks, and we found a significant anti-correlation between excess variance and mass. Unlike most previous studies, we have quantified the variability using nearly the same time-scale for all objects. Moreover, we provide a prescription for estimating the uncertainties in excess variance which accounts both for measurement uncertainties and for the stochastic nature of the variability. We also present an analytical method to predict the excess variance from a model power spectrum accounting for binning, sampling and windowing effects. Using this, we modelled the variance-mass relation assuming all objects have a universal twice-broken power spectrum, with the position of the breaks being dependent on mass. This accounts for the general form of the relationship but there is considerable scatter. We investigated this scatter as a function of the X-ray photon index, luminosity and Eddington ratio. After accounting for the dependence of excess variance on mass, we find no significant correlation with either luminosity or X-ray spectral slope. We do find an anti-correlation between excess variance and the Eddington ratio, although this relation might be an artifact owing to the uncertainties in the mass measurements. It remains to be established that enhanced X-ray variability is a property of objects with steep X-ray slopes or large Eddington ratios.
238 - Xin-Lin Zhou 2014
Ultra-luminous X-ray sources (ULXs) are off-nuclear X-ray sources in nearby galaxies with X-ray luminosities $geq$ 10$^{39}$ erg s$^{-1}$. The measurement of the black hole (BH) masses of ULXs is a long-standing problem. Here we estimate BH masses in a sample of ULXs with XMM-Newton observations using two different mass indicators, the X-ray photon index and X-ray variability amplitude based on the correlations established for active galactic nuclei (AGNs). The BH masses estimated from the two methods are compared and discussed. We find that some extreme high-luminosity ($L_{rm X} >5times10^{40}$ erg s$^{-1}$) ULXs contain the BH of 10$^{4}$-10$^{5}$ $M_odot$. The results from X-ray variability amplitude are in conflict with those from X-ray photon indices for ULXs with lower luminosities. This suggests that these ULXs generally accrete at rates different from those of X-ray luminous AGNs, or they have different power spectral densities of X-ray variability. We conclude that most of ULXs accrete at super-Eddington rate, thus harbor stellar-mass BH.
118 - Yuan Liu , Shuang Nan Zhang 2008
Aims. Both the black hole mass and the X-ray luminosity of AGNs have been found to be anti-correlated with the normalized excess variance ($sigma_{rm rms}^2 $) of the X-ray light curves. We investigate which correlation with $sigma_{rm rms}^2 $ is th e intrinsic one. Methods. We divide a full sample of 33 AGNs (O Neill et al. 2005) into two sub-samples. The black hole masses of 17 objects in sub-sample 1 were determined by the reverberation mapping or the stellar velocity dispersion. The black hole masses of the remaining 16 objects were estimated from the relationship between broad line region radius and optical luminosity (sub-sample 2). Then partial correlation analysis, ordinary least squares regression and K-S tests are performed on the full sample and the sub-samples, respectively. Results. We find that $sigma_{rm rms}^2 $ seems to be intrinsically correlated with the black hole mass in the full sample. However, this seems to be caused by including the sub-sample 2 into the analysis, which introduces an extra correlation between the black hole mass and the luminosity and strengthens any correlation with the black hole mass artificially. Therefore, the results from the full sample may be misleading. The results from the sub-sample 1 show that the correlation between $sigma_{rm rms}^2 $ and the X-ray luminosity may be the intrinsic one and therefore the anti-correlation between $sigma_{rm rms}^2 $ and the black hole mass is doubtful.
123 - B. De Marco , G. Ponti , M. Cappi 2011
We carried out a systematic analysis of time lags between X-ray energy bands in a large sample (32 sources) of unabsorbed, radio quiet active galactic nuclei (AGN), observed by XMM-Newton. The analysis of X-ray lags (up to the highest/shortest freque ncies/time-scales), is performed in the Fourier-frequency domain, between energy bands where the soft excess (soft band) and the primary power law (hard band) dominate the emission. We report a total of 15 out of 32 sources displaying a high frequency soft lag in their light curves. All 15 are at a significance level exceeding 97 per cent and 11 are at a level exceeding 99 per cent. Of these soft lags, 7 have not been previously reported in the literature, thus this work significantly increases the number of known sources with a soft/negative lag. The characteristic time-scales of the soft/negative lag are relatively short (with typical frequencies and amplitudes of usim 0.07-4 times 10^{-3} Hz and tausim 10-600 s, respectively), and show a highly significant (gsim 4sigma) correlation with the black hole mass. The measured correlations indicate that soft lags are systematically shifted to lower frequencies and higher absolute amplitudes as the mass of the source increases. To first approximation, all the sources in the sample are consistent with having similar mass-scaled lag properties. These results strongly suggest the existence of a mass-scaling law for the soft/negative lag, that holds for AGN spanning a large range of masses (about 2.5 orders of magnitude), thus supporting the idea that soft lags originate in the innermost regions of AGN and are powerful tools for testing their physics and geometry.
The mass transfer in binaries with massive donors and compact companions, when the donors rapidly evolve after their main sequence, is one of the dominant formation channels of merging double stellar-mass black hole binaries. This mass transfer was p reviously postulated to be unstable and was expected to lead to a common envelope event. The common envelope event then would end with either double black hole formation, or with the merger of the two stars. We re-visit the stability of this mass transfer, and find that for a large range of the binary orbital separations this mass transfer is stable. This newly found stability allows us to reconcile the theoretical rate for double black hole binary mergers predicted by population synthesis studies, and the empirical rate obtained by LIGO. Futhermore, the stability of the mass transfer leads to the formation of ultra-luminous X-ray sources. The theoretically predicted formation rates of ultra-luminous X-ray sources powered by a stellar-mass BH, as well as the range of produced X-ray luminosity, can explain the observed bright ultra-luminous X-ray sources.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا